提供7*24专业Sybase数据库远程及现场技术支持,Sybase ASE及Sybase SQL Anywhere数据库修复服务,
请联系电话: (微信),QQ: 289965371!
We supply technical support for Sybase ASE and Sybase SQL Anywhere, also have many years of experience in recovering data from damanged Sybase devices.
Please contact us:
Phone:
Wechat: 13811580958
QQ: 289965371 联系我们获取数据库技术支持!
Email: 289965371@qq.com
扫描下方微信,联系我们:
扫描雨翰数据恢复官方微信获取专业数据库恢复服务

 

随着Sybase被完全整合到SAP下,Sybase原来的支持网站被SAP Support Portal取代。
只有购买了SAP服务的用户才能使用账号登录SAP Support Portal进行介质下载、补丁升级、报Incident等。
考虑到Sybase数据库的初学者或者没有购买原厂服务的Sybase客户情况,现提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息。
在SAP Support Portal网站或者google上搜索Targeted CR List for ASE,可以看到针对不同版本的CR(CR表示Change Request)简单描述信息列表。
需要注意的是:Targeted CR List for ASE列出的CR虽然绝大多数是BUG,但有一些是更改需求。
以下提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息!

如有问题,请联系我!

QQ :289965371 联系我们获取数据库技术支持!
Email:
不仅仅包括BUG的详细描述信息,还包括首次报告BUG的平台、数据库版本以及BUG修复历史过程;有些BUG还提供了Workaround来临时解决该BUG带来问题。

 

CR:287896
CR Number:   287896
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.2 31 Jul 2002 Fixed
Description
Using Printpage() does not start a new page in PB 8.0.2 build 9506. Furthermore the print from the second page overwrites the print from the first page resulting in the print being garbled and unreadable.



CR:287900
CR Number:   287900
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
ENHANCEMENT request. Oracle supports the use of a RETURNING clause for the INSERT statement. The developer can code an insert trigger that pops a sequence and uses it to populate the 'autoincrementing' column. The developer can then set this column in the datawindow update specs. During the update, simply add "RETURNING <autoincrementingcolumn> INTO :abindvariable" and then use the result returned into that bind variable to populate the column in the datawindow for that row.



CR:288015
CR Number:   288015
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Aug 2002 Not a Bug
Description
You can drag the column outside the veiwable area and the scrollbar will not appear, which means that you will not be able to get the column back to the viewable area again.



PSE - 8/26/2002 - Per development, this cr is not a bug, and the product behavior will not be changed because of the risks and complexity of the request.



The following is a workaround of modifying the width and height of the dw control and triggering the resize event. In order for this to work, use:



dw_1.modify('create text(band=detail alignment="0" text="NEW TEXT" border="2" color="0" x="1111" y="4" height="64" width="11334" font.face="Arial" font.height="-10" font.weight="400" font.family="2" font.pitch="2" font.charset="0" background.mode="1" background.color="536870912" moveable=1 )')



dw_1.height=dw_1.height + 5

dw_1.width=dw_1.width + 200

dw_1.height=dw_1.height - 5

dw_1.width=dw_1.width - 200

dw_1.triggerevent(resize!)



CR:288031
CR Number:   288031
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 25 Feb 2004 Fixed
Description
PB Jaguar component using SYJ interface connecting to ASE 12, gets 4023 error. SYC connections in PB do not get this error. (User password will expire soon).



CR:288033
CR Number:   288033
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.2 14 May 2003 Fixed
Description
Since upgrading to PB 8.02 setting print.filename property does not work with RTF datawindow when trying to print to a file. Return code is = to 1 but does not create the file.



CR:288078
CR Number:   288078
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Customers would like to get a tool/enhancement in the current PB GUI or Jaguar Manager GUI to set up the library list of shared PBD files in Jaguar repository .props files. This is to help customers who are implementing memory related techniques as described in techdoc/whitepaper: http://www.sybase.com/detail?id=1019042



CR:288110
CR Number:   288110
Product Name:   PB Enterprise
Product Component:   DataBase
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB 9 Beta 2: Enhancement Request: Provide a way for DynamicDescriptionArea object to get the column name of each output parameter.



CR:288122
CR Number:   288122
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.3 11 Apr 2003 Fixed
Description
PB crashes when trying to delete the last row in a grid datawindow that is using ShareData with two other dws. This is similar to CR 262495 but in that case there were only a total of two datawindows using Sharedata and that is fixed in the build that this still fails with.



CR:288124
CR Number:   288124
Product Name:   PB Enterprise
Product Component:   MAPI
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Apr 2003 Presently Not Targeted For Any Future Release Of This Product
Description
MailMessage property ReceiptRequested not working.



April 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:288128
CR Number:   288128
Product Name:   PB Enterprise
Product Component:   Installation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
27 Sep 2002 Fixed
Description
PB9.0 Beta 2: Installation prompts for other products need consistency.



CR:288193
CR Number:   288193
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 Beta 4 16 Sep 2002 Fixed
Description
Cannot generate proxy from several *.wsdl files



CR:288206
CR Number:   288206
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Open
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
During a build, when an error message points to an object. It would be nice if two things could happen:



1. If I implement a fix in an object, it would be real nice if PB could determine whether the fix has an effect on other errors, and fix those

errors.

2. The error line points to a specific object. If I could right-mouse click on the error line and have an option for Regenerate which, if the error was fixed, would remove that particular error from the output window, maintaining my current position. This way I could go through an error list and fix errors one by one, Alternatively, give me the ability to generate todo list items directly from the output window.



CR:288207
CR Number:   288207
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Open
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
It would be nice to:



a) be able to suppress certain messages from the Output Window such as Rebuilding Type and Generating messages by object.

b) have a summary at the end that indicates how many errors were found for each type of error (warning, error).

c) Have a quick link to get back to the first error from this batch (if output window is not set to CLEAR, it concatenates. Get next error will

start at the beginning.

d) Be bale to automatically clear the output window conditionally (Full Rebuild or Deploy for example).



CR:288210
CR Number:   288210
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Open
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
When doing a full build and you get an error, one of three things can happen when you double-click on the error in the output window.



1. It opens the object that contains the error

2. It opens the source for the objct that contains the error.

3. It displays an error message indicating that the object has been

successuflly migrated but must be regenerated.



The first two options work very nicely, but I don't understand why the third one appears. Either open the source for the object, or, at the very least, position me in the System Tree to the object in question so the user does not have to go hunting for it.



CR:288214
CR Number:   288214
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10 Apr 2003 Fixed
25 Feb 2004 Fixed
Description
The return value from PrintWidth() is defined as an integer but a long is used in the help examples and in the Powerscript Reference Guide. It appears as though the actual return code is an integer but the example is misleading and needs to be changed. Should the return value really be a long or is the example wrong?



From the documentation the function: "Determines the width of a string using the current font of the specified print job. Returns the width of string in thousandths of an inch using the current font of rintjobnumber if it succeeds and -1 if an error occurs."



If the string width results in a number larger than the standard integer limit of +32767 ( 32+ * 1000) then the value that is returned is not accurate (integer overflow occurs) but no error is returned to the user. With the example using a long, customers would assume that the return value could be up +2,147483,647. This has resulted in at least one customer believing that they could parse a long string using this function.



So, either this is a bug and the return value needs to be changed to a long or if the return type is confirmed to be an integer, the example in the help files in PB and in the written documentation in the Powerscript Reference guide need to be changed.



CR:288219
CR Number:   288219
Product Name:   PB Enterprise
Product Component:   Install
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 Beta 3 04 Jul 2002 Fixed
Description
PB 9.0 Beta 2: Infomaker install puts PBO9090.DLL into the top level directory (e.g., Program Files/Sybase) versus in the Shared/PowerBuilder directory



CR:288254
CR Number:   288254
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 28 Nov 2002 Fixed
Description
Enhancement request to right-mouse-click on a library in the system tree and have an option to remove the library from the targets library list.



CR:288264
CR Number:   288264
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
This is a request to introduce a new datawindow modify function to inhibit the repeating of group headers during virtual scrolling.



CR:288313
CR Number:   288313
Product Name:   PB Enterprise
Product Component:   DW SaveAs
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 03 Sep 2002 Fixed
Description
A crash occurs when trying to save a crosstab datawindow that has a column of which the width of the column is too narrow. With a larger width the gpf does not occur.



This is a PowerBuilder 7.03 only regression in build 10100 and larger.

The problem did not occur in PowerBuilder 8.0.2 Build 9506.



CR:288389
CR Number:   288389
Product Name:   PB Enterprise
Product Component:   WT - Deployment
Status:   Closed
OS:   NT4
Original Version:   8.0 GA
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Dec 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Deploying web target to ASP on IIS doesn't create/modify GLOBAL.ASA



December 18, 2002

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:288396
CR Number:   288396
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Dec 2002 Presently Not Targeted For Any Future Release Of This Product
Description
In the datawindow when you have objects behind a groupbox, then these objects

are still responding to events like mouse move etc.



December 17, 2002

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:288407
CR Number:   288407
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Oct 2003 Presently Not Targeted For Any Future Release Of This Product
Description
MessageService : Cannot pass a blob from PB to Jaguar in a message

PB build 9224 and 9506

EAS 4.1.1



Using the CtsComponents/MessageService components in EAS.

When calling the publish method on the MessageService object

cms.publish(topic, msg, 0);

and one of the properties of the MessageObject (msg) is a Blob (from PB) or Byte (from Java) it fails with a CORBA.MARSHAL error :



May 20 12:00:36 2002: org.omg.CORBA.MARSHAL: read_string: length = 0 minor code: 0 completed: No

May 20 12:00:36 2002: at com.sybase.CORBA.iiop.InputStream.read_string(InputStream.java:317)

May 20 12:00:36 2002: at CtsComponents.MessageHelper.read(MessageHelper.java:20)

May 20 12:00:36 2002: at com.sybase.CORBA.cts._sk_CtsComponents_MessageService.invoke(_sk_CtsComponents_MessageService.java:539)

May 20 12:00:36 2002: SystemException: MARSHAL (CtsComponents/MessageService/publish - @158.76.131.47)
Review Status
 October 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:288429
CR Number:   288429
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Customer would like to have a 'Moveable' attribute for the dwcontrol. Currently, the dwcontrol is not moveable unless there is a titlebar. Would prefer if the 'moveable' and 'titlebar' attributes could be toggled separately.



CR:288450
CR Number:   288450
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Apr 2003 Presently Not Targeted For Any Future Release Of This Product
Description
When creating a datawindow using a stored procedure,

viewing a stored procedure in the "select stored procedure" view, is truncated.



The datawindow works ok. When selecting the stored procedure, the select box

will show the stored procedure that was just selected. Using the ASE ODBC driver,

the stored procedure is truncated in that view.



April '03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:288505
CR Number:   288505
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Nov 2002 Presently Not Targeted For Any Future Release Of This Product
Description
"Append HTML Syntax" ignored for "Display Only" columns with Opera and Netscape.
Review Status
 November 22, 2002

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".
Workaround Description
 Set Opera to act as Mozilla 5.0 e.g. same as Netscape 6.2 -> but the columns are not correctly marked as READONLY.



CR:288562
CR Number:   288562
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 Beta 2 29 Aug 2002 Fixed
Description
The new pbni90.hlp file has some inconsistencies.

In the "Changes between Beta 1 and Beta 2" topic, a change to the PBX_GetDescription method is described, however, the "PBNI application example" topic still uses the old syntax.



Also:

In the "Required methods in the PBNI module" topic, the signature of the PBX_GetDescription() function is wrong -- it is using a PBXRESULT returnvalue instead of an LPCTSTR:

PBXEXPORT PBXRESULT PBXCALL PBX_GetDescription(); // wrong

PBXEXPORT LPCTSTR PBXCALL PBX_GetDescription(); // right



CR:288646
CR Number:   288646
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   Microsoft Windows 2000
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
OLE object in the dw detail band that is dynamically linked to a Ms Word document for update. End-user is allowed to modify the doc contents but the retrieve does not pay attention to the new height and width oppositely to the design mode. Add a "Autosize Height" propertie to the OLE object so that it can be resized during runtime automaticly. At the moment it keeps the fix size it got during design time and can only resized manualy if the resize propetie is enabled.



CR:288663
CR Number:   288663
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 Beta 4 02 Aug 2002 Fixed
Description
This CR concerns PB installed database interfaces for Microsoft SQL Server database.



At this time PB7.x and PB8.x product releases support Microsoft SQL Server 6.x, 7.x and 2000 databases (see research section below). Thus the PB database profile dialog is incorrect because customer could have installed any of the supported MS SQL Server versions.

The db profile "Preview" tab shows the incorrect 'database connection syntax' and the trace utility documentation i.e. pbtrace.log would also be incorrect.



There are 2 areas in the graphical user interface where the text is misleading.

1)PB db profile dialog title displays:

Database profile setup - Microsoft SQL Server 6.x



b)Db profile "Preview" tab, the setting for SQLCA.DBMS displays:

SQLCA.DBMS = "MSS Microsoft SQL Server 6.x"



CR:288665
CR Number:   288665
Product Name:   PB Enterprise
Product Component:   DW DDDW
Status:   Open
OS:   Microsoft Windows 2000
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.2 08 Oct 2002 Fixed
Description
In a dw containing a DropDownDataWindow, destroy any column using Modify (leaving at least 1 col with a dddw) then call GetFullState + SetFullState -> PB 8.0x will crash on the call to SetFullState.



With PB 8.02 build 9596 the crash is ...

0x10bb02fb referenced memory @ 0x00000000 - memory could not be read



Some additional tests in PB 8.0x

- Destroy col + SetFullState (no dddw in dw) -> No data is passed

SetFullState returns 2 the

first time and 1 the next time



- Do not destroy col + dddw in the dw -> Works correctly



- Create dddw dynamically + destroy col + SetFullState -> Crash



In PB 7.0x the behaviour is the same except that instead of crashing it fails to pass the data to 2nd dw.



CR:288699
CR Number:   288699
Product Name:   PB Enterprise
Product Component:   Rich Text
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
19 Jul 2005 Not a Bug
Description
CopyRTF function returns high-bit characters encoded as a series of characters whereas previously(PowerBuilder 5 through 7.0.3) the actual characters were preserved in the returned string. Customer is using this string to parse and is using one of these high bit characters to determine what to replace.



CR:288769
CR Number:   288769
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Mar 2005 Fixed
09 Dec 2005 Third Party Problem
Description
Trying to create proxies for EJB 1.1 containing public static final String in home interface causes PB to GPF. Basically when there is a Datamember in the EJBs home, no matter if static, final etc. it will GPF PB.



CR:288834
CR Number:   288834
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0 GA
Fixed Version Build Resolution Date Closure Code (If Appropriate)
12 Feb 2003 Not a Bug
Description
Customer was unable to get the tutorial in

Getting Started

PowerBuilder 8.0 windows to work



If he changed the



Lesson 12 - Add a dataWindow to an existing Web page

page273, is incorrect. Customer reported that he needed to change the properties to use the Jaguar component and this solved issue.



Alternatively, I found that adding the PBL to the system path in order to get the tutorial to work.



CR:288864
CR Number:   288864
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.4 02 May 2005 Not reproducible with latest version of the product available as of Resolution Date
Description
REGRESSION If the the DW column with EditMask (string) is initialized by script the mask get corrupted. String column with a editmask xx-xxx-xx-xx-xxx will be modified with:

modify ( "column_name.initial = '432'"). This corrupt the editmask and you're unable to enter the complete values into the mask.(432- - - - ) without modify and (432----) after modify the inital property.



Workaround: use blanks in the initial string to fill the characters

modify ( "column_name.initial = '432 '")



CR:288918
CR Number:   288918
Product Name:   PB Enterprise
Product Component:   DB OLE DB
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 13 Aug 2002 Fixed
Description
Calling an SP with datetime output argument on MSSQL Server via SQLOLEDB connection, not passing DateTime back correctly.



CR:288980
CR Number:   288980
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 28 Oct 2002 Fixed
Description
PB 9.0 Beta2: Enable the F2 key (standard windows behavior) to rename the currently selected clip item in the ClipWindow.



CR:288992
CR Number:   288992
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 27 Sep 2002 Fixed
Description
PB 9.0 Beta2: No prompt to confirm deletion of item in ClipWindow



CR:289004
CR Number:   289004
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
The autoskip property of an editmask field on a datawindow does not work for web datawindows.



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289026
CR Number:   289026
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
01 Aug 2008 Insufficient priority to fix
Description
PB 9 Beta 1: SCC/PVCS: Cannot use VLOGIN authentication.



CR:289027
CR Number:   289027
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 09 Oct 2002 Fixed
Description
Triggering a parent user event from the doubleclicked event of a datawindow causes PowerBuilder build 9224 and 9601 to crash. The code worked with earlier builds.



Workaround: use PostEvent instead of TriggerEvent
Workaround Description
 Use PostEvent instead of TriggerEvent and the crash does not occur.



CR:289031
CR Number:   289031
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Nov 2002 Not a Bug
08 Oct 2003 Not a Bug
Description
RowFocus events not firing when clicking on non-editable column in row that has at least one editable field. Engineering has determined this is not a bug: "There are two different modes for viewing a DW -- Edit Mode and Read-only Mode. They have different rules and, therefore, different behaviors. But this is established behavior and it is better not to change it."



CR:289033
CR Number:   289033
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
01 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
If a limit value is set for a text column that is

greater than 32000, the value is reset to 32000.



Limit=0 means the maximum number. The text column limit should be able to be set up to

32767 (according to online help).



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".
Workaround Description
 Use limit=0 or dbparm (dbtextlimit).



CR:289045
CR Number:   289045
Product Name:   PB Enterprise
Product Component:   DB ODBC
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11 Dec 2002 Third Party Problem
Description
Cannot view tables using ODBC MS Text driver (ODBCJT32.DLL version 4.0.6019.0)



PowerBuilder Engineering found that the problem is in the ODBCJT32.DLL version 4.0.6019.0.

Earlier versions of this dll work. And with the newer version the same problem occurs in Visual Basic. So the problem is not with PowerBuilder. If possible go back to the earlier version of the ODBCJT32.DLL that works correctly. We found that version 3.51.1713.00 works correctly. If this is not possible then the following workaround should also allow you the access the files corretly:



1) Add a .txt extension to your files

2) Modify the schema.ini file so that the profiles reflect the .txt extension

3) Modify the pbodb70.ini to set PBTableDot=1

[Text ODBCJT16]

PBNoCatalog='YES'

PBSyntax='CORE_SYNTAX'

PBDateTime='DEFAULT_DATETIME'

DelimitIdentifier='YES'

PBFunctions='TEXT_FUNCTIONS'

PBTableDot=1



[Text ODBCJT32]

PBNoCatalog='YES'

PBSyntax='CORE_SYNTAX'

PBDateTime='DEFAULT_DATETIME'

DelimitIdentifier='YES'

PBFunctions='TEXT_FUNCTIONS'

PBTableDot=1



4) Modify the DB profile to uncheck "Enclose Table and Column Names

in Quotes" (or add following in connectstring: DelimitIdentifier='No').
Workaround Description
 The PB Merant Text Driver works fine.



CR:289111
CR Number:   289111
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
Application crashes when user runs, does a Save, and then clicks on a specific tab page.



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289159
CR Number:   289159
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
In the datawindow painter, typing in the Spin Min, Spin Max edit properties

doesn't work properly anymore since Build 10100 of PowerBuiler 7.

The problem is also in PowerBuilder 8.



CR:289174
CR Number:   289174
Product Name:   PB Enterprise
Product Component:   Rich Text
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 21 Aug 2002 Fixed
Description
In old PB 5.0, the rich text edit produced that resulted data correctly. After migrating app to 7.0.x, the rich text fields are displayed as ????.



CR:289190
CR Number:   289190
Product Name:   PB Enterprise
Product Component:   DW Rich Text
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 May 2003 Fixed
Description
Richtext datawindow data is not displayed if retrieving data at runtime. Development datawindow preview works fine all the time.



No Workaround
Workaround Description
 none



CR:289197
CR Number:   289197
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
Inserting an OLE object in a detail band of a DW causes GPF. In PowerBuilder 7 this happens when preview mode is checked and 'Retain Data to Design' is unchecked.

This also happens when Retriev on Preview is enabled in the painter, but no rows are yet

retireved.



Workaround:

Either close the preview window, or retrieve the rows first when creating the ole object.



CR:289202
CR Number:   289202
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Oct 2003 Presently Not Targeted For Any Future Release Of This Product
Description
This problem appears to be platform specific. This feature is broken for Wintel 9x operating systems and behaving correctly for Windows NT and Windows 2000 operating systems.



The problem occurs if the datawindow has got focus and then the user clicks on another editable control on the window object e.g. singlelineedit, multilineedit, editmask or RichTextEdit. The powerscript in the new control getfocus event does not get triggered.
Review Status
 October 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289221
CR Number:   289221
Product Name:   PB Enterprise
Product Component:   Menu Painter
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
The problem occurs in the menu painter if keyboard arrow keys are used to scroll for a ToolbarItemName icon.



Sometimes Powerbuilder software does abort and causes screen display distortion problems in the other open window applications (possible memory leak).



Workaround:

Use mouse buttons to vertical scroll and select a ToolbarItemName icon instead of keyboard arrow keys to select choice of icon from dropdownlistbox.



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289243
CR Number:   289243
Product Name:   PB Enterprise
Product Component:   DW Synchronization
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
01 Aug 2002 Fixed
Description
PowerBuilder 8.02 only regression

Applying RowsMove with as target a shared datawindow

can cause a crash.

Work-around is to remove the share before the RowsMove()



CR:289277
CR Number:   289277
Product Name:   PB Enterprise
Product Component:   Edit Mask
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.2 12 Aug 2002 Fixed
14 May 2003 Fixed
Description
EditMask control with Mask hh:mm am/pm and MaskDataType TimeMask! and calling the string( now(),"hh:mm AM/PM") function shows all time as AM.



CR:289296
CR Number:   289296
Product Name:   PB Enterprise
Product Component:   DW Plugin
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
A psr report will not display in a Netscape

browser when dragged/dropped onto the browser.



CR:289354
CR Number:   289354
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
When a column in a datawindow has autosize height checked, a border and initially does not have any text in the column the border does not show. This behavior presents a very unprofessional looking data entry screen to the end user. Once text is input to the column and one tabs away the border is visible. Inserting spaces does not force the border to display.



This behavior was seen in all versions and builds of PB 7/8/9 tested and this may turn out to be either a documentation issue and/or an enhancement request.



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289357
CR Number:   289357
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
When a column in a datawindow has autosize height checked, and the user is inputting text into the column he/she only sees one line of text until the entire text is input and one tabs off the column. This current behavior produces an unprofessional looking application.



Please change the behavior so that one can see the entire text while inputting. Please also change the behavior so that one does not have to do a setRedraw() before and after the text is input to have the columns below this redraw once text is input.



This behavior was seen in all versions and builds of PB 7/8/9 tested and this may turn out to be either a documentation issue and/or an enhancement request.



CR:289373
CR Number:   289373
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
When a column in a datawindow has autosize height checked and the size exceeds the initial size the columns below this do not redraw without the use of SetRedraw(). Display is garbled until one clicks back into the autosized column.



This behavior was seen in all versions and builds of PB 7/8/9 tested and this may turn out to be either a documentation issue and/or an enhancement request.



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289403
CR Number:   289403
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 Jul 2002 Fixed
Description
Cannot add pbd to library path in the system tree.

Right mouse click on target, selected properties. The ddlb, only shows *.pbl.





Uninstalled beta2 and installed PB 9.0 beta 3 (build 3501) that is when the

problem appeared.



CR:289466
CR Number:   289466
Product Name:   PB Enterprise
Product Component:   Printing
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Jan 2003 Presently Not Targeted For Any Future Release Of This Product
Description
When the control is not fully displayed on the window and OriginalSize property checked (or unchecked - no difference), the output printed is wrong. It prints the part of the image and the outside region as a screenshot in the size of the original picture.



January 14, 2003

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".
Workaround Description
 Use PrintBitmap function if possible.



CR:289471
CR Number:   289471
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 01 Oct 2002 Fixed
Description
Filter and other events are not triggered if using DCUBE OCX in PB 8 enviroment.

if using the dropdown listboxed (for instance "department" and uncheck "Admin")

the filter of the "Admin" part of the datasheet does not work.



No Workaround
Workaround Description
 non



CR:289495
CR Number:   289495
Product Name:   PB Enterprise
Product Component:   DW Graph
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.2 14 May 2003 Fixed
Description
Versions and Build #s Reported: PB8 Build 9242, 9242, 9608; PB7 10197

Versions and Build #s Tested: PB8 Build 9121 OK; PB7 10193 OK



1) The markers both in the datawindow graph and in the legend are no longer in colour, but are drawn in black.



2) For the top series no line is drawn where they should be one. This series has no first

point which may be related.



Both problems where found in PB8.0.2 Build 9242, 9242, 9608

Only the second issue was found in PB7 Build 10197.



CR:289502
CR Number:   289502
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 22 Aug 2002 Duplicate
Description
nested select "SELECT * FROM (SELECT sys.all_users.username,0 FROM sys.all_users)" causes database error "Select error:" if retrieve as needed is activated. nested SELECT * FROM (SELECT 0,sys.all_users.username FROM sys.all_users) is working fine



workaround: diable "retrieve as needed"
Workaround Description
 disable "retrieve as needed"



CR:289510
CR Number:   289510
Product Name:   PB Enterprise
Product Component:   JSP Deployment
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Jul 2002 Duplicate
Description
Deploying a war file containing a jsp page results in the

following error:



---------- Deploy: Deploy of target Target1

Target1DeployConfiguration1:

Building...

Target1 - 0 error(s), 0 warning(s)

Deploying...

Generating WAR File...

Delivering WAR File...

Deployment Successful - c:\TEMP\Target1.war WebApplication Target1 was successfully installed into Server Jaguar

Target1 Deployed - 0 error(s), 0 warning(s)

DeployConfiguration2:

Building...

Untitled.jsp

web.xml

Target1 - 0 error(s), 0 warning(s)

Deploying...

Error: Could not create file.

Target1 Deployed - 1 error(s), 0 warning(s)

---------- Finished Deploy of target Target1





In JagManager, the Webapplication of Target1 shows up, but the jsp page does not.

Checking the Repository, the jsp is installed under the webapplication folder.



Tried deploying the war file using the jagtool, results in the same problem.

Jagtool will return that the "WebApplication Target1 was successfully installed into

Server manager", but the jsp page does not show up in JagManager.



CR:289533
CR Number:   289533
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
DWs created with Oracle 7.x ODBC using ANSI outer join syntax don't work in Oracle 8.x. The SQL generates an error.



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289619
CR Number:   289619
Product Name:   PB Enterprise
Product Component:   DB Sybase System
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 01 Nov 2002 Fixed
Description
PowerBuilder 6.5 or later:

When using a number coltype column to retrieve or update a decimal column in an

ASE database then the fractional part gets lost.

This happens using the native SYC driver, but not when using ODBC.

When the datawindow painter creates the datawindow, then it will create it with

coltype decimal(..) not with coltype number.



CR:289628
CR Number:   289628
Product Name:   PB Enterprise
Product Component:   ORCA
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Oct 2002 Fixed
Description
Six ORCA functions are no longer supported by PB 9. They need to be documented. These are:

CheckOutInfo

CheckOutPreview

ORCA_CheckInEntry

ORCA_CheckOutEntry

ORCA_CheckOutEntryList

ORCA_CheckOutPreview

Comments:

In the ORCA PB 9.0 doc I only found listed as obsolete:

PBORCA_CheckOutEntry

PBORCA_CheckInEntry

PBORCA_ListCheckOutEntries



CR:289639
CR Number:   289639
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Jan 2003 Presently Not Targeted For Any Future Release Of This Product
Description
A crash can occur, when setting the background color of a column in the

loose focus event of a datawindow.

The crash occurs if the editstyle of the first column is a radiobutton or

checkbox; not on a normal edit column.

The problem can be platform dependant.



[2002-01-22]

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289662
CR Number:   289662
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 21 Aug 2002 Fixed
Description
Problems passing empty SAFEARRAYs from a COM object to PowerBuilder.



CR:289714
CR Number:   289714
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Feb 2004 Fixed
Description
The return values of several functions have changed from PB 7.0.3 to PB 8.0.2.

For example:

when the DW dataobject property is null (i.e. no dataobject is assigned to the datawindow/datastore), the behaviour is the following :

dw_1.InsertRow(0) // Return -1 in 802, previouslly returned 0

dw_1.AcceptText() // Return -1 in 802, previouslly returned 1

dw_1.Retrieve() // Return -1 in 802, previouslly returned 0

dw_1.GetitemString( 1, 1) // Return null in 802 previouslly the app failed

dw_1.Update( ) // Return -1 in 802, previouslly returned 1

dw_1.SelectRow ( 1, TRUE ) // Return -1 in 802, previouslly returned 1

dw_1.DeleteRow ( 0 ) // Return -1 in 802, previouslly returned 0



Status Update: 02/02/2004

The descriptions of methods have been updated. Can be verified in PB 9.0.1 help files. Also added the following to the Migration Issues section in the PB 9.0.1 release bulletin and the PB8.x readme:



CR:289717
CR Number:   289717
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
DBParm = "PWDialog=1", the password expire window always displays title of "PowerBuilder".



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289724
CR Number:   289724
Product Name:   PB Enterprise
Product Component:   Language - Compiler
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 May 2003 Fixed
Description
We document in the PowerScript Reference Guide how the ampersand character is used to continue a line of code in PowerScript. In the menu painter online help we also document how the ampersand character is used to indicate an accelerator key. For example, entering a text property value of "&Test" displays as "Test" where the first "T" is underscored. This will apply to the text property of controls in general. For example, you could enter a text property for a button of "&Close" and it will display as "Close" with the "C" underscored. We do not document how to have a text control display a literal ampersand, "&". To do this, you need to enter two ampersands. So in the above examples, if you want the menu to literally display as "&Test", enter a text property value of "&&Test", and for the button to literally display "&Close" enter a text property value of "&&Close".



This would also apply to datawindow text objects. So if you retrieve data that includes an ampersand, "mydata&" if you use that data to set the value of a text object in the datawindow, it will display as "mydata_" unless you concatenate on an extra ampersand. You would instead want to set the text control to "mydata&"+"&" which will result in a display of "mydata&".



CR:289733
CR Number:   289733
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 Beta 3 23 Jul 2002 Fixed
Description
View all the options under the projects tab and notice that for web service proxy, it shows a "folder" as the icon.



CR:289735
CR Number:   289735
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 Beta 3 23 Jul 2002 Fixed
Description
Trying to create a web service proxy project, the page

appears blank.



CR:289847
CR Number:   289847
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
PSR data order different than datawindow the psr was generated from.



Workaround:

Specify a sort order sufficient to ensure the order you want in the psr.



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289862
CR Number:   289862
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10227 10 Oct 2002 Fixed
07 Aug 2003 Fixed
Description
7.0.3 EBF Regression: Defined CodeTable values disappear and are lost for a base DataWindow column when another DW is nested in it, and modifications are made to the base DW in the painter, and it's resaved.



Solved by PB Engineering:

Fixed in PB 7.0.3 EBF builds 10227 and greater.



NOTE: The same problem had previously been reported for PB 8.x (see CR 279797) and had already been fixed in PB 8.0.2 EBF builds 9601 and greater, including the 8.0.3 (9704) Maintenance Release, and the PB 9.0 codeline.



CR:289866
CR Number:   289866
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Aug 2002 Fixed
Description
8.0.2 Regression: Datawindow with sort expression crashes PB.



CR:289870
CR Number:   289870
Product Name:   PB Enterprise
Product Component:   DW SaveAs
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
Passing a date column to string defaults to Short Date setting.



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289877
CR Number:   289877
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
PB adds to margin when printing a Windows metafile.



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289900
CR Number:   289900
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.2 20 Aug 2002 Fixed
Description
When line graph datawindow is printed, the data point symbol of the graph are not printed.



CR:289939
CR Number:   289939
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.3 26 Feb 2004 Fixed
8.0.3 26 Feb 2004 Fixed
Description
PowerBuilder 8 Build 9603 uses a new memory manager (versus SmartHeap), and with that build VERY LARGE allocations of memory for datastores are being reported and memory requirements SEEM to be 2x that of the SmartHeap builds.



CR:289952
CR Number:   289952
Product Name:   PB Enterprise
Product Component:   EJB Client
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 Beta 3 02 Sep 2002 Fixed
Description
CreateJavaVM returns -2 on the JavaVM object in the pbEJBClient90.PBD UNLESS I specify the pbejbclient90.JAR in the classpath string argument to CreateJavaVM. If pbejbclient90.jar is in my SYSTEM classpath, it is not sufficient.



CR:289956
CR Number:   289956
Product Name:   PB Enterprise
Product Component:   DW DDDW
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Aug 2002 Fixed
Description
The problem is a gpf with an application error when a

- column which has edit style - DropDownDW

and

- is a secondary datawindow for function ShareData()

and

- a call is made to datawindow GetSQLSelect() on the secondary datawindow.



CR:289958
CR Number:   289958
Product Name:   PB Enterprise
Product Component:   DW SaveAs
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
01 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
When using a nested report the savasascii function does not work. The txt file which gets generated comes with a 1KB size but there is nothing in the file.



NOTE: I suspect this is unsupported but in that case the documentation for SaveAsAscii should be updated to include limitations depending upon datawindow style.



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:289970
CR Number:   289970
Product Name:   PB Enterprise
Product Component:   DB OLE DB
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.3 05 May 2003 Fixed
9.0 29 May 2003 Fixed
25 Apr 2005 Presently Not Targeted For Any Future Release Of This Product
Description
OLE DB not exposing DBHandle( ) with IDBCreateSession needed by MS DTC



CR:289972
CR Number:   289972
Product Name:   PB Enterprise
Product Component:   Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 03 Sep 2002 Fixed
Description
PB 9 Beta 2: Edit Mask Control, select the current text and the insertion location is to right of decimal.



CR:290039
CR Number:   290039
Product Name:   PB Enterprise
Product Component:   DW SaveAs
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 06 Aug 2003 Fixed
Description
Current supporting PowerBuilder version ( 7.x & 8.x), the SaveAs function of Datawindow only supporting old Excel file format.

Enumerated value Numeric value Meaning

---------------- ------------- ---------------------------------------

Excel! 0 Microsoft Excel Version 2 format

Excel5! 14 Microsoft Excel Version 5 format



Customer request to support latest Excel file format. e.g. Office 2000 - Excel 9.0, Office XP - Excel
Workaround Description
 Nil



CR:290046
CR Number:   290046
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.2 14 May 2003 Fixed
Description
PB 8.0.2 regression: Build 9601. An AcceptText() on a dw with no data object returns -1, it used to return a 1.



CR:290047
CR Number:   290047
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 19 Sep 2002 Fixed
3024 14 Aug 2002 Not reproducible with latest version of the product available as of Resolution Date
Description
EditMask ######: Highlighted number overstrike deleting/swapping numbers



CR:290048
CR Number:   290048
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
Retrieving data using a jdbc/db2 connection in easerver results

in the error - [IBM][JDBC Driver] CLI0611E Invalid column name. SQLSTATE=S0022:



Exception

Jul 17 10:28:28 2002: in thread

Jul 17 10:28:28 2002: "Thread-2"

Jul 17 10:28:28 2002:

Jul 17 10:28:28 2002: COM.ibm.db2.jdbc.DB2Exception: [IBM][JDBC Driver] CLI0611E Invalid column name. SQLSTATE=S0022

Jul 17 10:28:28 2002: at COM.ibm.db2.jdbc.app.SQLExceptionGenerator.rsException(SQLExceptionGenerator.java:585)

Jul 17 10:28:28 2002: at COM.ibm.db2.jdbc.app.DB2ResultSet.findColumn2(DB2ResultSet.java, Compiled Code)

Jul 17 10:28:28 2002: at COM.ibm.db2.jdbc.app.DB2ResultSet.findColumn(DB2ResultSet.java:2083)

Jul 17 10:28:28 2002: at com.sybase.powerbuilder.jdbc.PbjdbcRowSet.GetColumnInt(PbjdbcRowSet.java:405)







In the jdbc log,

SQLException: SQLState(42601) vendor code(-104)

COM.ibm.db2.jdbc.DB2Exception: [IBM][CLI Driver][DB2/NT] SQL0104N An unexpected token "END-OF-STATEMENT" was found following "select 1". Expected tokens may include: "<table_expr>". SQLSTATE=42601



at COM.ibm.db2.jdbc.app.SQLExceptionGenerator.throw_SQLException(SQLExceptionGenerator.java, Compiled Code)

at COM.ibm.db2.jdbc.app.SQLExceptionGenerator.throw_SQLException(SQLExceptionGenerator.java:186)

at COM.ibm.db2.jdbc.app.SQLExceptionGenerator.check_return_code(SQLExceptionGenerator.java:419)

at COM.ibm.db2.jdbc.app.DB2Statement.execute2(DB2Statement.java:411)

at COM.ibm.db2.jdbc.app.DB2Statement.executeQuery(DB2Statement.java:333)

at com.sybase.jaguar.jcm.JCMCache.pingConnection(JCMCache.java, Compiled Code)

at com.sybase.jaguar.jcm.JCMCache.getProxyConnection(JCMCache.java, Compiled Code)

at com.sybase.jaguar.jcm.JCMCache.getConnection(JCMCache.java:1588)

at java.lang.reflect.Method.invoke(Native Method)

at com.sybase.powerbuilder.jdbc.PbjdbcSession.CreateJaguarSession(PbjdbcSession.java:444)

SQLException: SQLState(S0022) vendor code(-99999)

COM.ibm.db2.jdbc.DB2Exception: [IBM][JDBC Driver] CLI0611E Invalid column name. SQLSTATE=S0022

at COM.ibm.db2.jdbc.app.SQLExceptionGenerator.rsException(SQLExceptionGenerator.java:585)

at COM.ibm.db2.jdbc.app.DB2ResultSet.findColumn2(DB2ResultSet.java, Compiled Code)

at COM.ibm.db2.jdbc.app.DB2ResultSet.findColumn(DB2ResultSet.java:2083)

at com.sybase.powerbuilder.jdbc.PbjdbcRowSet.GetColumnInt(PbjdbcRowSet.java:405)



May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:290111
CR Number:   290111
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11 Oct 2007 Not reproducible with latest version of the product available as of Resolution Date
Description
8.02 GA & 8.02 ebf build 9601

PB 7.03 build 10197



In library painter, when selecting all the objects in a pbl containing many objects (eg PFC pfcapsrv.pbl) the vertical scrollbar 'jumps' up and down briefly while PB is selecting the objects. Once they are all selected everything returns to normal



CR:290142
CR Number:   290142
Product Name:   PB Enterprise
Product Component:   DW Plugin
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 25 Feb 2004 Fixed
Description
PSR report not displaying in Netscape browser when

either using file/open page/choose file or using the url of http://localhost/ActivitiesLog.psr.
Workaround Description
 View psr report ok using html and the embed tag.



CR:290146
CR Number:   290146
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.2 25 Jul 2002 Duplicate
Description
Regression in 8.0.2 build 9601. Incorrect IDL generated for PB component with overloaded functions, deployment of component fails.



Update:

This turned out to be a dupe of CR 287063. Verified as fixed in PB 8.0.2 EBF Build 9620.



CR:290166
CR Number:   290166
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 May 2003 Presently Not Targeted For Any Future Release Of This Product
Description
DW retrieval arguments losing precision when more than 15 digits.



Workaround:

Send a sting over to the database and then convert it to decimal:

SELECT my_test.id_msg,

my_test.msg_text

FROM my_test

WHERE my_test.id_msg = convert(decimal(16,0),:arg)





May 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:290221
CR Number:   290221
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   NT4
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Oct 2003 Presently Not Targeted For Any Future Release Of This Product
Description
Can't update HtmlDW using IE 4.5 on Macintosh.
Review Status
 October 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".
Workaround Description
 Use IE5 for Macintosh



CR:290238
CR Number:   290238
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Oct 2003 Presently Not Targeted For Any Future Release Of This Product
Description
Datawindow columns disappear when clicking between properties tabs and dw columns.

See repro steps for more details.



This only happens if the Windows Control Panel option "snap to default" for the mouse settings is selected.
Review Status
 October 03

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".
Workaround Description
 Do not use this Windows setting



CR:290239
CR Number:   290239
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 Feb 2004 Workaround
7.0.3 14 Jan 2003 DEFER
Description
Special characters that get returned from a java component as a methods returnvalue (string type) does not display correctly on clients.

This includes characters like the pound and euro sign and affects many customers.

EAServers codeset setting is set to UTF8. (also clients are set to ORBCodeSet='utf8').

For the same component written in PB it works correctly.

Affected are characters that are outside of the 0-127 ascii range.



Update / Solution:

change ORBCodeSet to cp1252 and EAServer codeset to cp1252 , test this issue again using PB804 10501 on Solaris and PB804 10535 on WinNT , pound and euro sign can be displayed properly



CR:290254
CR Number:   290254
Product Name:   PB Enterprise
Product Component:   Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 03 Sep 2002 Fixed
Description
Edit Mask text property not displaying properly in PB 9.0 when

alignment is set to Right! and edit mask has spin set.



Works ok in PB 8.0.2 (build 9601).



CR:290280
CR Number:   290280
Product Name:   PB Enterprise
Product Component:   Migration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   9.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 07 Oct 2002 Fixed
Description
PB 9 Beta2: PB gpfs during migration of 6.5 application to 9.0.



CR:290305
CR Number:   290305
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 14 May 2003 Fixed
Description
8.0.2 Regression: Composite datawindow GPFs on close.



CR:290343
CR Number:   290343
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Jan 2003 Presently Not Targeted For Any Future Release Of This Product
Description
Pressing the SQL button in the DW painter (on a non-graphical SQL statement) is 5-6 times slower than in PB 6.5. Using Oracle 8.1.7 and O84 driver.



January 14, 2003

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:290354
CR Number:   290354
Product Name:   PB Enterprise
Product Component:   EJB Client
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   9.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Aug 2002 Deferred
Description
The properties argument would allow the developer to pass in initialization parameters to the Java VM. Examples include options to control the JavaVM stack size as well as workarounds to other vendor issues, such as a flag required by Oracle's ODBC driver to handle the BLOB datatype.



In beta3 the second argument was changed to a boolean to indicate whether tracing should be turned on or not; however, by substituting this argument for the properties array (in which turning tracing on was also an option), we have eliminated the capability to provide other initialization arguments to the JavaVM.



If possible, this should be corrected before public beta.



CR:290365
CR Number:   290365
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   Microsoft Windows NT
Original Version:   8.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 09 Oct 2002 Fixed
Description
Cust has application that he migrted from PB 7.03 to PB 8.01. In PB 8.01 he opened and ran the application, closed it and when he tried to open it again he GPFs with error title PB80.exe and error is a reference memory error.



The problem seems to be related to the declaration of a global array of structures. However this is not reproducible in a simple test case. Optimizing the PB 7 PBLs before the migration also solved a problem with a different structure declaration.





--------------------------------------华丽的分割线-------------------------------------------------------------------------

Sybase SQL Anywhere数据库恢复工具ReadASADB:

之前就已经研发成功了能够从Sybase SQL Anywhere的DB文件中恢复数据的工具: ReadASADB。
此工具支持ASA v5.0, v6.0, v7.0, v8.0, v9.0, v10.0, v11.0, v12.0, v16.0, v17.0等版本。
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具。
恢复Sybase SQL Anywhere的工具在国内处于领先水平。

Sybase SQL Anywhere数据库恢复工具ReadASADB功能
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具
  1. 适用于所有的SQL Anywhere版本    包括:5.x,6.x,7.x,8.x,9.x,10.x,11.x,12.x,16.x,17.x
  2. 适用于所有的UltraLite版本
  3. 能够恢复出来表结构和数据
  4. 能够恢复自定义数据类型
  5. 能够恢复存储过程等对象的语法
  6. 能够导出到目标数据库
  7. 能够导出到SQL文件并生成导入脚本
  8. 支持多种字符集,包括:cp850、cp936、gb18030、utf8等
  9. 能够恢复未加密或者简单加密类型的数据
  10. 简单易用
  11. 限制:不支持AES加密的数据文件
请参考:研发成功了从Sybase SQL Anywhere的DB文件上恢复数据的工具
            SQL Anywhere数据库非常规恢复工具ReadASADB使用介绍

Sybase SQL Anywhere数据库恢复工具ReadASADB适用场景

各种误操作:

  1. 误截断表(truncate table)
  2. 误删除表(drop table)
  3. 错误的where条件误删数据
  4. 误删除db或log文件
  5. 误删除表中的字段

Sybase SQL Anywhere数据库恢复工具ReadASADB的应用场景:

1.因为物理磁盘故障、操作系统、系统软件方面或者掉电等等原因导致的Sybase SQL Anywhere数据库无法打开的情况;
2.误操作,包括truncate table,drop table,不正确的where条件导致的误删除等;
Sybase SQL Anywhere无法打开时,比较常见的错误是:Assertion failed。
如:
1、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Checkpoint log: invalid bitmap page -- transaction rolled back
2、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Page number on page does not match page requested -- transaction rolled back
3、Internal database error *** ERROR *** Assertion failed:200502 (9.0.2.2451) Checksum failure on page 23 -- transaction rolled back
4、File is shorter than expected
5、Internal database error *** ERROR *** Assertion failed: 201116 Invalid free list index page found while processing checkpoint log -- transaction rolled back
6、*** ERROR *** Assertion failed: 51901 Page for requested record not a table page or record not present on page
7、*** ERROR *** Assertion failed: 201417 (7.0.4.3541) Invalid count or free space offset detected on a table page
8、Internal database error *** ERROR *** Assertion failed: 201425 (8.0.3.5594) Invalid count or free space offset detected on a free list page -- transaction rolled back.
9、Internal database error *** ERROR *** Assertion failed: 100702 (8.0.1.2600) Unable to modify indexes for a row referenced in rollback log -- transaction rolled back


-------------------------------------------------------------------------------------------

Sybase ASE数据库恢复工具READSYBDEVICE:

一个不依赖数据库管理系统、直接从Sybase数据库设备文件上提取数据的业内领先的恢复工具!
能够从损坏的Sybase ASE设备文件(.dat)上提取数据的非常规恢复工具。

Sybase ASE数据库恢复工具READSYBDEVICE的主要功能:

  1. 被勒索病毒加密数据文件及备份文件情况下的恢复;
  2. 系统崩溃只剩下数据文件的情况下的恢复,甚至数据库文件不存在而只有损坏的备份文件情况下的恢复;
  3. 因断电、硬盘坏道等造成数据库文件损坏情况下的恢复;
  4. delete数据恢复、误update数据恢复、误删除表(drop)恢复、误truncate表恢复 等;
  5. 各种Sybase内部系统表损坏、索引错误的修复;
  6. master数据库损坏而无法正常运行情况下的恢复;
  7. Sybase数据库被标记为可疑,不可用等情况的恢复;
  8. Sybase数据库中数据文件内部出现坏块情况下的恢复;
  9. Sybase数据库无数据文件但有日志文件的情况下的恢复;
  10. Sybase数据库只有数据文件无任何日志文件的情况下的恢复;
  11. Sybase数据文件被误删除情况下的碎片提取恢复;
  12. 磁盘阵列上的Sybase数据库被误格式化情况下的数据库恢复;
  13. 数据库sysobjects等系统表损坏无法正常应用情况下的恢复;
  14. Sybase数据库还原数据库出现失败情况下的恢复;
  15. Sybase数据库只剩下损坏的备份文件情况下的恢复。

Sybase ASE数据库恢复工具READSYBDEVICE支持的版本:

Sybase ASE 11.0.x,11.5.x,11.9.x,12.0.x,12.5.x,15.0.x,15.5.x,15.7.x,16.0.x


-------------------------------------------------------------------------------------------

SQL Server数据库恢复工具SQLRescue:

一个不依赖数据库管理系统、直接从SQL Server数据库文件上提取数据的业内领先的恢复工具!
能够从损坏的SQL Server数据库文件(.mdf)上提取数据的非常规恢复工具。

SQL Server数据库恢复工具SQLRescue的主要功能:

  1. 系统崩溃只剩下数据文件的情况下的恢复,即无日志文件或者日志文件损坏情况下的恢复;
  2. 断电导致数据库文件损坏情况下的恢复;
  3. 硬盘坏道造成数据库损坏情况下的恢复;
  4. 数据文件内部存在坏页情况下的恢复;
  5. 企业管理器误删除数据表记录,管理软件误删除数据表记录的恢复;
  6. 并闩锁错误、格式化、误删除后导致软件不能使用的情况;
  7. 无法读取并闩锁页sysindexes失败情况下的修复;
  8. 数据文件被误删除情况下的碎片提取恢复;
  9. 系统表损坏、索引错误、误删除数据库表、删除记录的数据找回;
  10. master数据库损坏而无法正常运行情况下的恢复;
  11. 数据文件无法附加情况下的数据恢复;
  12. 数据库被标记为可疑,质疑,不可用等情况的恢复;
  13. 数据库sysobjects等系统表损坏情况下的恢复;
  14. 数据被误(drop、delete、truncate)删除表数据的恢复,误update后的数据恢复等;
  15. 还原时报一致性错误,错误823等情况下的数据恢复,各种错误提示的数据库文件修复;
  16. 数据库被误格式化等情况下的数据库恢复;
  17. 日志收缩造成数据库损坏情况下的恢复;
  18. 仅剩损坏的备份文件情况下的恢复。

SQL Server数据库恢复工具SQLRescue技术特点:

只要SQL Server数据库的数据文件存在,我们就有办法帮您从数据文件中找回重要数据。
  1. 从数据文件中直接恢复数据
  2. 不能附加时直接恢复数据并生成新的数据库
  3. 系统表损坏的数据库修复
  4. 快速修复SQL 823错误、连接中断错误

SQL Server数据库恢复工具SQLRescue支持的版本:

Microsoft SQL Server 7.0, 2000, 2005, 2008, 2008R2, 2012, 2014, 2016, 2017,2019。
+-------------------------------------华丽的分割线-------------------------------------------------------------------------