提供7*24专业Sybase数据库远程及现场技术支持,Sybase ASE及Sybase SQL Anywhere数据库修复服务,
请联系电话: (微信),QQ: 289965371!
We supply technical support for Sybase ASE and Sybase SQL Anywhere, also have many years of experience in recovering data from damanged Sybase devices.
Please contact us:
Phone:
Wechat: 13811580958
QQ: 289965371 联系我们获取数据库技术支持!
Email: 289965371@qq.com
扫描下方微信,联系我们:
扫描雨翰数据恢复官方微信获取专业数据库恢复服务

 

随着Sybase被完全整合到SAP下,Sybase原来的支持网站被SAP Support Portal取代。
只有购买了SAP服务的用户才能使用账号登录SAP Support Portal进行介质下载、补丁升级、报Incident等。
考虑到Sybase数据库的初学者或者没有购买原厂服务的Sybase客户情况,现提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息。
在SAP Support Portal网站或者google上搜索Targeted CR List for ASE,可以看到针对不同版本的CR(CR表示Change Request)简单描述信息列表。
需要注意的是:Targeted CR List for ASE列出的CR虽然绝大多数是BUG,但有一些是更改需求。
以下提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息!

如有问题,请联系我!

QQ :289965371 联系我们获取数据库技术支持!
Email:
不仅仅包括BUG的详细描述信息,还包括首次报告BUG的平台、数据库版本以及BUG修复历史过程;有些BUG还提供了Workaround来临时解决该BUG带来问题。

 

CR:227520
CR Number:   227520
Product Name:   PB Enterprise
Product Component:   Install
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 3 28 Dec 2000 Fixed
Description
PB 8 Beta 2 buidl 2051 :
1. Run setup.exe for Beta2_2051. Go through custom install.
2. Select 'Native Database Interfaces' and click 'Change'.
Under 'Select Sub-components' , Oracle 8.x native driver is described as "Oracle 8.0.4 / 8.0.5". It should rather say 8.0.4+/ 8i+ or similar as its good for 8.0.5 and later versions.

3. Click continue - next - next until you reach 'Start Copying Files' screen which gives you a summary of the options you chose to install.
Under Native Database Interfaces you will find
" Oracle 8.x Interface (O84)
Oracle 8.0.4/8.0.5"
This is a repetition.



CR:227590
CR Number:   227590
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Memory leak with ADOResultset generated from datastore resultset



CR:227609
CR Number:   227609
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Nov 2000 Third Party Problem
Description
PB 8 build 3009, PVCS 6.7
Select Entry | Source Control | Advance Options or Select Entry | Source Control | Run PVCS Source Control
both of them will open the PVCS Options window, from there one can go into VM but not directly from the Run PVCS Source Control menuitem.
If you look at the same menuitems when connected to Visual SourceSafe the Run VSS opens VSS manager and the advance options shows the Options, two seperate menus have two seperate funcitonalities.



CR:227613
CR Number:   227613
Product Name:   PB Enterprise
Product Component:   DW Synchronization
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
GetFullState/SetFullState fails to capture OCX datawindow completely. Works fine as a regular datawindow, but no graph appears when using GetFullState/SetFullState.



CR:227615
CR Number:   227615
Product Name:   PB Enterprise
Product Component:   Menus - Runtime
Status:   Closed
OS:   Microsoft Windows 98
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
The design is to create a menu which has 1 menu item, 1 second level sub menu item and 1 third level sub menu item. The menu is associated with a window of type main!

This scenario has a script which causes the SECOND level sub menu item to lose focus e.g. messagebox(). On Win98 operating system, PB will gpf in USER.EXE (in development environment and runtime);
On NT4, this scenario does not gpf.
[ From PB help:-
Because MessageBox grabs focus, you should not use it when focus is changing... ]
The gpf on Win98 does not occur if the sub menu script keeps focus.
Workaround Description
 Place any script which would cause the menu item to lose focus in lowest level of sub menu e.g. if menu levels 1, 1.1, 1.1.1 - then place script in lowest level i.e. 1.1.1 for minimal event message queue interference.



CR:227652
CR Number:   227652
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
01 Mar 2001 Fixed
Description
OLE scripting against Word 6 in German. When using german commands containing Umlaute, the script will not compile giving a C0031 syntax error.
Workaround Description
 Use the aquivalent english commands



CR:227658
CR Number:   227658
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 3.1 3021 28 Feb 2001 Fixed
Description
PB 8 build 30009 :
When using PBNative as Source Management tool, it should populate the user and Storage Location automatically depending on the last one when using the workspace. It comes up as blank.



CR:227721
CR Number:   227721
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Solaris 2.6
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Mar 2004 EOL'd version. Not to be Fixed.
Description
Jaguar only finds htmldw.js is it exists in the folder Jaguar is started from. When starting Jaguar outside of $JAGUAR/bin you receive error: DW_LibMain() - open htmldw.js: No such file or directory
CdwHTMLRenderer::loadTemplate() -g_lpstrWebDWRsrcBuf NULL: No such file or directory



CR:227761
CR Number:   227761
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Nov 2000 Fixed
Description
When a line of script has a breakpoint associated with it and the code is selected and cut, PB gpfs.



CR:227767
CR Number:   227767
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Nov 2000 Duplicate
Description
In PB 7 multiple windows (or other objects) can be opened simultanously. When having more than 15 windows open at the same time (sometimes less) PB just disappears.



CR:227800
CR Number:   227800
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
09 Mar 2001 Fixed
Description
According to the documentation the PrintSetPrinter() PowerScript command should return 1 is successful and -1 if an error occurs. It returns 0



CR:227861
CR Number:   227861
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
27 Feb 2001 Not a Bug
Description
PB 6 & 7: Problem displaying certain Universe Condense font characters in an sle, text box. Worked okay on the text of a button. The characters do appear properly in the properties page.



CR:227875
CR Number:   227875
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10040 25 Feb 2004 Fixed
Description
In a HTML DW, a long (or ulong) column keyed with a leading 0 is replaced by a dummy value when the column loses the focus.
For instance, 0700 gives 448, 08 gives 0, 0777 gives 511.



CR:227877
CR Number:   227877
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Mar 2004 EOL'd version. Not to be Fixed.
Description
PB7: Column name specification field not getting updated after changing property



CR:227888
CR Number:   227888
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
06 Dec 2001 Not a Bug
Description
Close of the window which is of type Response! causes pb to crash , the crash handler file is available in the zip file.In debug the crash seems to be happening after successfull execution of the open of the response window.
The response window in turn calls a popup window which has a OLE control on it and a dw control (this dw control has 6 ole controls on it) All the OLE controls used here are the Pegasus Image OCX.
w_test_parent -
Clicked event of the button - Open(w_test)
w_test -
Clicked event of the button - Open(w_notice_printing) & script to load the ole on the window and dw.

PB will not crash if atmost 2 ole controls are populated in the dw(parent window of the window containing dw is Response!). OR if the window is of type Main! then there is no problem with the number of OLE Controls being populated. Looks like there is some kind of limit when using a Response window in terms of memory cache, which does not get released at the appropriate time.

This is NOT a PB BUG :
" When a child window of a Response! window is closed, the child window's "garbage" (unused objects) are "piled onto" the garbage bin of the parent Response! window. If the parent window is not a Response! window, then garbage collection is performed when the child window is closed. "
You should force GarbageCollect() in the close event of the child window.
Workaround Description
 Use Main! window instead of Response! type window for the parent window



CR:227940
CR Number:   227940
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Mar 2004 EOL'd version. Not to be Fixed.
Description
This problem is a regression and occurs in the development environment object painter

e.g. Window painter, UO painter, Menu painter.

For example, in any of the object painters (mentioned above), there is a "Script pane" there are 3 dropdownlistboxes :-

- Object/Functions/Declares

- Script/Declare Type

- Ancestor/Descendant



The "Ancestor/Descendant" ddlb is disabled after the save object operation.

This failure happens for ALL objects which ARE inherited and OVERRIDE ancestor functions:-

-Menu

-Window

-User object



The impact is that the PB developer cannot switch to ancestor nor descendant script.

PB6.x: N/A, feature not available in this release.
Workaround Description
 Change focus from the function and then return to it e.g. Toggle "Object/Functions/Declares" ddlb to a different section name from (Functions). Return to section name (Functions). "Ancestor/Descendant" ddlb is now enabled.



CR:227963
CR Number:   227963
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Unable to tab from one field to another in
third party ocx. The up,down arrows do not work either. When
positioning the mouse in a field, you can enter data but you cannot
tab thru the fields.



CR:227995
CR Number:   227995
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
find/replace in the window scripts painter does not close with ESC key



CR:228003
CR Number:   228003
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
OLE Browser does not show up COM server when the Inproserver32 entrie has
file name such as %SystemRoot%\filename.dll
Workaround Description
 Modify the Inprocserver32 by setting the full path without using environment varaiables



CR:228006
CR Number:   228006
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
If an expression is set on the visible property of a column querymode ignores the column value in the where clause, ie. query mode does not work.
Workaround Description
 Code the expression evaluation in script.



CR:228025
CR Number:   228025
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
24 May 2001 Fixed
27 Dec 2000 Fixed
Description
When in the dw painter and you try to change
the value of a graph under the "data" tab, pb will crash.
Works ok in PB 6.5.1 and 8.0.



CR:228091
CR Number:   228091
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10067 25 Feb 2004 Fixed
Description
The netscapelayers property is not
formatting multiple datawindows on a page. First
dw is formatted but subsequent dw's are not. Using
the following format:


ls_ns = "datawindow.htmlgen.NetscapeLayers='yes'"
ls_ret = dw.Modify( ls_ns )



CR:228104
CR Number:   228104
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
12 Mar 2001 Fixed
12 Mar 2001 Fixed
Description
A crosstab datawindow that has a column
with a dddw will gpf in the dw painter when you select
retrieve. Happens in pb 8.0 (build 2055). No problems
if column has no dddw associated with it.



CR:228122
CR Number:   228122
Product Name:   PB Enterprise
Product Component:   DW DDDW
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 3 13 Mar 2001 Fixed
Description
PB8 Beta2: Column validation error occurs in 8.0 and not in 7.0 in a shared datwindow dddw column on an insertrow.



CR:228125
CR Number:   228125
Product Name:   PB Enterprise
Product Component:   DataBase
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 EBF1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Dec 2004 Not reproducible with latest version of the product available as of Resolution Date
Description
export of syntax of a table does not export Unclustered indexes.
Both db interfaces only Clustered indexes are exported , unclustered are not.



CR:228126
CR Number:   228126
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
1. Create a workspace and target.
2. Create a datawindow (any style).
3. Click on a column and bring the properties up under the general tab.
4. The enhancement request is for a new type of "Border" . See the dropdown options under the border. Customer would like to add a 'TopLine' as an opposite of already existing 'Underline'.

A 'topline' would make summary fields easier to differentiate (as a separator from rest of the fields) - e.g, totals or any other computed fields.



CR:228156
CR Number:   228156
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10049 25 Feb 2004 Fixed
Description
HTML Datawindow JavaScript Caching.The first click on a required column having a dddw as Edit property, fires an itemerror event claiming that the field is required. This happens with IE and not with Netscape.
Workaround Description
 Don't use javascript caching if possible or use Netscape if possible.



CR:228174
CR Number:   228174
Product Name:   PB Enterprise
Product Component:   Menus - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
When a toolbar item is the first item
and it is in a cascading menu and you dynamically
change the following properties:

this.m_tools.m_pencil.visible = false
this.m_tools.m_pencil.enabled = false
this.m_tools.m_pencil.toolbaritemvisible = false

The tool bar item still appears when running app. As soon
as you select another item, than that toolbar item
can no longer be seen. If you physcially move pencil
after glasses and rerun app, than pencil doesn't show up.
Workaround Description
 Physically move the order of the cascading menu so that the items
are will be change dynamically are not the first ones in the order.



CR:228223
CR Number:   228223
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
PB7 / PB8 Translation ToolKit. Datavalue of a DDLB (editstyle of a column) in a datawindow lost after translation

workaround:
add the datavalue after translation again
Workaround Description
 add the datavalue after translation again



CR:228239
CR Number:   228239
Product Name:   PB Enterprise
Product Component:   DW Wizards
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
08 Mar 2001 Fixed
Description
PB 8 build 3009
Create a new dw of type freeform, on the selection for border choose shadow box/3d lowered/3d raised for text and column , finish the dw , notice the text border does get reflected as requested during dw creation but the column border comes back as 'NONE'



CR:228240
CR Number:   228240
Product Name:   PB Enterprise
Product Component:   Project Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 Dec 2000 Fixed
Description
PB 8 build 3009
Description of Problem: When you build a project without a name (for the project), the output window shows as follows:
"---------- Deploy: Deploy of "
1. Create any small target application.
2. RMB the target and 'New - Project - Application'.
3. Choose an exe name and click build.
4. The output window displays " Deploy of " with no name.
It should contain some name such as the executable name itself.



CR:228242
CR Number:   228242
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Resizable property when set to True/False in script for OLE control does not change the border type to Resize/default
Workaround Description
 either use resize functions or set the property at design time depending on the need of the application.



CR:228272
CR Number:   228272
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 Dec 2000 Duplicate
Description
When adding or deleting a column from the datasource of a very large datawindow (many hundreds of columns)
an OUT OF MEMORY error can occur.
Work-around is to modify the datawindow by exporting it and making the changes in the exported source.



CR:228290
CR Number:   228290
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10049 09 Feb 2001 Fixed
Description
Cannot create table with col of size >255 for Varchar when using MSS driver.
create table gives error : The maximum width for varchar column is 255
In PB 7.03 and above, on trying to save the table it blanks out the column after the
messagebox and another messagebox saying Value for item required.
Create table is successfull using the ODBC driver (sqlsrv32.dll 3.70.08.20).



CR:228334
CR Number:   228334
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Customer would really like PB's tab control to expose TCS_BUTTONS style. In general it would be nice for PB's wrappers of common controls to expose all the styles available. To be more specifc, he is looking for the ability to add taskbar buttons - which when clicked, open up tabpages which inherently are of TCS_BUTTONS style.



CR:228335
CR Number:   228335
Product Name:   PB Enterprise
Product Component:   Target Wizards
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
The "..." for a browse button in the library search path dialog should show "Browse" and not the dots - its hard to locate and is not that intuitive to the user.

RMB the workspace and select 'New - Target - Existing application'. You will see this button in "Set library search path" screen. If you don't look carefully you could easily miss that it is even there. Please replace with a Browse button so that it is easier to use.



CR:228351
CR Number:   228351
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Paste Special Instance popup window isn't wide enough to display the entire variable name/s. There are scroll bars on the window, but it is annoying not to be able to see the full variable name and have to scroll to view prior to making your selection.



CR:228352
CR Number:   228352
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
01 Dec 2000 Fixed
Description
Drop down pick lists in the IDE should not restrict their width to the width of
the drop down control but instead display more/all of the text of each item in
the list.

Dropdown pick lists in IDE are limited in width to the control, but that obscures some of the information in the list... The lists should be allowed to be wider when expanded (like we allow for dddws)

This behavior occurs throughout the IDE, so it would be a big effort to locate all occurrences but all occurences should be addressed.



CR:228353
CR Number:   228353
Product Name:   PB Enterprise
Product Component:   WT - Wizard - 4gl
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11 Jan 2001 Not reproducible with latest version of the product available as of Resolution Date
Description
Cannot add an ActiveX component to a web page in HTML editor - nothing happens



CR:228361
CR Number:   228361
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
20 Aug 2001 Presently Not Targeted For Any Future Release Of This Product
Description
Property fields of objects with integer types allow values higher than 32767 up to eleven digits to be entered. However, because they are integers after tabbing out of the field 32767 is entered.

This is because all the object properties are of type integer. The customer feels that the fields in the
properties view should only accept valid input and not revert to this value if larger numbers are entered.



CR:228370
CR Number:   228370
Product Name:   PB Enterprise
Product Component:   Query Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Datawindows that contain unions and dw was desinged in syntax mode. when tries to open in C3 or C4, dw ok but sql gpfs. If takes text syntex and edits () he can paste into sql



CR:228429
CR Number:   228429
Product Name:   PB Enterprise
Product Component:   Workspace and Targets
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 4 4114 14 Feb 2001 Fixed
Description
PB8 Beta2: Crash when double clicking HTML page in system tree to edit



CR:228435
CR Number:   228435
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Feb 2001 Presently Not Targeted For Any Future Release Of This Product
Description
Description of Problem: 4GL web page elements are not centered when viewed with Netscape browser

OS: Any
Version and Build #: 8.0 2051
16 bit/32 bit: 32
Database/Driver File/Version: N/A

Comments:
When viewing the source, it appears the <P align=center> tags are in the right place, but they don't seem to be interpreted by Navigator 4.7 correctly. Could be considered a navigator bug, but we might be safer using a DIV tag which does work for both IE and Netscape

Step-By-Step Instructions:
1. Add Target1.pbt target to an existing workspace
2. Configure a deployment for the target to a dynamo website
3. Deploy the target
4. View the page untitled.html in an IE browser and in Netscape and you'll notice how all the controls except for the static text are NOT centered.

Test Case (zip file) Name: 41075700.zip



CR:228458
CR Number:   228458
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
OpenChannel Runtime function and its behavior.
If I have the following script :
long ll_ret
ll_ret = OpenChannel( "","SendMail", Handle(parent) )

The applname argument for the function is null in that case everytime this code is executed a new handle number is returned into ll_ret instead of a -1 or some other error.



CR:228461
CR Number:   228461
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
PowerBuilder hangs on trying to re-deploy a PB Service component that is running.
Workaround Description
 You need to use Jaguar Manager and remove the service component from the server property: com.sybase.jaguar.server.services. Bounce Jag server. Re-deploy the service component.



CR:228491
CR Number:   228491
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Aug 2001 Fixed
Description
When using rtrim in a computed column (example converts a date from 2/2/2000 to February 2, 2000 in the
back end) the results get truncated. This works in sql and the db administrator.



CR:228521
CR Number:   228521
Product Name:   PB Enterprise
Product Component:   DB DirectConnect
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
10045 05 Aug 2003 Fixed
Description
PB 7.03 SQLCA values returned from RPC handled different in PB 5 & PB 7
Workaround Description
 See resolution for complete instructions.



CR:228531
CR Number:   228531
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.1 1274 13 Mar 2001 Fixed
Description
Customer has a long list of distinct Modify function statements, and they get part way through the modifys and then get an "access violation" (0xc0000005 address 0x105ca00a). Reproduced in small sample application after about 490 simple modifies. This was addressed but not fixed in CR 205097.



CR:228538
CR Number:   228538
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
An error in a dot notation to a nested dw object at run time fails to fire Error event.



CR:228613
CR Number:   228613
Product Name:   PB Enterprise
Product Component:   DB DirectConnect
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
27 Feb 2001 Fixed
Description
PB7.02 - Calling RPC results in results pending error



CR:228619
CR Number:   228619
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10037 25 Feb 2004 Fixed
Description
Cannot create c:\temp\...pbd when deploying to EAServer



CR:228621
CR Number:   228621
Product Name:   PB Enterprise
Product Component:   DW SaveAs
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Jun 2001 Fixed
Description
VM Size jumps by about 500M on a DW SaveAs to a WMF at random in pb dev environment causing incomplete data to be saved if you have a column with autosizeheight set to true.
If you have a column whose autosizeheight is set to true and in pb dev run sometime on the DW SaveAs the VM Size will jump as mush as 500M which causes no error but the data supposed to be in the column with the autosizeheight does not get saved. This behavior can be created but is very random in pb development. Once this happens the memory i snot released until you physically shut down pb, just shutting the application does not work.
If you create an exe you can reproduce the VM Size jump on the very first saveas.
I have tried SaveAs excel/txt/htmltable and was not able to repro the memory jumps, it only seems to be related to WMF! file.
In PB 7 there is no such memory jumps on the SaveAs.
In the customer's case he gets a dr watson, I was not able to repro the dr watson, in my case the VM size went about about 890M , I even tried opening a number of sheets and clicking on the save quickly but no change or error other than not saving data .



CR:228735
CR Number:   228735
Product Name:   PB Enterprise
Product Component:   DB Sybase System
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10070 18 May 2001 Not a Bug
Description
Sybase database interface:
Repeatedly creating new logins in the database painter can cause a crash, when the
login already existed.
Work-around :
To test if a user already exist, you can also use a select statement like:
select name from syslogins where name = <specified name>



CR:228747
CR Number:   228747
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Customer would like to see the Powerscript functions added to the Autoscript enabling.

See online help:
PowerScript reference>Statements, Events and Functions>Powerscript Functions
for a list of all the functions.



CR:228750
CR Number:   228750
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Suggestion to have a base class from which datawindow and datastore are both inherited - or perhaps inherit datawindow from datastore?



CR:228761
CR Number:   228761
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Please add an option to cancel out when opening a wrong workspace/target/pbl, etc If the user double clicks on the wrong library or directory then one has to wait for it to be completely displayed before being able to switch to the correct one. Especially in PB 8, the loading of the libraries is time-consuming.

Suggestion that this option could use the 'ESC' key or perhaps the 'Ctrl-C' combination.



CR:228770
CR Number:   228770
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.2 10047 22 Mar 2001 Fixed
Description
Repaint problems if HSplitScroll is selected and the dw control does not have a horizontal

scroll bar created at runtime.
The problems seems to be only if you have HorizontalSplitScroll + Grid/Tabular combination.
If it is grid then complete data is not seen in its entirity, if it is tabular then you see

an extra row half visible at the bottom of the control.
On unchecking the HSplitScroll box repaint is ok.

If the horizontal scroll is not there on the dw control because there is not enough data

horizontally to scroll in the control, then you will see the repaint problem and the tag to

pull the split scroll cannot be clicked to create a split in the control.
Workaround Description
 Workaround :
1) Turn Off HSplitScroll
2) Make sure the you have enough data horizontally in the dw control such that the horizontal scroll bar can be seen at runtime.



CR:228824
CR Number:   228824
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
UseFormat propertie is missed in describe of datawindow. Because UseFormat propertie is not included if doing descibe this can causes problems if using for instant the datawindow create() function.

Workaround:
add "editmask.UseFormat=yes" in datawindow syntax created by the describe() funktion
or
set the property dynamicly before retrieving -> dw.object.colomnname.editmask.UseFormat='yes'
Workaround Description
 add "editmask.UseFormat=yes" in datawindow syntax you got with describe
or
set the property dynamicly before retrieving -> dw.object.colomnname.editmask.UseFormat='yes'



CR:228830
CR Number:   228830
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 3 08 Mar 2001 Fixed
Description
Add the new file system functions to the Help under System Functions by Category>File Functions, the new printer functions to System Functions by Category>Print functions, etc...

The following functions:
-ChangeDirectory
-CreateDirectory
-DirectoryExists
-FileCopy
-FileMove
-GetCurrentDirectory
-RemoveDirectory
are listed under What's New>Miscellaneous>New PowerScript Functions
under the heading:
New File System Functions
they also need to be added to the Help under:
System Functions by Category>File Functions
Same is true for all the other functions listed under the "What's New" section.



CR:228834
CR Number:   228834
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Dec 2000 Fixed
Description
The online help indicates "String. Returns the current printer name". Actually, what it returns is the printer name, printer driver and port in a tab delimited string (as the PrintGetPrinters function does for the entire printer list)



CR:228835
CR Number:   228835
Product Name:   PB Enterprise
Product Component:   Function Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement request: add a system function: ChooseFont()
Just like there is now a ChooseColor() function, would like to have a ChooseFont() function



CR:228839
CR Number:   228839
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 3 08 Jan 2001 Fixed
Description
In on-line Help, position attribute of MailFileDescription object is marked as read-only, when in fact it is required to be set to properly send a message with multiple attachments.



CR:228840
CR Number:   228840
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
GetFileOpenName ( title, pathname, filename {, extension {, filter } } )
should be updated to support everything that Win32 supports (setting the directory to start in, setting the default file name to use, and add support for the explorer style dialog with multi-file selection capability).

Enhancement request for GetFileOpenName function: Add the following functionality:
- start-in directory
- setting the default file name to use
- multi-file selection cap



CR:228842
CR Number:   228842
Product Name:   PB Enterprise
Product Component:   Menu Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
When a menu is inherited from a menu and saved as the same name as one of the submenu items PB hangs.



CR:228846
CR Number:   228846
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Columns in library painter can be hidden, but not reordered. Request is to allow this here and for all other cases where such tabular list views are used.

Assuming the WIndows Explorer list view paradigm, this is a capability provided there so we should be following tthe standard behavior.



CR:228870
CR Number:   228870
Product Name:   PB Enterprise
Product Component:   Migration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Oct 2004 Fixed
Description
Suggestion to streamline the migration process and eliminate one of the two steps at which you can specify additional libraries when migrating your application.

When migrating there are two separate points in the wizard where you can enter a library list? Can one be eliminated?

The two screens allowing you to do this have separate purpose, I think. One is for an existing application (which may or may not require migration) and the other is for specifically migration. However, in the case you do require migration from an existing application, it seems redundant and it should 'know' that it's already asked for library list info.



CR:228877
CR Number:   228877
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
08 Mar 2001 Duplicate
Description
When deleting directory through library painter, deletion fails with error "Cannot delete directory <name> due to items that were not able to be deleted." or an error saying that it could not be deleted because access is denied.
Additionally, the prompt to confirm deletion has a double entry for the directory if the directory you try to delete is at the root of the drive. When D:\pbldirectory is RMB and delete selected then when the confirmation box comes up the directory name will be duplicated and will show as D:\pbldirectory\pbldirectory.

If it is not supported to delete entire directories then the option should not come up and this should be documented.

Individual pbls are successfully deleted when deleted this way but not directories.



CR:228888
CR Number:   228888
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
19 Apr 2001 Not a Bug
Description
Documentation says, "When working in a painter, setting the font face name causes the correct font family to be selected." which seems to allude the fact that you change only FaceName to get the appropriate settings for FontPitch, FontCharSet, and FontFamily. PB7, however, allows you to change these independently. If we are disallowing that in PB8, then remove these items on the Font tab. Presently FontPitch, FontFamily, FontCharset are disabled in IDE.



CR:228957
CR Number:   228957
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:
Add an event to the vtrack and htrack controls that maps to
pbm_sbnthumbposition (Integer scrollpos) so that controls
will work with intellimouse.

Now you have to add this event manually to get the intellimouse to work.

From development on why the move event doesn't work with intellimouse:
Thumbwheels generate the same WM_HSCROLL/WM_VSCROLL
message but with a diffierent notification code as opposed to the
situation where the mouse button is used. The notification code is
stored in the low word of the WPARAM that comes with the Windows
message.

When the mouse button is used to drag the horizontal/vertical
scroll box, the windows message WM_HSCROLL/WM_VSCROLL
is sent to the scroll bar control with the notification code
SB_THUMBTRACK (value 5).

This notification is mapped by PowerBuilder to pbm_sbnthumbtrack.
Thus, if an event-handler function for pbm_sbnthumbtrack is
defined, it will be fired.

When the intellimouse's thumbwheel is used, the windows
message WM_HSCROLL/WM_VSCROLL is sent to the scroll bar
control with the notification code SB_THUMBPOSITION (value 4).

This notification is mapped by PowerBuilder to pbm_sbnthumbposition.
In the current example, no event-handler function for pbm_sbnthumbposition
exists. Therefore, the expected behaviour did not occur.



CR:228959
CR Number:   228959
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:
See cr 228957. Add an event to the w_trackbars/vtrack and htrack controls and map it
to the pbm_sbnthumbposition (integer scrollpos) so the the vtrack and htrack controls
will slide up and down when the intellimouse is used.

The new event will also need the following code:
dw_1.Object.DataWindow.Zoom = scrollpos
dw_1.Title = "Zoom is " + String ( this.Position ) + "%"

Once a new event is generated automatically for vtrack and htrack (see 228957) than only
the following code will need to be added from above.



CR:228961
CR Number:   228961
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 May 2001 Presently Not Targeted For Any Future Release Of This Product
Description
Enhancement Request:
Change the name of the printgetprinters() function to printgetprinterlist. It's too
close to printgetprint() and might cause confusion in the end.



CR:228981
CR Number:   228981
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Solaris 2.6
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Mar 2004 EOL'd version. Not to be Fixed.
Description
The pbdwrmt.pbl is included with PB 7.0 on windows.
If any changes are made and then the pbl is redeployed
to unix, the librarylist for the HTMLGenerator component in Jaguar shows up as $PBDWRMT.pbd.
This is a problem on unix because unix is case sensitive. The
pbd is deployed on unix in lower case. When running a htmldw, it cannot
find the pbdwrmt.pbd because the librarylist is $PBDWRMT.pbd.

If you look at the pbdwrmt.pbl thru windows explorer, it shows up in lowercase.
If you select the pbl thru pb, it shows up in upper case. The ms-dos name
is in upper case.

Workaround:Modify the librarylist under the HTMLGenerator component
and change PBDWRMT.pbd to pbdwrmt.pbd
Workaround Description
 Modify the librarylist under the HTMLGenerator component
and change PBDWRMT.pbd to pbdwrmt.pbd



CR:229028
CR Number:   229028
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.x Catalina
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 Fixed
Description
Java dataWindow (Power J)
======================
Documentation problem concerning the JAVA datawindow :
Property Datawindow.data.HTML does not contain Javascript but only HTML.



CR:229146
CR Number:   229146
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Solaris 2.6
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 Fixed
Description
The date format MMM or DDD does not work on PB/Solaris
Workaround Description
 Create a method which returns a date type and convert it to a string on the client side.



CR:229147
CR Number:   229147
Product Name:   PB Enterprise
Product Component:   Pipeline - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
01 Oct 2001 Fixed
Description
Calling Pipeline.Start() from a button and disabling the button (with this.enabled = false) before calling Start() causes access violation



CR:229181
CR Number:   229181
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   Solaris 2.6
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10040 25 Feb 2004 Fixed
Description
Using the new PBVM (Build 10037) and Jaguar 3.6, cannot
return data back to client. Only returns 1 row and it appears to be part of the
select statement.

Using a pb component in jaguar that retrieves data to a datastore. Data
retreived from datastore is 1 row. A getfullstate returns a blob to a pb client.
A setfullstate shows the data in the dw. Happens when Oracle 8.1.5 and 8.1.6
client is used. Used the libpbo8470x.so.



CR:229186
CR Number:   229186
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Large dataset retrieve in dw causes an "Out of memory" error
Workaround Description
 At runtime :
Just before the retrieve() is called try the following :
dw_1.Modify("datawindow.storagepagesize='LARGE'")
The problem still occurs in dw painter.



CR:229231
CR Number:   229231
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9.0 26 Oct 2005 Fixed
Description
The losefocus control of the ole container is not triggered when changing the focus from an ole container/control to a datawindow.
Effect:
When comming back to the control with back tab the focus will not be set into the editable region.



CR:229260
CR Number:   229260
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Solaris 2.6
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10041 20 Dec 2000 Fixed
Description
Jaguar 3.5 Server on Solaris , Core Dumps for Oracle 8.1.6 client



CR:229261
CR Number:   229261
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Solaris 2.6
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10039 14 Feb 2001 Fixed
Description
EAServer 3.6.1 PBVM 10037 on Solaris Crashes with Oracle 8.1.6



CR:229271
CR Number:   229271
Product Name:   PB Enterprise
Product Component:   Printing
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:
Customer would like to extend functionality of PrintSetPrinter to dynamically create a local profile for a printer if one does not exist.

PrintSetPrinter will change printers; however, customer would like capability to detect the fact that a UNC encoded printer path is not installed on the machine and have it automatically download the drivers and set up the printer defintion for you.

His rationale follows:

On WinNT and W2K, you can dynamically define a printer connection (the
related Windows API call is AddPrinterConnection):

http://msdn.microsoft.com/library/psdk/gdi/prntspol_7hgu.htm

All you pass is the name of the server and printer share. If the WinNT
or W2K machine doesn't have the printer drivers, it downloads and installs
them automatically from the machine hosting the share.

I don't believe that this is particularly important for client
applications. However, it would be an important feature for server based
applications, either native PB or EAServer hosted objects. A developer
shouldn't be required to create a local profile on the server for every
possible printer that a server based application may need to print to.

What I'm looking for is a version of the PrintSetPrinter function that
would take a UNC formatted servername/sharename argument, and dynamically
create a profile for that printer if one doesn't already exist, and of
course then make it the default. And, of course, if this call was made
from a Win9x client it should simply return an error.



CR:229300
CR Number:   229300
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
OS: Tested on NT 4.0/98
PB Version and Build: 6.5/7.02/7.03/8.0 Beta III
DB/DLL: PBVM

Comments:
Only happens with machine code.
Also reproduced with user events (posting or triggering)
Worked in PB 5, broken in PB 6.5
Workaround - Call Yield just before calling Trim

On 7.02 Build 9028 it gives the following crash in PBVM
0x1139F134 - 0x00000004 - Read error

On PB 8 Build 3033
0x10CNBF3c4 - 0x00000004 - Read error
Workaround Description
 - Call Yield() just before Trim() in the object function
- Use Pcode



CR:229312
CR Number:   229312
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Info from customer : I was starting to run my application (out of the IDE) and I got this error message. I have no idea what it means. (The app runs fine before and after this crash).



CR:229316
CR Number:   229316
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Dec 2000 Fixed
Description
Building and Deploying from a commandline' is a new feature in PB 8.0. The help instructions need to be more detailed. The section 'Building and Deploying from a commandline' talks about commandline parameters. However, it misses an important fact - that you have to first create and save a project object and only then you can deploy an application from commandline.

Step-By-Step Instructions: This is how it works;
You have to first create a project object and specify all options such as the exe name, machine code etc. Save the object in the pbl. RMB the target and under 'Deploy' tab make sure that this project object is
checked.
Finally, now when you run the commandline, PB starts up - deploys the project - shuts down.



CR:229317
CR Number:   229317
Product Name:   PB Enterprise
Product Component:   Application Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Dec 2000 Not reproducible with latest version of the product available as of Resolution Date
Description
PB 8 build 3033 :
Two behaviors that happen with Shift+F1 key when used in the application painter :
1) In the application painter type the letter 'O' and the hit Shift+F1, the help will not scroll to the first letter you chose for e.g O......
if you do it in say window script painter it will scroll to the first topic in the list that starts with an O.
2) in the application script painter if you type " Open(w_test)" and then move the cursor to somewhere between the O and the n of the word Open then you will see 2 help window pop, one that gives you description on the Open function and second that shows you the index of help.
If you do the same in the window script then only the Open function help pops up.



CR:229320
CR Number:   229320
Product Name:   PB Enterprise
Product Component:   UO Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB 8 Beta 2: ENHANCEMENT REQUEST: Painter enhancements/modifications



CR:229324
CR Number:   229324
Product Name:   PB Enterprise
Product Component:   MTS Integration
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB8 Beta2: Enhancement: Nice if all NVOs derived from the COM IDispatch interface



CR:229326
CR Number:   229326
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 Sep 2002 Not a Bug
25 Sep 2002 Fixed
Description
When a PB component (call it component B) running in Jaguar is called repeatedly from another PB component (component A - also running in Jaguar) the calling component (A) will hang when the properties of these components are set as described below.



The calling component (A) hangs after the call to the second component (B) tries to return control to the calling component method. The method is executed correctly and deactivate and destructor events are correctly fired in the second component (B) but component A never regains control.



As component A is frozen, component B is no longer called from component A but component B can still be called again from other components/clients. The problem is that component A can no longer be called from other clients. Jaguar must be restarted to use the component again



The component being called (B) must have the following properties to reproduce the problem:

- Automatic demarcation/deactivation selected

- Bind thread selected (Note that the same component called from a PB client app works)



Also component (A) must not be pooled.

I have only reproduced the problem when both components have ONLY the same properties (as described above for component B) checked.



CR:229393
CR Number:   229393
Product Name:   PB Enterprise
Product Component:   Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Aug 2001 Fixed
Description
edit mask control issue with the date edit mask dd/mm/yy.It's possible to enter a wrong value in the day mask. For instance 90/00/00. Validation of the first datemask is not working.
Failed in 6.5.1 #1240 and #1244;



CR:229504
CR Number:   229504
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.1 1278 19 Apr 2001 Fixed
Description
Dw with group crashes in preview when trying to advance to the next page. Happens only when the detail band is made slim to hide the columns below.

WA: make the columns very slim (in height) and then adjust the detail band to the columns ie. to a height of eg. 4.
Workaround Description
 make the columns very slim (in height) and then adjust the detail band to the columns ie. to a height of eg. 4.



CR:229516
CR Number:   229516
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
03 Mar 2005 Fixed
Description
When setting HTMLTable.Border=0 in grid dw it still shows a Border around the table. The TABLE tag will default back to BORDER=1.



Several workarounds possible:

Change the HTML output from the generate method on the fly:

1. Change the BORDER attribute to BORDER=0

2. Insert a CSS information for the dw on the page.
Workaround Description
 Several workarounds possible:

Change the HTML output from the generate method on the fly:

1. Change the BORDER attribute to BORDER=0



2. Insert a CSS information for the dw on the page.



CR:229529
CR Number:   229529
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Mar 2004 EOL'd version. Not to be Fixed.
Description
PB7 & PB8: mdihelp window crashes on close if Static Hyperlink has no URL



CR:229555
CR Number:   229555
Product Name:   PB Enterprise
Product Component:   Function Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Dec 2000 Not a Bug
Description
Using PB7.03, I created a duplicate function (trying to overload a function).
While adding the additional arguments, PB crashed. Does not happen consistently.

Attached is the crash handler dump.

Exception code: C0000005 ACCESS_VIOLATION
File Name: E:\Program Files\Sybase\Shared\PowerBuilder\PBVM70.dll
File Version: 7.0.3.10009
Fault address=1137B1B6 Section:Offset=01:0017A1B6

Registers:
EAX:FFFFFFFF
EBX:00000000
ECX:0012FAEC
EDX:04780300
ESI:00000000
EDI:01123C10
CS:EIP:001B:1137B1B6
SS:ESP:0023:0012FADC EBP:00000000
DS:0023 ES:0023 FS:0038 GS:0000
Flags:00010246

Call stack:
Address Frame Param0 Param1 Param2 Param3 Function Name
1137B1B6 00000000 00000000 00000000 00000000 00000000 0001:0017A1B6 E:\Program Files\Sybase\Shared\PowerBuilder\PBVM70.dll

OS version:
Windows NT 4.0, Build Number: 1381, Service Pack 5

Memory Status:
Total physical memory: 261168K
Available physical memory: 123900K
Total virtual memory usage: 139712K / 516224K
PowerBuilder virtual memory usage: 99048K / 2097024K

Loaded Modules:
E:\Program Files\Sybase\Shared\PowerBuilder\PB70.EXE 7.0.3.10007
C:\WINNT\System32\ntdll.dll 4.00
E:\Program Files\Sybase\Shared\PowerBuilder\PBSYS70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBCMP70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBVM70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\libjcc.dll
C:\WINNT\system32\WSOCK32.dll 4.00
C:\WINNT\system32\KERNEL32.dll 4.00
C:\WINNT\system32\WS2_32.dll 4.00
C:\WINNT\system32\MSVCRT.dll 6.10.8293.0
C:\WINNT\system32\USER32.dll 4.00
C:\WINNT\system32\GDI32.dll 4.00
C:\WINNT\system32\ADVAPI32.dll 4.00
C:\WINNT\system32\RPCRT4.dll 4.00
C:\WINNT\system32\WS2HELP.dll 4.00
C:\WINNT\system32\comdlg32.dll 4.00
C:\WINNT\system32\SHELL32.dll 4.00
C:\WINNT\system32\COMCTL32.dll 5.81
C:\WINNT\System32\WINSPOOL.DRV 4.00
C:\WINNT\system32\ole32.dll 4.00
C:\WINNT\System32\OLEPRO32.DLL 5.0.4514
C:\WINNT\system32\OLEAUT32.dll 2.40.4514
C:\WINNT\system32\VERSION.dll 4.00
C:\WINNT\system32\LZ32.dll 4.00
C:\WINNT\System32\oledlg.dll 1.0
E:\Program Files\Sybase\Shared\PowerBuilder\PBDWE70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBDTS70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBDWP70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBSQL70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBLIB70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBDEV70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBORC70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBAPL70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBUDO70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBSCR70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBWED70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\PBDPP70.dll 7.0.3.10009
C:\WINNT\System32\ettmr40.dll 4.2.0.2
C:\PROGRA~1\Logitech\MOUSEW~1\SYSTEM\LgMousHk.dll 9.10.53
C:\WINNT\system32\MSIDLE.DLL 5.50.4134.600
C:\WINNT\System32\mpr.dll 4.00
C:\WINNT\System32\NOVNPNT.DLL v4.11a PTF (980408) PTF
C:\WINNT\system32\NETAPI32.dll 4.00
C:\WINNT\system32\NETRAP.dll 4.00
C:\WINNT\system32\SAMLIB.dll 4.00
C:\WINNT\System32\CALWIN32.DLL 5.1.0
C:\WINNT\System32\CLNWIN32.DLL
C:\WINNT\System32\LOCWIN32.DLL
C:\WINNT\System32\NCPWIN32.dll
C:\WINNT\System32\NETWIN32.DLL
C:\WINNT\System32\CLXWIN32.DLL
C:\WINNT\System32\NLS\ENGLISH\NOVNPNTR.DLL v4.11 (970501)
C:\WINNT\System32\MSVCRT40.dll 4.20 - OS use only. DO NOT DISTRIBUTE
C:\WINNT\System32\MSVCIRT.dll 6.00.8168.0
C:\WINNT\System32\ntlanman.dll 4.00
C:\WINNT\System32\NETUI0.dll 4.00
C:\WINNT\System32\NETUI1.dll 4.00
C:\WINNT\System32\rpcltc1.dll 4.00
E:\Program Files\Sybase\Shared\PowerBuilder\pbwep70.dll 7.0.3.10009
E:\Program Files\Sybase\Shared\PowerBuilder\pbwei70.dll 7.0.3.10009
C:\WINNT\System32\ntshrui.dll 4.00
C:\WINNT\System32\IMAGEHLP.DLL 4.00
C:\WINNT\System32\psapi.dll 4.00



CR:229570
CR Number:   229570
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:

Customer request the ability to lock any listview in the library painter so that it does not refresh to any changes in the treeview. Customer wants some sort of locking mechanism that can be turned on\off so that he can make one or more listviews 'static' so that changes in the Tview do not refresh them.



CR:229632
CR Number:   229632
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement request for a "DirList()" system function that would be comparable to the PFC of_dirlist(filespec,filetype,dirlist)

The idea is to be able to get the directory list information without having to resort to a listbox. It would be a System function, like the other new directory System functions (CreateDirectory, ChangeDirectory, DeleteDirectory).
Compare to of_dirlist in the n_cst_filesrv_win32 object. That one takes an array of n_cst_dirattrib by reference to
pass the data back.
Instead of:
n_cst_filesrv inv_filesrv
f_SetFileSrv(inv_filesrv, TRUE)
inv_filesrv.of_dirlist ( yada, yada, yada )
f_SetFileSrv(inv_filesrv, FALSE)

I would just use:
DirList ( yada, yada, yada )



CR:229654
CR Number:   229654
Product Name:   PB Enterprise
Product Component:   UO - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   10.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Jul 2005 Fixed
03 Nov 2005 Fixed
Description
From the documentation for olecustomcontrol, information

from the externalexception and error events will be propagated to a runtimeerror object.



The source and description fields from externalexception are not accessible

via the try/catch mechanism. These two fields contain useful diagnostic

information by the ocx vendor.



CR:229665
CR Number:   229665
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
06 Aug 2004 Not a Bug
Description
PB8 Beta2: Windows 2000 input of Thai characters not displayed correctly



CR:229668
CR Number:   229668
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB8Beta2: Request that Autosize Height be available to group bands.



CR:229707
CR Number:   229707
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Depending on the Database used and the connection mode choosen, DropDownListBox does not show the Display value when the column's datatype is CHAR. (or VARCHAR).
The data value is shown instead.



CR:229728
CR Number:   229728
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Jan 2001 Not a Bug
Description
PB8 Beta3: Can't create DW based on a stored procedure with Oracle ODBC driver





--------------------------------------华丽的分割线-------------------------------------------------------------------------

Sybase SQL Anywhere数据库恢复工具ReadASADB:

之前就已经研发成功了能够从Sybase SQL Anywhere的DB文件中恢复数据的工具: ReadASADB。
此工具支持ASA v5.0, v6.0, v7.0, v8.0, v9.0, v10.0, v11.0, v12.0, v16.0, v17.0等版本。
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具。
恢复Sybase SQL Anywhere的工具在国内处于领先水平。

Sybase SQL Anywhere数据库恢复工具ReadASADB功能
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具
  1. 适用于所有的SQL Anywhere版本    包括:5.x,6.x,7.x,8.x,9.x,10.x,11.x,12.x,16.x,17.x
  2. 适用于所有的UltraLite版本
  3. 能够恢复出来表结构和数据
  4. 能够恢复自定义数据类型
  5. 能够恢复存储过程等对象的语法
  6. 能够导出到目标数据库
  7. 能够导出到SQL文件并生成导入脚本
  8. 支持多种字符集,包括:cp850、cp936、gb18030、utf8等
  9. 能够恢复未加密或者简单加密类型的数据
  10. 简单易用
  11. 限制:不支持AES加密的数据文件
请参考:研发成功了从Sybase SQL Anywhere的DB文件上恢复数据的工具
            SQL Anywhere数据库非常规恢复工具ReadASADB使用介绍

Sybase SQL Anywhere数据库恢复工具ReadASADB适用场景

各种误操作:

  1. 误截断表(truncate table)
  2. 误删除表(drop table)
  3. 错误的where条件误删数据
  4. 误删除db或log文件
  5. 误删除表中的字段

Sybase SQL Anywhere数据库恢复工具ReadASADB的应用场景:

1.因为物理磁盘故障、操作系统、系统软件方面或者掉电等等原因导致的Sybase SQL Anywhere数据库无法打开的情况;
2.误操作,包括truncate table,drop table,不正确的where条件导致的误删除等;
Sybase SQL Anywhere无法打开时,比较常见的错误是:Assertion failed。
如:
1、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Checkpoint log: invalid bitmap page -- transaction rolled back
2、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Page number on page does not match page requested -- transaction rolled back
3、Internal database error *** ERROR *** Assertion failed:200502 (9.0.2.2451) Checksum failure on page 23 -- transaction rolled back
4、File is shorter than expected
5、Internal database error *** ERROR *** Assertion failed: 201116 Invalid free list index page found while processing checkpoint log -- transaction rolled back
6、*** ERROR *** Assertion failed: 51901 Page for requested record not a table page or record not present on page
7、*** ERROR *** Assertion failed: 201417 (7.0.4.3541) Invalid count or free space offset detected on a table page
8、Internal database error *** ERROR *** Assertion failed: 201425 (8.0.3.5594) Invalid count or free space offset detected on a free list page -- transaction rolled back.
9、Internal database error *** ERROR *** Assertion failed: 100702 (8.0.1.2600) Unable to modify indexes for a row referenced in rollback log -- transaction rolled back


-------------------------------------------------------------------------------------------

Sybase ASE数据库恢复工具READSYBDEVICE:

一个不依赖数据库管理系统、直接从Sybase数据库设备文件上提取数据的业内领先的恢复工具!
能够从损坏的Sybase ASE设备文件(.dat)上提取数据的非常规恢复工具。

Sybase ASE数据库恢复工具READSYBDEVICE的主要功能:

  1. 被勒索病毒加密数据文件及备份文件情况下的恢复;
  2. 系统崩溃只剩下数据文件的情况下的恢复,甚至数据库文件不存在而只有损坏的备份文件情况下的恢复;
  3. 因断电、硬盘坏道等造成数据库文件损坏情况下的恢复;
  4. delete数据恢复、误update数据恢复、误删除表(drop)恢复、误truncate表恢复 等;
  5. 各种Sybase内部系统表损坏、索引错误的修复;
  6. master数据库损坏而无法正常运行情况下的恢复;
  7. Sybase数据库被标记为可疑,不可用等情况的恢复;
  8. Sybase数据库中数据文件内部出现坏块情况下的恢复;
  9. Sybase数据库无数据文件但有日志文件的情况下的恢复;
  10. Sybase数据库只有数据文件无任何日志文件的情况下的恢复;
  11. Sybase数据文件被误删除情况下的碎片提取恢复;
  12. 磁盘阵列上的Sybase数据库被误格式化情况下的数据库恢复;
  13. 数据库sysobjects等系统表损坏无法正常应用情况下的恢复;
  14. Sybase数据库还原数据库出现失败情况下的恢复;
  15. Sybase数据库只剩下损坏的备份文件情况下的恢复。

Sybase ASE数据库恢复工具READSYBDEVICE支持的版本:

Sybase ASE 11.0.x,11.5.x,11.9.x,12.0.x,12.5.x,15.0.x,15.5.x,15.7.x,16.0.x


-------------------------------------------------------------------------------------------

SQL Server数据库恢复工具SQLRescue:

一个不依赖数据库管理系统、直接从SQL Server数据库文件上提取数据的业内领先的恢复工具!
能够从损坏的SQL Server数据库文件(.mdf)上提取数据的非常规恢复工具。

SQL Server数据库恢复工具SQLRescue的主要功能:

  1. 系统崩溃只剩下数据文件的情况下的恢复,即无日志文件或者日志文件损坏情况下的恢复;
  2. 断电导致数据库文件损坏情况下的恢复;
  3. 硬盘坏道造成数据库损坏情况下的恢复;
  4. 数据文件内部存在坏页情况下的恢复;
  5. 企业管理器误删除数据表记录,管理软件误删除数据表记录的恢复;
  6. 并闩锁错误、格式化、误删除后导致软件不能使用的情况;
  7. 无法读取并闩锁页sysindexes失败情况下的修复;
  8. 数据文件被误删除情况下的碎片提取恢复;
  9. 系统表损坏、索引错误、误删除数据库表、删除记录的数据找回;
  10. master数据库损坏而无法正常运行情况下的恢复;
  11. 数据文件无法附加情况下的数据恢复;
  12. 数据库被标记为可疑,质疑,不可用等情况的恢复;
  13. 数据库sysobjects等系统表损坏情况下的恢复;
  14. 数据被误(drop、delete、truncate)删除表数据的恢复,误update后的数据恢复等;
  15. 还原时报一致性错误,错误823等情况下的数据恢复,各种错误提示的数据库文件修复;
  16. 数据库被误格式化等情况下的数据库恢复;
  17. 日志收缩造成数据库损坏情况下的恢复;
  18. 仅剩损坏的备份文件情况下的恢复。

SQL Server数据库恢复工具SQLRescue技术特点:

只要SQL Server数据库的数据文件存在,我们就有办法帮您从数据文件中找回重要数据。
  1. 从数据文件中直接恢复数据
  2. 不能附加时直接恢复数据并生成新的数据库
  3. 系统表损坏的数据库修复
  4. 快速修复SQL 823错误、连接中断错误

SQL Server数据库恢复工具SQLRescue支持的版本:

Microsoft SQL Server 7.0, 2000, 2005, 2008, 2008R2, 2012, 2014, 2016, 2017,2019。
+-------------------------------------华丽的分割线-------------------------------------------------------------------------