提供7*24专业Sybase数据库远程及现场技术支持,Sybase ASE及Sybase SQL Anywhere数据库修复服务,
请联系电话: (微信),QQ: 289965371!
We supply technical support for Sybase ASE and Sybase SQL Anywhere, also have many years of experience in recovering data from damanged Sybase devices.
Please contact us:
Phone:
Wechat: 13811580958
QQ: 289965371 联系我们获取数据库技术支持!
Email: 289965371@qq.com
扫描下方微信,联系我们:
扫描雨翰数据恢复官方微信获取专业数据库恢复服务

 

随着Sybase被完全整合到SAP下,Sybase原来的支持网站被SAP Support Portal取代。
只有购买了SAP服务的用户才能使用账号登录SAP Support Portal进行介质下载、补丁升级、报Incident等。
考虑到Sybase数据库的初学者或者没有购买原厂服务的Sybase客户情况,现提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息。
在SAP Support Portal网站或者google上搜索Targeted CR List for ASE,可以看到针对不同版本的CR(CR表示Change Request)简单描述信息列表。
需要注意的是:Targeted CR List for ASE列出的CR虽然绝大多数是BUG,但有一些是更改需求。
以下提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息!

如有问题,请联系我!

QQ :289965371 联系我们获取数据库技术支持!
Email:
不仅仅包括BUG的详细描述信息,还包括首次报告BUG的平台、数据库版本以及BUG修复历史过程;有些BUG还提供了Workaround来临时解决该BUG带来问题。

 

CR:229731
CR Number:   229731
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
27 Feb 2001 Fixed
Description
The Help pbhlp80.hlp dated 11/28/2000,
indicates the following functions under it's "What's New" section:
- ChooseColor: Customer thinks Help should indicate that the first argument is also passed by reference.
- RemoveDirectory: Customer tested (verified by TSE) that this will fail if the directory that is passed is the current directory. Documentation should indicate that.
- PostURL is not a new function (as the help indicates). It has only been modified to take an additional, optional argument.



CR:229732
CR Number:   229732
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10049 01 Oct 2001 Fixed
Description
Observable memory leak when repeatly execute FindMatchingFunction.

Problem was originally reported on PFC base project. But it was finally be isolated that is caused by the classdefinition object function - FindMatchingFunction.

on a simple example provided can see the leakage by NT Task Manager :

lcd_obj1 = dw_1.classdefinition
for i = 1 to 100
sd = lcd_obj1.findmatchingfunction("Accepttext", ls_args)
sd = lcd_obj1.findmatchingfunction("Accepttext", ls_args)
sd = lcd_obj1.findmatchingfunction("Accepttext", ls_args)
:
:
:
//repeat 12 time here -> overall 1200 call on each button click
next


Capture the follow from Window Task Manager for reference :

No. Mem Usage Diff VM Usage Diff
1 8572K ------ 5772K -----
2 8832K 260K 5900K 128K
3 8952K 120K 6028K 128K
4 9076K 124K 6156K 128K
5 9196K 120K 6284K 128K
6 9320K 124K 6348K 64K
7 9440K 120K 6476K 128K
8 9568K 128K 6604K 128K
Workaround Description
 No Workaround



CR:229738
CR Number:   229738
Product Name:   PB Enterprise
Product Component:   Plug-ins
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 25 Feb 2004 Fixed
25 Feb 2004 Fixed
Description
Using the window plugin and hitting the back or forward button
does not refresh the plugin with Internet Explorer 5.x. Works ok with Netscape.

According to Knowledge Base article, Q199805:
As of Internet Explorer 5, the browser does not refresh pages when the Forward and Back buttons are used.
The behavior of Back and Forward was changed to conform to section 13.13 of the HTTP 1.1 specification, which states the following:

User agents often have history mechanisms, such as "Back" buttons and history lists, which can be used to redisplay an entity retrieved earlier in a session.

From Q234067:
Cache-Control META HTTP-EQUIV tags are ignored and have no effect in
Internet Explorer versions 4 or 5.
<META HTTP-EQUIV="Pragma" CONTENT="no-cache">



CR:229800
CR Number:   229800
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
When you print a composite Dw which contains another composite DW with a header and a footer, then some rows are missing in the printed document.
It seems the footer overlap the last row of each page.



CR:229944
CR Number:   229944
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
When you change the result set of a dw (ie, removing a column), the expressions of the DW are not reevaluated.
Thus, if an expression uses the removed column, PB should prevent from saving the DW because one of the expression used is invalid.



CR:229957
CR Number:   229957
Product Name:   PB Enterprise
Product Component:   MTS Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 Fixed
Description
Different clients calls method lead to serialized execution



CR:229959
CR Number:   229959
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10052 18 Apr 2001 Fixed
Description
If detail band has height set to 0 or 1 and a nested dw is in the group trailer then pb crashes on a print.
Workaround Description
 Workaround :
change the detailband height to more than 2 and it seems to fix the customer's problem.



CR:229965
CR Number:   229965
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
24 Jun 2003 Not a Bug
Description
The new MS SQL Server 7.0 function Replace() cannot be used in embedded sql in PB.
When setting up a cursor for Dynamic SQL Format 3, it results in the errormessage: "Database command has not been prepared successfully.."
WA:
Write a stored procedure which acts as a wrapper for the function call.
Workaround Description
 Write a stored procedure which acts as a wrapper for the function call.



CR:230019
CR Number:   230019
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 Fixed
Description
MTS functionality currently in Powerbuilder should
be backward compatible. When a com object is deploy the COM+ (the
mts version in windows 2000), and then called from a Powerbuilder client,
the which() returns 0. It should return a 2.



CR:230028
CR Number:   230028
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
PB Version and Build:
PB 6.0 GA -> PB 6.5.1 Build 1253 (same behaviour seen in PB 5.0).
Works in PB 7.0 GA -> PB 7.03 and PB 8.0

Comments:
String editmask of upper case /lower case /number etc are ignored by datawindow when data is entered by pasting from clipboard or when retrieved by the datawindow. The same data if entered via edit control has the edit mask applied.
The desired behaviour can be seen in all builds of PB 7 ie the mask is applied to the data pasted from the clipboard or when retrieved from db.



CR:230037
CR Number:   230037
Product Name:   PB Enterprise
Product Component:   DW DDDW
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
This problem is a regression from PB version 6x.
It happens for a datawindow column which has DropDownDatawindow edit style. When this datawindow is placed on a composite datawindow (thus becomes nested report object), PB will gpf when performing the composite datawindow RETRIEVE operation.
The workaround is to use a DropDownListbox or a column edit style of "Edit".
Workaround Description
 Verified that using DropDownListbox or a column edit style of "Edit" does not cause the application to gpf.



CR:230044
CR Number:   230044
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Apr 2001 Not a Bug
Description
When a copy of the pbvm70.dll is in the winnt\system32 directory
and you call up Powerbuilder's development environment, pb will gpf
when you right mouse click on an object in the library painter.

The pbvm's are the same version. If you start pb70.exe from the Powerbuilder
directory and not from the shared directory than no problem.

The following is the crash handler output:
Exception code: C0000005 ACCESS_VIOLATION
File Name: ,wp伫w8
File Version:
Fault address=02BB001F Section:Offset=00:0012F494

Registers:
EAX:01220124
EBX:BC000002
ECX:0122A8D8
EDX:01112218
ESI:01111E28
EDI:10A61610
CS:EIP:001B:02BB001F
SS:ESP:0023:0012F954 EBP:00000000
DS:0023 ES:0023 FS:0038 GS:0000
Flags:00010A82

Call stack:
Address Frame Param0 Param1 Param2 Param3 Function Name

OS version:
Windows NT 4.0, Build Number: 1381, Service Pack 6

Memory Status:
Total physical memory: 196024K
Available physical memory: 72440K
Total virtual memory usage: 149572K / 377164K
PowerBuilder virtual memory usage: 76516K / 2097024K

Loaded Modules:
E:\pb70\PowerBuilder 7.0\Pb70.exe 7.0.2.8037
C:\WINNT\System32\ntdll.dll 4.00
e:\pb70\Shared\PowerBuilder\PBSYS70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBCMP70.dll 7.0.3.10039
C:\WINNT\System32\PBVM70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\libjcc.dll
C:\WINNT\system32\WSOCK32.dll 4.00
C:\WINNT\system32\KERNEL32.dll 4.00
C:\WINNT\system32\WS2_32.dll 4.00
C:\WINNT\system32\MSVCRT.dll 6.10.8293.0
C:\WINNT\system32\USER32.dll 4.00
C:\WINNT\system32\GDI32.dll 4.00
C:\WINNT\system32\ADVAPI32.dll 4.00
C:\WINNT\system32\RPCRT4.dll 4.00
C:\WINNT\system32\WS2HELP.dll 4.00
C:\WINNT\system32\comdlg32.dll 4.00
C:\WINNT\system32\SHELL32.dll 4.00
C:\WINNT\system32\COMCTL32.dll 5.81
C:\WINNT\System32\WINSPOOL.DRV 4.00
C:\WINNT\system32\ole32.dll 4.00
C:\WINNT\System32\OLEPRO32.DLL 5.0.4277
C:\WINNT\system32\OLEAUT32.dll 2.40.4277
C:\WINNT\system32\VERSION.dll 4.00
C:\WINNT\system32\LZ32.dll 4.00
C:\WINNT\System32\oledlg.dll 1.0
e:\pb70\Shared\PowerBuilder\PBDWE70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBDTS70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBDWP70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBSQL70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBLIB70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBDEV70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBORC70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBAPL70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBUDO70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBSCR70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBWED70.dll 7.0.3.10039
e:\pb70\Shared\PowerBuilder\PBDPP70.dll 7.0.3.10039
C:\WINNT\system32\MSIDLE.DLL 5.50.4522.1800
C:\WINNT\System32\mpr.dll 4.00
C:\WINNT\System32\ntlanman.dll 4.00
C:\WINNT\System32\NETUI0.dll 4.00
C:\WINNT\System32\NETUI1.dll 4.00
C:\WINNT\system32\NETAPI32.dll 4.00
C:\WINNT\system32\NETRAP.dll 4.00
C:\WINNT\system32\SAMLIB.dll 4.00
C:\WINNT\System32\rpcltc1.dll 4.00
C:\WINNT\System32\ntshrui.dll 4.00
C:\WINNT\System32\LinkInfo.dll 4.00
C:\WINNT\System32\IMAGEHLP.DLL 4.00
C:\WINNT\System32\psapi.dll 4.00
Workaround Description
 If the pblib70.dll is moved to the winnt\system32 directory
where the pbvm70.dll is located than no problem.

If you start pb exe from Powerbuilder 7.0 directory and not
from the shared directory it works too.



CR:230073
CR Number:   230073
Product Name:   PB Enterprise
Product Component:   DB Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Jun 2001 Fixed
Description
GPF trying to display Foreign Key's properties when the Primary Key Table Name referenced in the relationship contains an upper case.



CR:230074
CR Number:   230074
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10056 22 Mar 2001 Fixed
Description
PB 6.5.1 and higher :
ScrollToRow function triggers a gpf when the target row has its height egals to 0 or 1.



CR:230084
CR Number:   230084
Product Name:   PB Enterprise
Product Component:   DB Profile
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 3.1 3119 28 Mar 2001 Fixed
8.0 Beta 3.1 3118 18 Jan 2001 Fixed
8.0 Beta 3.1 3120 28 Mar 2001 Fixed
8.0 Beta 3.1 3120 28 Mar 2001 Fixed
Description
PB8 Beta2: Outer Join Syntax dropdown in DB profile doesn't have default. There are three options but it defaults to blank. It should default to one of the 3 selections.



CR:230125
CR Number:   230125
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
OS: Win32
PB Version and Build: Broken between PB 7 build 8046 (C3 release) and post C3 ebf build 9010.
Also broken in PB 8, PB 6.x OK.
Comments:
In an inherited object (tested with user objects and windows) with a user event. If this user event references AncestorReturnValue in the script, the script painter will give a compiler error for AncestorReturnValue if you had a previous compile error in this same script for any other reason and tried to save (CTRL + S) rather than simply compile (CTRL + L) that error.
Could be a regression introduced with CR 221758 (fixed around that time - related problem)
Simple workaround exists
Workaround Description
 Comment out reference to AncestorReturnValue
-> CTRL + S
-> Uncomment
-> CTRL + S



CR:230129
CR Number:   230129
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
MDI application. Using the 'tab' key causes different behavior than if use the 'enter' key when exiting a datawindow on one sheet and opening another sheet with a datawindow. The cursor disappears from the second datawindow after using the tab key, on the SECOND time going from window 1 (w_selection in the example) to window 2 (w_data_entry in the example). The first time is OK and the cursor is visible. Clicking in column and the cursor returns. Using the Enter key instead of the Tab key the cursor is always present.



CR:230134
CR Number:   230134
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
In PB 7.0.3 if you set the FontCharSet to something other than "ansi!" for a SLE and then either de-select it or save the window it reverts back to "ansi!". If you save the window and export it the property is either missing entirely. When "defaultcharset!" was selected the entry was missing in the exported syntax and when "thaicharset!" was selected it was in the exported syntax but did not appear on the font tab.

This property is greyed out in PB 8.0 as reported in CR 228888 so cannot test.



CR:230137
CR Number:   230137
Product Name:   PB Enterprise
Product Component:   Debugger
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
08 Mar 2001 Presently Not Targeted For Any Future Release Of This Product
Description
Debugging through some code. Reached a breakpoint. Switched variable
pane from Local to Instance. Reviewed some instance variables. Switched variable
pane from Instance to Local - PB Crashed.



CR:230138
CR Number:   230138
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Customer requests to allow extra formats for importing ascii text files: in particular using different delimiters. The tab-delimited format is very limited. There should be an option to specify a different delimiter, such as a comma.

In database painter, open a table, edit data, then go to Rows>Import.
The only formats offered are .dbf and .txt, which must be a tab-separated file.
Customer asks that other formats be made available, such as a text format based on comma separated values....



CR:230139
CR Number:   230139
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
When I select multiple columns and / or headers in a gridstyle DW, the option for sizing all objects the same width is not available. You can select the option to make all the same height or to make the same width & height. Please add the option to make all the same width.



CR:230143
CR Number:   230143
Product Name:   PB Enterprise
Product Component:   Structure - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Customer would like to see implemented the following function:
SizeOf (structure)
or (more OO):
structure.sizeof()
(Though structures don't have methods at the moment)

ref to CR# 151102 this was reported as an enhancement request with PB 4.0 but has not been implemented.



CR:230145
CR Number:   230145
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request - In IDE add capability to float a group of tabbed panes, versus just one at a time



CR:230146
CR Number:   230146
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request: When you have multiple object painters open in IDE you have to go to Window menu to switch between. Customer would like to have tabs (as they are at the pane level) to work for the individual painter windows as well.



CR:230154
CR Number:   230154
Product Name:   PB Enterprise
Product Component:   DW Synchronization
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
03 Oct 2001 Fixed
Description
Regression: GetFullState/SetFullState not getting dddw data anymore, after around build 9023 or 9028.



CR:230176
CR Number:   230176
Product Name:   PB Enterprise
Product Component:   Install
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Jan 2001 Fixed
Description
First splash dialog refers to product in two places as "Sybase Common PowerBuilder 8.0" which seems a bit awkward... please rephrase.



CR:230183
CR Number:   230183
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 Mar 2001 Duplicate
Description
This problem is a regression and occurs in the development environment object painter for inheritance.
e.g. Window painter, User Object painter, Menu painter.
For example, in all the respective object painters above, in "Script pane" there are 3 dropdownlistboxes :-
- Object/Functions/Declares
- Script/Declare Type
- Ancestor/Descendant

The 'Extend ancestor script' setting is disabled if ddlb 'Objects,Functions or Declares' is toggled.
This failure happens for ALL objects which ARE inherited and EXTEND ancestor functions:-
-Menu
-Window
-User object

This failure happens when toggling object scripts using the 'Objects,Functions or Declares' ddlb.
If the PB object is doubleclicked/ chosen/ toggled from either of the places below, the problem described
does not occur:
- Control list pane/ tab
OR
- Layout pane/ tab
Workaround Description
 Toggle PB object from CONTROL list pane/ tab OR LAYOUT pane/ tab INSTEAD OF using the 'Objects,Functions or Declares' ddlb



CR:230187
CR Number:   230187
Product Name:   PB Enterprise
Product Component:   UO Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Sep 2001 Fixed
25 Feb 2004 Fixed
Description
Descendent uo inherited from an nvo declared as global var and has autoinstantiate on then immediately after a full rebuild opening the desc uo causes a gpf.



CR:230244
CR Number:   230244
Product Name:   PB Enterprise
Product Component:   Project Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request : Suggest adding tabs to the application project painter dialog: General (contain exe, resource file, compiler options), Libraries (list of PBLs/PBDs), Version (version information). This will enable easier use of this painter.



CR:230245
CR Number:   230245
Product Name:   PB Enterprise
Product Component:   Install
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Mar 2001 Fixed
Description
Customer information screen has direction to "Please enter your name and the name of the company for whom you work." Companies are 'whats' not 'whos'... change the word 'whom' to 'which'. Make grammatically correct.



CR:230246
CR Number:   230246
Product Name:   PB Enterprise
Product Component:   Install
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 Apr 2001 Not a Bug
Description
The Select Components dialog has a Disk Space button, when pressed (on a machine with 11 shared drives) the dialog took over a minute to appear and during that time the cursor remained an arrow giving the impression the installation had hung

Suspecting the delay is due to number of remote drives being searched, if this can't be helped at least the cursor should change to hourglass



CR:230251
CR Number:   230251
Product Name:   PB Enterprise
Product Component:   DB Informix
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Select stmts getting generated for Outer Joins is different in Graphic and Syntax mode.
Workaround Description
 save the dw in syntax mode.



CR:230269
CR Number:   230269
Product Name:   PB Enterprise
Product Component:   Install
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 Mar 2004 Presently Not Targeted For Any Future Release Of This Product
Description
ASA 7 install incurs an error 75% through installation when setting up asademo.db. A message box is displayed with error and installation halts until this box is cleared. At 75% completed while 'building the asademodb' get an error box titled Interactive SQL "Error at line 1: Database cannot be started - No such file or directory"... installation halts pending clearing of this box

Second time I simply changed the drive from C: to D: and during the install received a different error as follows.

SQL Anywhere 7 Install

An error occured during the move data process -2147024909
Component: Script Component
File Group: dbtool_scripts
File:

When I reinstalled taking all the defaults it installed just fine.



CR:230271
CR Number:   230271
Product Name:   PB Enterprise
Product Component:   Debugger
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:
Add a view to see datawindow/datastore buffers in debugger without requriring getitems be sprinkled within code



CR:230318
CR Number:   230318
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 May 2001 Presently Not Targeted For Any Future Release Of This Product
Description
If you have Snap-to option set for mouse pointer, dw columns move on click
Workaround Description
 Workaround : Uncheck the Snap - To Property for a mouse pointer.



CR:230324
CR Number:   230324
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 Apr 2001 Fixed
Description
PB 8 build 3105 :
this cr is related to cr 226289
1) In clip window delete all the characters in the name.
2) Open the file editor
3) Notice you get a error message box saying "You must type filename", this should infact say something like "You must type clip name".
4) The error messagebox comes up 4 times, not just once.



CR:230334
CR Number:   230334
Product Name:   PB Enterprise
Product Component:   DB OLE DB
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 Jan 2001 Fixed
Description
Description of Problem: PB crashes if you enter value into Retrieve Blocking Factor on Transaction tab of OLE-DB database profile



CR:230336
CR Number:   230336
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jan 2001 Fixed
Description
Description of Problem: Print option labels from File menu do not follow standard windows paradigm when dealing with ellipses



CR:230346
CR Number:   230346
Product Name:   PB Enterprise
Product Component:   Internet Class Library
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Feb 2001 Not a Bug
Description
From Powerbuilder, a posturl function is calling a url
with arguments. The powerdynamo web page
then prints the arguments on the web page.

The web page is using dynascript. Using the geturl(), the arguments
show up on the web page. With posturl, it appears as if the dynascript
isn't being processed. The arguments don't appear on the web page
after being called.

The stm page being called from Powerbuilder is as follows:
<HTML>
<TITLE>PostURL Test</TITLE>
<BODY>
<H1>PostURL Test</H1>
<!--SCRIPT
var szUser;
var szPwd;

if ( exists( document.value.user ) )
{
szUser = document.value.user;
document.writeln( "User: " + szUser + "
" );
}
if ( exists( document.value.pwd ) )
{
szPwd = document.value.pwd;
document.writeln( "Password: " + szPwd + "
" );
}
-->
<form id="myForm" action="posturl.stm" method="POST">
<table border="0" width="150">
<tr>
<td>User:</td>
<td><input name="user" type="text" size="25"></td>

</tr>
<tr>
<td>Password:</td>
<td><input name="pwd" type="text" size="25"></td>
</tr>
<tr>
<td colspan="2" align="center"><input type="Submit" value="Submit"></td>
</tr>
</table>
</form>
</BODY>
</HTML>



CR:230386
CR Number:   230386
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Jun 2001 Duplicate
Description
HTMLDW: Generating grid dw adds an extra column in between this of the select (<TD></TD>).

Workaround :
Add code in the generate()
long position1
string ls_TD="<TD></TD>"
DO
position1 = pos(ls_result, ls_TD)
if position1 > 0 then
ls_result = Replace ( ls_result, position1, 9, "")
end if
LOOP UNTIL (position1 = 0)
Workaround Description
 code in generate() function of dw component
long position1
string ls_TD="<TD></TD>"
DO
position1 = pos(ls_result, ls_TD)
if position1 > 0 then
ls_result = Replace ( ls_result, position1, 9, "")
end if
LOOP UNTIL (position1 = 0)



CR:230388
CR Number:   230388
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
HTMLDW:grid dw with background color <> than windows cuase the dw to resizes to browser size. Caused by the width=100% in generated HTML.
code in generate() function of dw component
long position2
String ls_width = "; width:100%"
DO
position2 = pos(ls_result, ls_width)
if position2 > 0 then
ls_result = Replace ( ls_result, position2, 12, "")
end if
LOOP UNTIL (position2 = 0)
Workaround Description
 code in generate() function of dw component
long position2
String ls_width = "; width:100%"
DO
position2 = pos(ls_result, ls_width)
if position2 > 0 then
ls_result = Replace ( ls_result, position2, 12, "")
end if
LOOP UNTIL (position2 = 0)



CR:230406
CR Number:   230406
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jan 2001 Fixed
Description
The original problem with cr224314 was that when
saving scripts with informational/warning messages, you were prompted to
"Ignore compilation warnings and lose changes". If you say yes, the
changes took.

The behavior now after the fix was made is, the warning message appears
"Ignore compliation warnings and lose changes". If you say yes, the
changes don't take effect. (Which is what you want it to do.). If you say no,
the compilation warning now becomes a syntax error.



CR:230407
CR Number:   230407
Product Name:   PB Enterprise
Product Component:   Workspace and Targets
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Apr 2001 Fixed
Description
Description of Problem: Cannot complete source code controlled web target wizard - gets to final screen and Finish seems to do nothing (Back and Cancel do nothing either!). If you exit using the X at the top right of the window you get the message: "Error calling external function pf_getsourcecontrolledtarget at line 4 in function f_getsourcecontrolledtarget of object common_routines_win32"



CR:230408
CR Number:   230408
Product Name:   PB Enterprise
Product Component:   AutoScript
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
12 Mar 2001 Fixed
Description
PB8 Beta3: Autoscript popup window cannot be scrolled far enough to see entire function prototype for some functions.



CR:230411
CR Number:   230411
Product Name:   PB Enterprise
Product Component:   AutoScript
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB8 Beta3: Enhance autoscript to show return values for functions



CR:230413
CR Number:   230413
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 RC 5009 03 Apr 2001 Fixed
Description
PB8 Beta3: MDI application flashes when opening or closing a sheet.



CR:230434
CR Number:   230434
Product Name:   PB Enterprise
Product Component:   DB Other
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
27 Feb 2001 Fixed
Description
The identity column value with a data type of counter is not getting assigned to the datawindow in Microsoft Access 97 Database. It does get inserted into the db. You must do a retrieve to see the identity column.
Workaround Description
 Do a second retrieve after inserting the record.



CR:230438
CR Number:   230438
Product Name:   PB Enterprise
Product Component:   DB Informix
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10039 18 Apr 2001 Fixed
Description
Informix error SQLerror -1226 Decimal or money value exceeds maximum precision
when using a cursor fetching a decimal value 0 from a column with zero precision
Workarounds:
retrieve into datastore
use double instead of decimal datatype
Workaround Description
 retrieve into datastore
use double instead of decimal datatype



CR:230491
CR Number:   230491
Product Name:   PB Enterprise
Product Component:   DataBase Administrator
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
27 Mar 2001 Fixed
Description
Selecting the synonyms in the db admin painter, the actual
synonym name doesn't display, but the tablename. For example, when logged in as user system
and enabling the 'show system synonyms', I see sys.sm_$version, which is the
tablename for the synonym sm$version. select * from all_synonyms gives a list of synonyms.
This worked in PB 7.02 build 8003



CR:230498
CR Number:   230498
Product Name:   PB Enterprise
Product Component:   Function Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Sep 2001 Fixed
Description
Attempt to overload a global function by a customer resulted in a GPF using 7.0.3 build 10009, and a Bad Mem Pointer error using 7.0.3 build 10039. Although this is not allowed, the product should handle the error with and error message instead.



CR:230502
CR Number:   230502
Product Name:   PB Enterprise
Product Component:   Installation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Feb 2001 Fixed
Description
Minor Beta3 setup issue. I get a set of message boxes telling me that various DLLs registered correctly. All I want to know about is the ones that failed. Hitting me with a half dozen message boxes telling me things are fine is user-unfriendly.



CR:230541
CR Number:   230541
Product Name:   PB Enterprise
Product Component:   DB Profile
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Mar 2004 Presently Not Targeted For Any Future Release Of This Product
Description
Database profiles are stored in the registry and the password is

encrypted. When connecting thru the development environment,

pb will decrypt the password.



When running a pb application at runtime, there is no mechanism

to decrypt the password.



Customer would like to have a option in the db profile so that you

set if you want a application at runtime to automatically decrpyt

the db password. If the option is not set, than pb will not decrypt

and the user will get a db error.



CR:230549
CR Number:   230549
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jan 2001 Fixed
Description
GUI shows Extend Ancestor Script checked (but disabled) in function painter



CR:230552
CR Number:   230552
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Nov 2011 Deferred
Description
Enhancement request for grid dw style to support multi-row and multi-column spans - like the capability you get with HTML ROWSPAN and COLSPAN tags.



CR:230598
CR Number:   230598
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
SYJ connection against ASE
======================
Connection/Disconnection with SYJ driver (PBSYJ70.DLL) may result in a DB Lock when a REFRESH is perform on the component deployed against Jaguar.
It does not occur using SYC or ODBC connection



CR:230602
CR Number:   230602
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
ENHANCEMENT - Add a browse button for the initialization path on
the system options display.



CR:230611
CR Number:   230611
Product Name:   PB Enterprise
Product Component:   DW DDDW
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
07 Mar 2001 Fixed
05 Mar 2001 Fixed
13 Mar 2001 Fixed
Description
PB8 Beta3: Autoretrieve setting on dddw edit style should be true by default.



CR:230622
CR Number:   230622
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Mar 2001 Fixed
Description
Dynamically setting the Required property for an editmask , causes display of a large negative number when you set focus on the number column that has the editmask.



CR:230623
CR Number:   230623
Product Name:   PB Enterprise
Product Component:   WT - Import
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Feb 2001 Fixed
Description
Import an asp script into a web target and
it does not show up in the html editor. All that shows up is
<META HTTP-EQUIV=PowerSiteData...>.

You cannot edit this asp script. If you do and then save it, close
out of pb and open pb again, the changes did not save.



CR:230624
CR Number:   230624
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Feb 2001 Fixed
Description
PB 8.0 3050, 3105
Description of Problem: The GetFolder function's 2nd argument is a directory that will be initially displayed in a standard Windows browse folder dialog. Upon selecting a new directory, that argument will then contain the selected path. If you cancel the dialog, the GetFolder function returns 0 to indicate the cancellation, BUT the directory argument is also cleared. If a new directory is not selected, the argument should be left alone.

This is not a big deal to work around, but I don't think it's correct behavior. If we can't address this with a fix, can we document the behavior?



CR:230638
CR Number:   230638
Product Name:   PB Enterprise
Product Component:   Target Wizards
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Apr 2004 Fixed
Description
If regional settings are Norwegian (either of two flavors) or Russian, Dynamo Web Target wizard claims PowerDynamo is not installed. Some other foreign regional settings seem to work without a problem such as
German and Greek.

When trying to create thte New Dynamo Website Target the Next button will be greyed out and you will notice that there is a message at the bottom of the wizard window that states : "Dynamo is not installed on this system. Install PowerDynamo and try again." If you change the regional setting to the United States default you will see that this works fine.



CR:230642
CR Number:   230642
Product Name:   PB Enterprise
Product Component:   Workspace and Targets
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement request to be allow a Full or Incremental rebuild from System Tree View while other painters are open.



CR:230649
CR Number:   230649
Product Name:   PB Enterprise
Product Component:   UO Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Sep 2001 Fixed
Description
You are allowed to open multiple user objects in a hierarchy and should not be (PB 6 doesn't allow this).

Only occurs on objects that are not direct ancestor/descendants but rather have another level between them; does not occur in PB 6.



CR:230713
CR Number:   230713
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
New Feature Request: Provide a source code control option to check in a object and immediatly check it back out (versus requiring two separate actions check-in then check-out).



CR:230729
CR Number:   230729
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
24 Jan 2001 Fixed
Description
Prompt on exit not working when a web target in a workspace
was the last one 'touched' or a empty workspace. No prompt is issued.



CR:230747
CR Number:   230747
Product Name:   PB Enterprise
Product Component:   AutoScript
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 4 09 Mar 2001 Fixed
Description
Autoscript window can leave it's frame behind (no contents). Frame is still in the foreground even when another application such as Lotus Notes is brought up. Originally reported as also sometimes resulting in a crash but with beta 3 I could not reproduce the crash.

Pressing the Escape key or clicking in the script area should make the frame close.



CR:230757
CR Number:   230757
Product Name:   PB Enterprise
Product Component:   Debugger
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
This is probably going to turn out to be an enhancement request but submitting it as a bug initially.

If using just-in-time debugging, execution stops when an exception or runtime error is encountered, even if that error is caught and processed via a TRY-CATCH block

This may be pretty tough to do, since you really don't know if the exception is being caught until you get to the CATCH block, and since we're interpreting code here, we'd have to look ahead to determine this.



CR:230759
CR Number:   230759
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
A dw with a dddw populates with the data column
of a dddw instead of the display column using getfullstate/setfullstate.
Problem happens if the column is in the header or the detail band of a
datawindow.

In pb 7.0.3 versions 8046 and 9028, the problem was restricted to the header
band of the dw. The data column showed in the header and the display
column showed in the detailed. The problem has regressed where the
data column shows up in the detail and the header band even though the
property is set to show the display column.



CR:230762
CR Number:   230762
Product Name:   PB Enterprise
Product Component:   Install
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
4020 07 Mar 2001 Fixed
Description
This was first reported as CR 223556. There is a note in the resolution that if this is still a problem in Beta 3 then to open bugs on specific instances.

When installing PB8, both Custom and Compact tested, about 80% through, it starts installing 'Powersite' stuff and the InstallShield dialog says 'Copying Powersite files..." Others may have flashed quickly but these were noted.

Installing PowerSite Program Files
PowerSite Self-Registering DLLS
PowerSite Self Registering Active Xs and
PowerSite Help files.



CR:230812
CR Number:   230812
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10062 26 Mar 2001 Fixed
Description
PowerBuilder 6,7:
Clicking a button within a dataWindow fires a GPF if the datawindow has :
1) a computed field which call a global function
AND
2) some script in its CLICKED event



CR:230834
CR Number:   230834
Product Name:   PB Enterprise
Product Component:   DB OLE DB
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10049 22 Feb 2001 Fixed
Description
Regression: MSS 7.0 OLEDB connection not dropped on disconnect starting around 7.0.3 build 10037.



CR:230835
CR Number:   230835
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
07 Jun 2006 Fixed
Description
Return 2 in sqlPreview event of a datawindow does not prevent the update from being executed when the update is based on a Stored procedure
Workaround Description
 Use :

SQLpreview event : Return 1
DBError event : Return 1 (to prevent the error message from being displayed)



CR:230893
CR Number:   230893
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Solaris 2.6
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 Fixed
Description
If a dw object name is assigned using upper or mixed case the deployed component (Jaguar on Solaris) will not assign the dw object. when
running pb client. This works when component is deployed to Jaguar on NT.



CR:231014
CR Number:   231014
Product Name:   PB Enterprise
Product Component:   Menu Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 4 4010 01 Mar 2001 Fixed
Description
When in the menu painter and you select view/layout/default,
Powerbuilder will disappear.



CR:231056
CR Number:   231056
Product Name:   PB Enterprise
Product Component:   Browser
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Description of Problem: Can not see variables and function create in a UO in the OLE Browser using the OLE Automation project wizard.
1) Create a non-visual user object.
2) Create some functions and variables in the user object.
3) Create a new automation server wizard project using the NVO just created. (make sure to generate reg and tlb files for this project)
4) Build the automation server wizard project (the reg and tlb files should be created)
5) Import the reg file into the registry.
6) Open the OLE object browser in PB, and look for the NVO, expand the NVO, no functions or variables are listed.
7) If you look at the Powerbuilder Automation object in the OLE object browser, there are functions and variables listed.



CR:231107
CR Number:   231107
Product Name:   PB Enterprise
Product Component:   Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
PB7 Umlauted characters are ignored in EditMask Controls on GERMAN W95 and NT4
MaskDataType: stringmask; Mask: alphnumeric (aaaaaaaaaaaaaaa)



CR:231151
CR Number:   231151
Product Name:   PB Enterprise
Product Component:   WT - System Tree
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Oct 2007 Fixed
Description
Enhancement request to provide context menu option in system tree to set current target (now, the only way is via Select and Run/Debug), additionally provide some visual of what the current target is in system tree



CR:231183
CR Number:   231183
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Feb 2001 Not a Bug
Description
The finditem returns the incorrect handle number
when used in a treeview.

When you click on the treeview, the root item returns the correct handle. You
then click on the child and it returns the incorrect handle number the first
time you click on it. You click again and it returns the correct handle.

long ll_handle
ll_handle = tv_1.FindItem(CurrentTreeItem!, 0)



CR:231187
CR Number:   231187
Product Name:   PB Enterprise
Product Component:   DataBase Administrator
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Mar 2001 Presently Not Targeted For Any Future Release Of This Product
Description
Specifying TableName or TableOwner in PBDIR TableCriteria results in no table being returned. This also fails in PB 7.03.



CR:231191
CR Number:   231191
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Mar 2001 Not a Bug
Description
PB8 Beta3: The Save Icon in the datawindow painter remains enabled after a save, even when no changes have been made. In other painters, the icon is disabled when no changes have been made after a Save.



CR:231202
CR Number:   231202
Product Name:   PB Enterprise
Product Component:   DB Other
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
The identity column value with a data type of counter is not getting assigned to the datawindow in Microsoft Access 97 Database. It does get inserted into the db. You must do a retrieve to see the identity column.



CR:231341
CR Number:   231341
Product Name:   PB Enterprise
Product Component:   Install
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Jan 2001 Duplicate
Description
PB8 Beta 3 install, resrv registers some dlls. The boxes reporting that the registration succeeded remain open and have to be manually closed. It would be better if these messages were not displayed.



CR:231346
CR Number:   231346
Product Name:   PB Enterprise
Product Component:   WT - System Tree
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 4 06 Feb 2001 Fixed
Description
PB8 Beta3: allowed to Edit Source and be in object painter at same time.



CR:231347
CR Number:   231347
Product Name:   PB Enterprise
Product Component:   Printing
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.1 1274 31 Oct 2002 Fixed
Description
This is probably a duplicate of CR 219374 but as that was a different HP printer a new CR was opened.

Customer has a PB 6.5.1 application that when run on WIN 95 connected to a HP950C local printer causes a gpf in in a print driver dll( HPF9XDRO.DRV). The gpf occurs when there is a picture object on the datawindow and the bitmap has been reduced in size. Size of actual bitmap seems to be an issue here.

Problem does not occur on NT 4.0 or on WIN95 with PB 7.0.3.



CR:231362
CR Number:   231362
Product Name:   PB Enterprise
Product Component:   WT - Build
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Apr 2005 Presently Not Targeted For Any Future Release Of This Product
Description
PB error during a rebuild of an application that incorrectly has script to CREATE an autoinstantiated NVO. The error is detected in rebuild, but the PBL is then rendered useless: an attempt to run the app will crash PB; an attempt to reopen the PBL will fail with an infinite loop of migration requests.

To duplicate:

1. Run the provided application within PowerBuilder. The NVO uo_hello is currently NOT autoinstantiated and the code in the app open event simple CREATEs an instance and calls a method. You should see a Hello, World message box when running it.

2. Open uo_hello and check autoinstantiate on the property sheet.

3. Do a full rebuild - you should get an error indicating Autoinstantiated class illegal for CREATE (this is correct)

4. Now try to run the application, it crashes PB

5. Reopen PowerBuilder and now try to open the workspace/target - you get presented the migration dialog. Migration, however, will fail beacuse of the error in step 3, and you end up in an infinite loop of migration requests.

6. The only way I've been able to 'fix' it is to add the PBL to another existing target, export the uo, delete the autoinstantiate tag, reimport and remigrate the original target. Doing this 'wrong' though seems to cause PB to crash quite a bit.

Alternatively, don't run the application in PB as in step 4, but just close the workspace and try to reopen it, you'll still see the infinite loop of migration requests.



04/25/2005:

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".
Workaround Description
 Add the PBL to another existing target, export the uo, delete the autoinstantiate tag, reimport and remigrate the original target.



CR:231435
CR Number:   231435
Product Name:   PB Enterprise
Product Component:   Configure ODBC
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
06 Jun 2001 Third Party Problem
Description
Cannot create a dsn using PB MERANT OEM 3.60 32-bit XML driver either in odbc administrator or PB.
In ODBCAD32 create a dsn based on the above driver and you will get the following error :
'Driver's ConfigDSN, ConfigDriver, or ConfigTranslator failed' and 'Failed to Initialize Setup Dialog' errors when trying to create an Integrator system ODBC data source.



CR:231449
CR Number:   231449
Product Name:   PB Enterprise
Product Component:   DW Graph
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 3.1 4014 13 Mar 2001 Fixed
Description
PB8 beta: Category axis text Format alters graph title instead.
This also happens in 7.0.3.



CR:231477
CR Number:   231477
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
06 Apr 2001 Not a Bug
Description
PB8 Beta3: Library painter treeview and listview are inconsistent when using the System Options 'reopen workspace on startup' and 'reload painters when opening workspace'. If you were last in the library painter, and had both the treeview and the listview showing the most recent object (View...Most Recent Object), when you restart PowerBuilder, the library Treeview will still display the most recent object. The ListView will not.

Per Development: the library painter is not supposed to display the most recent object on startup.
What the library painter will do is have the same root at startup for the tree view.



CR:231479
CR Number:   231479
Product Name:   PB Enterprise
Product Component:   Project Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Sep 2001 Fixed
Description
Powerbuilder will crash when in the library painter
and you select deploy workspace.

The following is the crash handler results:
Exception code: C0000005 ACCESS_VIOLATION
File Name: E:\pb80\Shared\PowerBuilder\PBAPL80.dll
File Version: 8.0.00.3113
Fault address=1080B5D8 Section:Offset=01:0000A5D8

Registers:
EAX:00000001
EBX:01204F6C
ECX:01620034
EDX:00000000
ESI:01620034
EDI:00000000
CS:EIP:001B:1080B5D8
SS:ESP:0023:0012DE8C EBP:01204F54
DS:0023 ES:0023 FS:0038 GS:0000
Flags:00010296

Call stack:
Address Frame Param0 Param1 Param2 Param3 Function Name
1080B5D8 01204F54 00000000 01200034 00000000 00000000 0001:0000A5D8 E:\pb80\Shared\PowerBuilder\PBAPL80.dll
00000000 01204F6C 00000000 01200034 00000000 00000000 0000:00000000
00000000 01204F84 00000000 01200034 00000000 00000000 0000:00000000

OS version:
Windows NT 4.0, Build Number: 1381, Service Pack 6

Memory Status:
Total physical memory: 196024K
Available physical memory: 66472K
Total virtual memory usage: 158284K / 377140K
PowerBuilder virtual memory usage: 179520K / 2097024K

Loaded Modules:
E:\pb80\PowerBuilder 8.0\pb80.exe 8.0.00.3050
C:\WINNT\System32\ntdll.dll 4.00
E:\pb80\Shared\PowerBuilder\PBSYS80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBCMP80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBVM80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\libjcc.dll
C:\WINNT\system32\WSOCK32.dll 4.00
C:\WINNT\system32\KERNEL32.dll 4.00
C:\WINNT\system32\WS2_32.dll 4.00
C:\WINNT\system32\MSVCRT.dll 6.10.8293.0
C:\WINNT\system32\USER32.dll 4.00
C:\WINNT\system32\GDI32.dll 4.00
C:\WINNT\system32\ADVAPI32.dll 4.00
C:\WINNT\system32\RPCRT4.dll 4.00
C:\WINNT\system32\WS2HELP.dll 4.00
C:\WINNT\system32\comdlg32.dll 4.00
C:\WINNT\system32\SHELL32.dll 4.00
C:\WINNT\system32\COMCTL32.dll 5.81
C:\WINNT\System32\WINSPOOL.DRV 4.00
C:\WINNT\system32\ole32.dll 4.00
C:\WINNT\System32\OLEPRO32.DLL 5.0.4277
C:\WINNT\system32\OLEAUT32.dll 2.40.4277
C:\WINNT\system32\VERSION.dll 4.00
C:\WINNT\system32\LZ32.dll 4.00
C:\WINNT\System32\oledlg.dll 1.0
C:\WINNT\System32\IMM32.dll 4.00
C:\WINNT\System32\MSVCIRT.dll 6.00.8168.0
E:\pb80\Shared\PowerBuilder\PBDWE80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBDTS80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBDWP80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBSQL80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBLIB80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBDEV80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBORC80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBAPL80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBUDO80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBSCR80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBWED80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBDPP80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\PBEAS80.dll 8.0.00.3113
E:\pb80\Shared\PowerBuilder\pbweb80.dll 8.0.00.3113
E:\pb80\SHARED~2\Web Targets\WtGenericServ80.dll 1, 0, 0, 1
C:\WINNT\system32\WININET.dll 5.50.4522.1800
C:\WINNT\system32\SHLWAPI.dll 5.50.4522.1800
C:\WINNT\system32\TAPI32.dll 4.00
C:\WINNT\System32\mpr.dll 4.00
C:\WINNT\System32\ntlanman.dll 4.00
C:\WINNT\System32\NETUI0.dll 4.00
C:\WINNT\System32\NETUI1.dll 4.00
C:\WINNT\system32\NETAPI32.dll 4.00
C:\WINNT\system32\NETRAP.dll 4.00
C:\WINNT\system32\SAMLIB.dll 4.00
C:\WINNT\System32\rpcltc1.dll 4.00
E:\pb80\SHARED~2\Web Targets\WtViewSrvc80.dll 1, 0, 0, 1
E:\pb80\SHARED~2\Web Targets\WtDataObj80.dll 1, 0, 0, 3050
E:\pb80\SHARED~2\Web Targets\pswedit70.dll
C:\WINNT\System32\MFC42.DLL 6.00.8168.0
C:\WINNT\System32\ODBC32.dll 3.510.4202.0
C:\WINNT\System32\MSVCP50.dll 5.00.7051
C:\WINNT\System32\ATL.DLL 3.00.8449
C:\WINNT\System32\odbcint.dll 3.510.4202.0
E:\pb80\SHARED~2\WEBTAR~1\WTCURR~1.DLL 1, 0, 0, 3050
E:\pb80\SHARED~2\WEBTAR~1\WtLang80.dll 1, 0, 0, 3050
E:\pb80\SHARED~2\WEBTAR~1\WTCOMP~1.DLL 1, 0, 0, 3050
C:\WINNT\System32\msjava.dll 5.00.3316
C:\WINNT\System32\VMHELPER.DLL 5.00.3316
C:\WINNT\System32\JIT.DLL 5.00.3316
C:\WINNT\System32\javart.dll 5.00.3316
C:\WINNT\system32\MSIDLE.DLL 5.50.4522.1800
C:\WINNT\System32\ntshrui.dll 4.00
C:\WINNT\System32\IMAGEHLP.DLL 4.00
C:\WINNT\System32\psapi.dll 4.00



CR:231482
CR Number:   231482
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Feb 2001 Not a Bug
Description
Retrieve fails on SYBASE IQ database when it is based on a LIKE clause in a retrieval argument.
ODBC/JDBC Interface
One will get a Datawindow Error :
Select Error: SQLSTATE=S1000
[Sybase][ODBC Driver][Adaptive Server Anywhere]General error: the pattern argument in a like

predicate must have string datatype.
Error happens in developement and runtime.
Happens when retrieve is based on a argument and using a LIKE clause. If you hardcode the

value in the LIKE clause there is no error.

This is indeed an IQ bug : ASIQ 12.4.2 does not support using a parameter for the pattern of a "Like" predicate in the Where clause - in 12.4.2 this is required to be a constant. Support for using a parameter in this part of the SQL grammar has been added in 12.4.3.



CR:231498
CR Number:   231498
Product Name:   PB Enterprise
Product Component:   DB Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Sep 2001 Fixed
Description
When creating a view in PB 7.0.3 and you want to
add a column alias, pb will give an error. Depending on what database
that you are connected to it will either give a syntax error "Incorrect syntax
near ')' or ora-00904 Invalid column name.

While trying to create the column alias and you try to tab to the alias field,
pb won't let you and you cannot enter anything in the field.

Problem happens for syc,o84 and mss.



CR:231565
CR Number:   231565
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 4
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Sep 2001 Fixed
7090 06 Jul 2004 Not reproducible with latest version of the product available as of Resolution Date
Description
When Deleting a target in the system tree view it will be not removed from the list.



CR:231566
CR Number:   231566
Product Name:   PB Enterprise
Product Component:   Edit Mask
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 4
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Would like to have the possibility to configure the number/date/currency/ formats without relying on the registry settings, ie. that PB has a switch where it can either decide to get the information out of the registry (as it works now) or from eg a ini file.



CR:231576
CR Number:   231576
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:
Customer would liked the window display that was in PB 6.x in position tab in window properties. He would like that to be re-introduced in PB 8.

For example, select a window/properties/position. In pb 6.x, there was a graphical display to increase the
size of a window. When it was increased, it automatically increased the size of the x and y coordinates.
Customer would like to see this feature in pb 8.0.



CR:231671
CR Number:   231671
Product Name:   PB Enterprise
Product Component:   DB Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Sep 2001 Not reproducible with latest version of the product available as of Resolution Date
Description
Wrong numeric Width property column is displayed. For example
When a column is created as numeric width=6 and Dec=2, when the table is displayed later the displayd width is
width=8 and Dec=2.



CR:231695
CR Number:   231695
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
If you assign a column of a nested dw to a DWObject varibale and then you do call the print() function to the dw / ds Pb causes a gpf. See code below:
DWObject ldwo_test
ldwo_test = dw_1.Object.d_nest.Object.dept_name
dw_1.print()

Workaround:
add "dummy assignment"
ldwo_test = dw_1.Object.d_nest.Object.dept_name
ss = ldwo_test.primary[1]
dw_1.print()
Workaround Description
 add "dummy assignment"
ldwo_test = dw_1.Object.d_nest.Object.dept_name
ss = ldwo_test.primary[1]
dw_1.print()



CR:231722
CR Number:   231722
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10049 25 Feb 2004 Fixed
Description
After PB Jag component has fatal error, Jaguar still serves up the instance.
Verified fixed in 7.0.3 build 10049
Workaround Description
 The workaround is to not pool the component. This works of course because it creates a new instance every time. Which is also the problem; no reuse and no scalibility.



CR:231828
CR Number:   231828
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10048 27 Feb 2001 Fixed
Description
When client formatting is turned on for a html page
and a format is used on a number, item validation errors will appear inconsistently.

For example, the html page has setweight(true,true,true,true,true) set. A column
has a format of #,#00 set. When you alt tab to another application and then
alt tab back into the browser and then click on another field to give focus back
to the browser, a validation error will appear.

If you just call up the the page and tab thru the fields, than no problem. No validation
errors will appear.

If you set the setweight to (true,true,true,true,false), than no problems. The inconsistency
appears to be in the clientformatting property.
Workaround Description
 Turn off client formatting for the datawindow.



CR:231832
CR Number:   231832
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
24 Jan 2001 Presently Not Targeted For Any Future Release Of This Product
Description
Now that library lists are stored in relative paths, applications that used to get absolute paths from the PB.INI need updating, new functions would make this easier.

Many utility programs, read the library
list from the pb.ini file. The workspace and target files use relative
paths so determining the exact full path of a file would take a lot of code.

I would like to suggest adding two new functions. One would take the
argument of a workspace filename. It would return a string array with the
full path name of pb target files. Another function would take the
argument of a target filename. It would return the full path library list
in a string just like the pb.ini file has in earlier versions.



CR:231876
CR Number:   231876
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Aug 2001 Not a Bug
Description
Cannot have control names of inherited visual custom user object to be the same as a control on the object will get the following error
This object has duplicate control names. Ancestors and descendants must have the unique control names. Do you want to reset the names?





--------------------------------------华丽的分割线-------------------------------------------------------------------------

Sybase SQL Anywhere数据库恢复工具ReadASADB:

之前就已经研发成功了能够从Sybase SQL Anywhere的DB文件中恢复数据的工具: ReadASADB。
此工具支持ASA v5.0, v6.0, v7.0, v8.0, v9.0, v10.0, v11.0, v12.0, v16.0, v17.0等版本。
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具。
恢复Sybase SQL Anywhere的工具在国内处于领先水平。

Sybase SQL Anywhere数据库恢复工具ReadASADB功能
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具
  1. 适用于所有的SQL Anywhere版本    包括:5.x,6.x,7.x,8.x,9.x,10.x,11.x,12.x,16.x,17.x
  2. 适用于所有的UltraLite版本
  3. 能够恢复出来表结构和数据
  4. 能够恢复自定义数据类型
  5. 能够恢复存储过程等对象的语法
  6. 能够导出到目标数据库
  7. 能够导出到SQL文件并生成导入脚本
  8. 支持多种字符集,包括:cp850、cp936、gb18030、utf8等
  9. 能够恢复未加密或者简单加密类型的数据
  10. 简单易用
  11. 限制:不支持AES加密的数据文件
请参考:研发成功了从Sybase SQL Anywhere的DB文件上恢复数据的工具
            SQL Anywhere数据库非常规恢复工具ReadASADB使用介绍

Sybase SQL Anywhere数据库恢复工具ReadASADB适用场景

各种误操作:

  1. 误截断表(truncate table)
  2. 误删除表(drop table)
  3. 错误的where条件误删数据
  4. 误删除db或log文件
  5. 误删除表中的字段

Sybase SQL Anywhere数据库恢复工具ReadASADB的应用场景:

1.因为物理磁盘故障、操作系统、系统软件方面或者掉电等等原因导致的Sybase SQL Anywhere数据库无法打开的情况;
2.误操作,包括truncate table,drop table,不正确的where条件导致的误删除等;
Sybase SQL Anywhere无法打开时,比较常见的错误是:Assertion failed。
如:
1、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Checkpoint log: invalid bitmap page -- transaction rolled back
2、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Page number on page does not match page requested -- transaction rolled back
3、Internal database error *** ERROR *** Assertion failed:200502 (9.0.2.2451) Checksum failure on page 23 -- transaction rolled back
4、File is shorter than expected
5、Internal database error *** ERROR *** Assertion failed: 201116 Invalid free list index page found while processing checkpoint log -- transaction rolled back
6、*** ERROR *** Assertion failed: 51901 Page for requested record not a table page or record not present on page
7、*** ERROR *** Assertion failed: 201417 (7.0.4.3541) Invalid count or free space offset detected on a table page
8、Internal database error *** ERROR *** Assertion failed: 201425 (8.0.3.5594) Invalid count or free space offset detected on a free list page -- transaction rolled back.
9、Internal database error *** ERROR *** Assertion failed: 100702 (8.0.1.2600) Unable to modify indexes for a row referenced in rollback log -- transaction rolled back


-------------------------------------------------------------------------------------------

Sybase ASE数据库恢复工具READSYBDEVICE:

一个不依赖数据库管理系统、直接从Sybase数据库设备文件上提取数据的业内领先的恢复工具!
能够从损坏的Sybase ASE设备文件(.dat)上提取数据的非常规恢复工具。

Sybase ASE数据库恢复工具READSYBDEVICE的主要功能:

  1. 被勒索病毒加密数据文件及备份文件情况下的恢复;
  2. 系统崩溃只剩下数据文件的情况下的恢复,甚至数据库文件不存在而只有损坏的备份文件情况下的恢复;
  3. 因断电、硬盘坏道等造成数据库文件损坏情况下的恢复;
  4. delete数据恢复、误update数据恢复、误删除表(drop)恢复、误truncate表恢复 等;
  5. 各种Sybase内部系统表损坏、索引错误的修复;
  6. master数据库损坏而无法正常运行情况下的恢复;
  7. Sybase数据库被标记为可疑,不可用等情况的恢复;
  8. Sybase数据库中数据文件内部出现坏块情况下的恢复;
  9. Sybase数据库无数据文件但有日志文件的情况下的恢复;
  10. Sybase数据库只有数据文件无任何日志文件的情况下的恢复;
  11. Sybase数据文件被误删除情况下的碎片提取恢复;
  12. 磁盘阵列上的Sybase数据库被误格式化情况下的数据库恢复;
  13. 数据库sysobjects等系统表损坏无法正常应用情况下的恢复;
  14. Sybase数据库还原数据库出现失败情况下的恢复;
  15. Sybase数据库只剩下损坏的备份文件情况下的恢复。

Sybase ASE数据库恢复工具READSYBDEVICE支持的版本:

Sybase ASE 11.0.x,11.5.x,11.9.x,12.0.x,12.5.x,15.0.x,15.5.x,15.7.x,16.0.x


-------------------------------------------------------------------------------------------

SQL Server数据库恢复工具SQLRescue:

一个不依赖数据库管理系统、直接从SQL Server数据库文件上提取数据的业内领先的恢复工具!
能够从损坏的SQL Server数据库文件(.mdf)上提取数据的非常规恢复工具。

SQL Server数据库恢复工具SQLRescue的主要功能:

  1. 系统崩溃只剩下数据文件的情况下的恢复,即无日志文件或者日志文件损坏情况下的恢复;
  2. 断电导致数据库文件损坏情况下的恢复;
  3. 硬盘坏道造成数据库损坏情况下的恢复;
  4. 数据文件内部存在坏页情况下的恢复;
  5. 企业管理器误删除数据表记录,管理软件误删除数据表记录的恢复;
  6. 并闩锁错误、格式化、误删除后导致软件不能使用的情况;
  7. 无法读取并闩锁页sysindexes失败情况下的修复;
  8. 数据文件被误删除情况下的碎片提取恢复;
  9. 系统表损坏、索引错误、误删除数据库表、删除记录的数据找回;
  10. master数据库损坏而无法正常运行情况下的恢复;
  11. 数据文件无法附加情况下的数据恢复;
  12. 数据库被标记为可疑,质疑,不可用等情况的恢复;
  13. 数据库sysobjects等系统表损坏情况下的恢复;
  14. 数据被误(drop、delete、truncate)删除表数据的恢复,误update后的数据恢复等;
  15. 还原时报一致性错误,错误823等情况下的数据恢复,各种错误提示的数据库文件修复;
  16. 数据库被误格式化等情况下的数据库恢复;
  17. 日志收缩造成数据库损坏情况下的恢复;
  18. 仅剩损坏的备份文件情况下的恢复。

SQL Server数据库恢复工具SQLRescue技术特点:

只要SQL Server数据库的数据文件存在,我们就有办法帮您从数据文件中找回重要数据。
  1. 从数据文件中直接恢复数据
  2. 不能附加时直接恢复数据并生成新的数据库
  3. 系统表损坏的数据库修复
  4. 快速修复SQL 823错误、连接中断错误

SQL Server数据库恢复工具SQLRescue支持的版本:

Microsoft SQL Server 7.0, 2000, 2005, 2008, 2008R2, 2012, 2014, 2016, 2017,2019。
+-------------------------------------华丽的分割线-------------------------------------------------------------------------