提供7*24专业Sybase数据库远程及现场技术支持,Sybase ASE及Sybase SQL Anywhere数据库修复服务,
请联系电话: (微信),QQ: 289965371!
We supply technical support for Sybase ASE and Sybase SQL Anywhere, also have many years of experience in recovering data from damanged Sybase devices.
Please contact us:
Phone:
Wechat: 13811580958
QQ: 289965371 联系我们获取数据库技术支持!
Email: 289965371@qq.com
扫描下方微信,联系我们:
扫描雨翰数据恢复官方微信获取专业数据库恢复服务

 

随着Sybase被完全整合到SAP下,Sybase原来的支持网站被SAP Support Portal取代。
只有购买了SAP服务的用户才能使用账号登录SAP Support Portal进行介质下载、补丁升级、报Incident等。
考虑到Sybase数据库的初学者或者没有购买原厂服务的Sybase客户情况,现提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息。
在SAP Support Portal网站或者google上搜索Targeted CR List for ASE,可以看到针对不同版本的CR(CR表示Change Request)简单描述信息列表。
需要注意的是:Targeted CR List for ASE列出的CR虽然绝大多数是BUG,但有一些是更改需求。
以下提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息!

如有问题,请联系我!

QQ :289965371 联系我们获取数据库技术支持!
Email:
不仅仅包括BUG的详细描述信息,还包括首次报告BUG的平台、数据库版本以及BUG修复历史过程;有些BUG还提供了Workaround来临时解决该BUG带来问题。

 

CR:223821
CR Number:   223821
Product Name:   PB Enterprise
Product Component:   Installation
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Webpb dlls and pbo7390.dll are in the pb 9.0 build as well as 8.0.

Please remove them from the build!!



The dlls that should be removed from PB 9.0 are:

pbcgi90.exe

pbisa90.dll

pbns190.dll

pbns290.dll

pbns390.dll

pbo7390.dll





The webpb dlls are included in the pb 8.0 beta 1 install.



From the Powerbuilder 7 release notes, version 7.0 will be the final release of

Powerbuilder which will incorporate Distributed Powerbuilder functionality.



Please remove the following dll's from the install:

pbcgi80.exe

pbisa80.dll

pbns180.dll

pbns280.dll

pbns380.dll



CR:223825
CR Number:   223825
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Filtering and sorting a member datawindow of a composite datawindow may caused blank space to appear where data sholuld be when displayed in an appliction
Workaround Description
 None.



CR:223826
CR Number:   223826
Product Name:   PB Enterprise
Product Component:   UO Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 3 09 Feb 2001 Fixed
Description
The following dpb references are still included in pb 8.0:

1. The transport object appears in the ddlb under
pb objects/standard class.
2. Transport object appears in the browser under the system tab

From the pb 7.0 release notes, version 8.0 will be the final release of
Powerbuilder which will incorporate Distributed Powerbuilder functionality.



CR:223828
CR Number:   223828
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Oct 2001 Fixed
Description
GetFileOpenName does not open the default folder when the Open Dialog comes up



CR:223858
CR Number:   223858
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10032 05 Jan 2001 Fixed
Description
Cannot enter some hebrew characters in an editmak column



CR:223865
CR Number:   223865
Product Name:   PB Enterprise
Product Component:   Help
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Sep 2000 Fixed
Description
When trying to open a workspace with a target who's PBLS no longer exist, you are prompted that the target will be deleted... The help button on that dialog doesn't do anything



CR:223873
CR Number:   223873
Product Name:   PB Enterprise
Product Component:   DW SaveAs
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Add a SaveAsXML option to datawindow



CR:223879
CR Number:   223879
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.1 1238 02 Jan 2001 Fixed
Description
6.5 EBF/7.0.2 8046 C3 Regression. The itemerror is being fired before Itemchanged on date columns that are left as 2000/00/00 for example. The firing order is ItemError, ItemChanged, ItemError. It should change the date to 2000/01/01 automatically and only fire the itemchanged event.



CR:223910
CR Number:   223910
Product Name:   PB Enterprise
Product Component:   DB Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Oct 2001 Not reproducible with latest version of the product available as of Resolution Date
Description
In the db Painter, create a view, if you set a compute field, it's impossible to set an alias for it. see closed CR 196018.
Workaround: use db tools like sql central
Workaround Description
 use db tools like sql central



CR:223926
CR Number:   223926
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Sep 2000 Duplicate
Description
Error messages in the output window are differentiated from other messages as the text is blue in color instead of black. When one highlights an error message the row selected color turns to Dark blue and the text to Red, which is unreadable.
It would be nice if either the text is turned to white or the selection color is lighter blue so that the message is readable.



CR:223959
CR Number:   223959
Product Name:   PB Enterprise
Product Component:   Function Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 2 25 Sep 2000 Fixed
Description
7.0 GPF creating a new function object. If you simply change the return type to "string" and select the [declare] item in the 1st dropdown listbox in the function header, you will get 'Discard Changes' response window. If you click on no button, you will get a GPF in MSVCRT.DLL.

This only happens in the function object painter.



CR:223961
CR Number:   223961
Product Name:   PB Enterprise
Product Component:   DataBase
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Oct 2000 Duplicate
Description
If client software for a database is not locally installed but is being used using a mapped drive, one is not able to register the native dll.
Workaround Description
 Add the entry manually into the registry.
Under HKEY_LOCAL_MACHINE\Software\Sybase\PowerBuilder\8.0\Vendors
Edit>New>String Value
SYC Data=Adaptive Server Enterprise
O84 Data= O84 Oracle 8.0.4



CR:223973
CR Number:   223973
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Sep 2000 Not a Bug
Description
The erroneous situation is when one treeview item is selected and then immediately a different item is RMB (RightMouseButton) clicked and a delete operation is performed. The actual item DELETED is the first one that had received focus rather than than the one chosen by the user.

In the treeview control RightClicked event, REPLACE il_tvitemhandle = handle WITH il_tvitemhandle = this.selectitem(handle) to get the actual handle of the specified item.
Workaround Description
 In tv_1 RightClicked event, REPLACE il_tvitemhandle = handle WITH il_tvitemhandle = this.selectitem(handle) to get the actual handle of the specified item.



CR:224004
CR Number:   224004
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.2 10002 11 Apr 2001 Fixed
Description
Works in 7.0.2 8003. Does not work in 7.0.2 8046 C3.
7.0.2 EBF Regression. OLE Database Blob column in a datawindow using Microsoft Word 8.0 does not work. Data is not saved to the datawindow blob column when the user clicks "Close and Return" from Word.
You also cannot close Word at this point and nothing is in the blob column to save to the database.



CR:224007
CR Number:   224007
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10007 05 Dec 2000 Fixed
Description
PB8 Beta1: (re)deployment of PB component sets thread.safe property to false.

Update from Development:
For pb7.0.3 and PB8 this flag has been exposed in the UI to the user. By default in pb7.0.3 standard components can have thread.safe=true and false... For Service and shared components thread.safe is set to false and cannot be modified by the user.

For pb8 there is a slight diff in behavior...
Standard comps... thread.safe=true/false
Shared comps... thread.safe=false
Service comps 1 instance(default) thread.safe=false
Service comps. more than one instance thread.safe=true/false



CR:224024
CR Number:   224024
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
This problem occurs for PB NATIVE connection to Oracle db using Oracle 8.0.5 client.
This incorrect mapping for Float datatype occurs when a dynamic datawindow object is created within the PB application using function :-
integer dwcontrol.Create ( string syntax {, string errorbuffer } )

PB error appears regardless of dbparm setting DisableBind = 0 or 1 ;



CR:224064
CR Number:   224064
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 3 36107 08 Jan 2001 Fixed
8.0 Beta 3 27 Feb 2001 Fixed
03 May 2001 Fixed
27 Mar 2001 Fixed
Description
PB8 Beta1: Cannot generate proxy for EJB
Problem specifically occurs because IDL for the RemoveException does not result in the creation of an Exception user object on the client side (as part of the proxy generation process).
Workaround Description
 Can be worked around (painfully ;>) by first separately generating IDL for the CTSComponents package and
then deleting everything but RemoveException, CreateException and FinderException. Then you can try to create the proxy for the EJB



CR:224075
CR Number:   224075
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.2 25 Sep 2000 Fixed
Description
7.0.2 EBF (9023) Regression. Doubleclicking on a user object function script in function tab of script painter causes GPF in MSVCRT.DLL.



CR:224087
CR Number:   224087
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Open
OS:   Solaris 2.6
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
When trying to print using the print() function on unix, nothing happens. No data is sent to the print queue.

The test case is creating a datastore and then associating a psr file. It then uses the print() powerscript function to print out the datastore.

Per PB Product Management, this is not a bug. This CR has been submitted as a New Feature Request/Enhancement Request:

The following information is from the PB 7.0.3 Maintenance Release "readme":

The PowerBuilder 7.0.3 version of the PowerBuilder VM must be available on the server.
The PowerBuilder VM includes PBVM70.DLL, PBJAG70.DLL, PBDWE70.DLL, and other
PowerBuilder files required at run time.

On UNIX, the shared libraries are called libpbvm70x.ext, libdwe70x.ext, and so forth, where
ext is the shared library extension for each UNIX platform. These runtime libraries do not
provide support for Windows API calls or graphical operations, including printing. If you deploy
a PowerBuilder component to an EAServer host running on UNIX, the component can have
neither graphical dependencies nor dependencies on the Windows application programming
interface.



CR:224105
CR Number:   224105
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10003 29 Jan 2001 Fixed
Description
Regression 7.02 build 9023: Datawindow with a compute field, filter condition dw_1.retrieve causes GPF



CR:224114
CR Number:   224114
Product Name:   PB Enterprise
Product Component:   Workspace and Targets
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Oct 2000 Not a Bug
Description
The File/Open dialog is too small for PBLs on paths that might have more than 48-50 characters.

Development: This dialog is resizable though it looks like it's a modal, non-resizable dialog.



CR:224139
CR Number:   224139
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Req: Functionality should be added to find open window of dos exe



CR:224186
CR Number:   224186
Product Name:   PB Enterprise
Product Component:   Winfree
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 Fixed
Description
When a large number of PowerBuilder client applications connect to the Jaguar server simultaneously an excessive amount of memory is consumed by the Jaguar server. 20 client applications in my test case. When the same number of instances are connected manually the memory usage is less than 50% i.e. one after the other.



CR:224189
CR Number:   224189
Product Name:   PB Enterprise
Product Component:   Workspace and Targets
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
27 Sep 2000 Duplicate
Description
Memory leak when successively opening and closing workspace. Running NT Task Manager and monitoring the Performance the memory usage continues to climb as you open and close different workspaces. Memory does not seem to be released until PB itself is closed down.



CR:224207
CR Number:   224207
Product Name:   PB Enterprise
Product Component:   DB Trace
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
This is a list of enhancement requests for the PB DB trace functionality:-
1. Disable dialog window when "TRACE" has been specified for the PB application.
2. In "pbtrace.log", specify DATE stamp when SQL is executed.
3. In "pbtrace.log", specify TIME stamp when SQL is executed.
4. Create new TRACE parameter to enable/ disable FETCH row data to be written in
log file.



CR:224211
CR Number:   224211
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10087 03 Sep 2001 Fixed
03 Sep 2001 Fixed
Description
With consolidated PBD and duplicate object names, the last object is put in the Jaguar deployed PBD, the opposite of what happens in a normal library search list with duplicate named objects (first object found is used).



CR:224221
CR Number:   224221
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
19 Sep 2000 Fixed
Description
Connecting to Your Database makes the following references to Unicode (which is no longer supported in PB7):

1. Page 90 - Unicode reference and references to PBO8470U.DLL, PBO7370U.DLL and PBOR870U.DLL should be deleted.

2. Page 96 - #5 Titled "Powerbuilder for Unicode Only" should be deleted.

3. Page 110 - Reference to Unicode and PBSYBC70U.DLL (not shipped with product) should be deleted in chart



CR:224222
CR Number:   224222
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Generation of proxy for PB service component produces incomplete proxy
'Build' the proxy, you can place the proxy object in the same PBL, and you'll get the following error in the build process:
Warning: A full or incremental rebuild should be performed.
The following object(s) may not be usable in their present state.
n_srvtest
Rebuild the application, you'll then get a more meaningful error
Object: n_srvtest
n_srvtest Class Declaration
(0001): Error C0001: Illegal data type: genericservice
Workaround Description
 Build the proxies for the IDL package CTSServices BEFORE generating the proxy it will succeed.



CR:224249
CR Number:   224249
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
Using PB 7.0.2 build 9023 with a datawindow with column and an editmask. If the column is highlighted, and the delete key is pressed the EditChanged event is not firing. Fails for numeric, string, and date editmasks. Works in PB 6.5.1 (build 1219). If the editmask is removed the event fires. Fails the same way in 8.0.3 as well.



CR:224253
CR Number:   224253
Product Name:   PB Enterprise
Product Component:   Environment Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
27 Sep 2000 Fixed
Description
Simple objects automatically appear in system tree
after they are created, but those created via wizards do not appear in system
tree. You need to do a refresh to see them in system tree.



CR:224256
CR Number:   224256
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Apr 2001 Fixed
Description
When chosing DataWindow Update stored procedure ";0" is added after the name of the stored proc - as in "EXECUTE REMOTE PROCEDURE: SYSTEM.DEL_DEPT;0".
This causes error ORA-06550 PLS-00103 on execute:
ORA-06550: line 1, column 31: PLS-00103: Encountered the symbol "0" when expecting one of the following...
Workaround: Export DataWindow, modify syntax and reimport
Workaround Description
 export DW and modify syntax and reimport



CR:224257
CR Number:   224257
Product Name:   PB Enterprise
Product Component:   Environment Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 2 29 Sep 2000 Fixed
Description
cannot edit source for a proxy object



CR:224264
CR Number:   224264
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
This is an enhancement request.
When one or more group breaks are defined for a Grid, Tabular etc. datawindow, the <UpArrow> & <DownArrow> keys perform a scroll by PAGE mechanism rather than scroll by row.

Note: This is different behaviour to e.g.
-Grid or tabular datawindow (with NO group breaks), performs scroll by row.



CR:224266
CR Number:   224266
Product Name:   PB Enterprise
Product Component:   Web Wizards
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
01 Nov 2000 Fixed
Description
PB8 Beta1: Crashing when editing a web page, selecting Color/Fonts from Options.



CR:224283
CR Number:   224283
Product Name:   PB Enterprise
Product Component:   DB Informix
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
This is an enhancement request.
Would like to have an estimation of the SQL statement for an Informix db command "SET TRIGGERS ..."
E.g. SET TRIGGERS upd_cust ENABLED;
In PB7 ISQL session, "Explain SQL" gives a PB msg "No plan was returned by database interface" if there are no execution plans or if support is not there for the sql syntax;



CR:224290
CR Number:   224290
Product Name:   PB Enterprise
Product Component:   UO Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
3019 02 Jan 2001 Fixed
Description
If you implement the getPin function in SSLCallback and then generate proxies for CTSSecurity, it generates Informational C0146: warning messages that 'sessioninfo' conflicts with a global variable of the same name. For getPin sessionInfo is an argument name, for CTSSecurity it is a proxy object.



CR:224292
CR Number:   224292
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
Selection of row using a downarrow in a dddw does not work is row retrieved is one.
The behavior of not being able to select only happens if one uses GetFullState/SetFullState

when setting data in a datawindow control via a datastore. If I assign the dataobject to the

control at runtime and do a insertrow, then try tabbing into the nested dw's and using the

arrow keys it works fine.

Workaround :
Set an initial value for the dddw so that it gets populated automatically.
Workaround Description
 Set an initial value for the dddw so that it gets populated automatically.



CR:224297
CR Number:   224297
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
03 Apr 2002 Not a Bug
Description
After a new row is inserted and a column is populated with
setitem, the row status is NewModified and the column status is DataModified.
Changing the column status to NotModified using setitemstatus does not
appear to work.

According to the documentation, changing a column status is simple.
Workaround Description
 Workaround is to set the column status to DATAMODIFIED! first, then set the status to NOTMODIFIED!



CR:224307
CR Number:   224307
Product Name:   PB Enterprise
Product Component:   UO Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 GA 06 Apr 2001 Fixed
Description
An EAServer Proxy for CTSSecurity package will generate
*Exception objects. Open any one of those objects will crash PB.
From the crash handler, the following is generated:

Exception code: C0000005 ACCESS_VIOLATION
File Name: E:\pb80\PBUDO80.dll
File Version: 8.0.00.1313
Fault address=1275BFE0 Section:Offset=01:0005AFE0

Registers:
EAX:00000000
EBX:80020002
ECX:00000091
EDX:00000000
ESI:000040F8
EDI:02E83CC8
CS:EIP:001B:1275BFE0
SS:ESP:0023:0012D868 EBP:80020002
DS:0023 ES:0023 FS:0038 GS:0000
Flags:00010246

Call stack:
Address Frame Param0 Param1 Param2 Param3 Function Name
1275BFE0 80020002 00000000 00000000 00000000 00000000 PBWS_DlgCLDebugProc+1F10

OS version:
Windows NT 4.0, Build Number: 1381, Service Pack 5

Memory Status:
Total physical memory: 196024K
Available physical memory: 113084K
Total virtual memory usage: 146620K / 410744K
PowerBuilder virtual memory usage: 103156K / 2097024K



CR:224312
CR Number:   224312
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
When you want to add a PBL to an open target, allow the PBL to be dragged from the library painter and dropped into the workspace, and automatically update the library path



CR:224314
CR Number:   224314
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 3 30 Nov 2000 Fixed
Description
When saving script when the "Ignore compilation warnings
and lose changes" appears, if you hit yes, the changes are saved anyway.



CR:224346
CR Number:   224346
Product Name:   PB Enterprise
Product Component:   DW Expression
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
ENHANCEMENT REQUEST
======================

Add the possibility to use the Windows regional settings format instead of the US notation in numeric datawindow expressions.
If "comma" is specified as decimal separator, then numeric expressions accept european format ( eg 12,34.)
If "period" is specified, it accepts US format (eg 12.34)



CR:224369
CR Number:   224369
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
08 Mar 2001 Presently Not Targeted For Any Future Release Of This Product
Description
PB 8.0 beta 1 crashes when clicking to change a workspace and/or target in system tree, non-reproducible but crash handler output is attached from three separate crashes.



CR:224406
CR Number:   224406
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
When ActiveX control calls form "Modelessly" get message: "Runtime Error: 406" "Non-modal forms cannot be displayed in this host application from an ActiveX DLL, ActiveX Control, or Property Page." Similar to CR: 198123 but with a different error message

Workaround:
Use Modal Form
Workaround Description
 use modal form.



CR:224414
CR Number:   224414
Product Name:   PB Enterprise
Product Component:   Environment Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
System tree behavior not in line with Windows Explorer.
For example, if you right mouse click in the white space you see "Set Root", etc.
In windows explorer, an item gets highlighted and a popup menu appears
for the associated highlighted item.



CR:224462
CR Number:   224462
Product Name:   PB Enterprise
Product Component:   DB Informix
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 15 Jun 2004 EOL'd version. Not to be Fixed.
Description
7.0 Regression. Informix native driver PBIN7070.DLL. Select into using a decimal indicator (host) variable in powerscript truncates the output to an integer value.

select 42.19 / 2.42 from department;

Works correctly in the DBA administrator (datawindow) and returns 17.43388429752066 in PBIN7070.DLL and ODBC but this doesn't work in embedded SQL with:

decimal deci
select 42.19 / 2.42 into :deci from department;

will truncate "deci" at "17" (an integer)

Workaround: Use double datatype.



CR:224463
CR Number:   224463
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
If a TableCriteria is specified in the dbparm parameter for an O84 connection
then no tables are displayed in the database painter for the connection.



CR:224464
CR Number:   224464
Product Name:   PB Enterprise
Product Component:   Workspace and Targets
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Nov 2000 Fixed
Description
When a HTML page of type "Frameset Page" is created and when you try and preview the HTML page the frames in the preview tab are not visible until you click on another tab and click back onto the preview tab.



CR:224466
CR Number:   224466
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Nov 2000 Fixed
Description
6.5 EBF /7.0.2 C3 Regression. Editmask of type date no longer autocompletes days when you type a "3" in the first position. In the past, if the day was "19" and you typed a "3" over the "1", the datawindow automatically changed "9" to "0" so with typing one character, it changed "19" to "30".

This behavior no longer happens in 7.0.2 C3.
6.5 builds > 1220 have this behavior.



CR:224470
CR Number:   224470
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Sep 2000 Not a Bug
Description
PB8 Beta1: GUI covers arguments when fn prototype has more args than last fcn
From development: Not a bug, use scroll bar.



CR:224489
CR Number:   224489
Product Name:   PB Enterprise
Product Component:   Project Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Apr 2005 Presently Not Targeted For Any Future Release Of This Product
Description
If you build an application project for which the directory structure is no longer valid (e.g., you move from one machine to another), the library list is updated on the fly, but all the checkboxes in the PBD/DLL column are cleared.
Review Status
 04/25/2005:

This CR was reviewed and closed as part of the Quarterly CR Review process. It is "Not targeted for any future release".



CR:224503
CR Number:   224503
Product Name:   PB Enterprise
Product Component:   Project Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Jul 2004 Not a Bug
Description
PB8 Beta1: Some errors on building a project show up in error window, some in modal dialog boxes, would like this to be consistent, preferably all in the Error dialog (to allow unattended install, for instance.)



CR:224513
CR Number:   224513
Product Name:   PB Enterprise
Product Component:   DW Graph
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10030 18 Dec 2000 Fixed
Description
SetSeriesStyle() is called for a to connect datapoints with a continuous line. In PB 6.5 and 7.0 GA this works as expected connecting datapoints from left to right. In current builds on PB 6.5.1( build 1219), 7.0.2 (9025) and {PB 8.0 beta the lines connecting the datapoints are not correct but are appear to be connecting in the order of the data not right to left.



CR:224558
CR Number:   224558
Product Name:   PB Enterprise
Product Component:   DB Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10009 21 Nov 2000 Fixed
Description
REGRESSION PB 7.x
Trying to view the SQL statement of a DW fires a GPF if :
- Oracle Database is used (7 or 8) and the SQL statement contains :
1 Alias at least
AND 2 tables at least
AND a where Clause.

Ex : SELECT TONE_ID AS alias1,TTWO_ID AS alias2
FROM TABLE_ONE,TABLE_TWO
WHERE TONE_ID = '12345'



CR:224561
CR Number:   224561
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Grid DW - headers are defined 3D but the 3D effect is lost



CR:224564
CR Number:   224564
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
06 Nov 2007 Fixed
Description
Make access to library list item on context menu of target or toolbar, it was an adventure trying to find where it is.
The only way to get to it is - RMB on target - go to properties and it is the very first tab.



CR:224565
CR Number:   224565
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Aug 2004 Not a Bug
Description
1) Suggestion here is to separate the Progress info from the Error info (Make them a tabbed pane or something). With larger applications, it becomes increasingly difficult to locate errors (without using the Next/Prev error options).

2) add a RMB option to "go to" the object causing the error. Edit and Edit course are great, but just being able to go to the object in question would be real helpful as well.



CR:224566
CR Number:   224566
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
07 Dec 2000 Fixed
Description
when trying to add an exception to a function that overrides another function that does NOT throw that exception there is no clear message that this is not permitted

For this particular example, this is not the crux of the problem; however, the GUI could handle it much nicer. I believe that adding an exception that is not defined on the 'ancestor' function should get the same type of error as trying to override a function and changing only the return value. The compiler catches the later case and probably should catch the similar case with exceptions.



CR:224567
CR Number:   224567
Product Name:   PB Enterprise
Product Component:   Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 RC 04 Oct 2001 Fixed
Description
A numeric editmask control is on a window. When the data value is highlighted and deleted and then the user tabs to another control the Modified Event fires. But if the user highlights the data, deletes it and then while re-entering the data backspaces and then enters the data then the Modified event does not fire. Also if instead of deleting the data the user backspaces over a digit and then enters the new data and tabs out the Modified Event does not fire even if originally the user had highlighted and deleted the data.

This is not a problem with PB 7.0.2.



CR:224568
CR Number:   224568
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
When a spin control edit mask, either on a datawindow or as a control, is slightly smaller than the size required to hold the entire datetime column and it has a justification of either Right or Center is clicked it initially blanks out and when clicked again results in an Application Error with the following message.

The exception unknown software exception (0xc00000fd) occured in the application at location 0x1134d95c.

Customer reported this as a regression but further testing revealed that the problem was in previous builds of 7.0 but that a recently fixed CR 216105 changed the size of the actual arrows which resulted in this customers editmask being too small. Other spin controls with other data types did not seem to have the problem.

Also when run in PB 8.0 beta the application error did not occur although the edit mask was unusable as it simply blanked out.

Simple workaround is to simply increase the size of the control.

Refer to CR 216105 for an explanation of that fix.



CR:224571
CR Number:   224571
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
3025 27 Nov 2000 Fixed
Description
SSLCallback and SSLServiceProvider functions do not throw exceptions but should to enable appropriate behavior with EAServer

The SSLCallback object was created to allow SSL connections to EAServer. The functions provided on this object are getPin, getCertificateLabel, getCredentialAttribute, and trustVerify. The first three of these functions are supposed to throw a userabortedexception to cancel the SSL request; however, since the PB SSLCallback object functions do not have these exceptions defined on them, it is impossible (by design) in the painters to override the function to add a throws clause. Because of that it is impossible to cancel an SSL request once it has begun.

The other methods on the PB SSLCallback and SSLServiceProvider object also do not throw exceptions and so would need to be investigated as well.
Workaround Description
 add the appropriate THROWS clause to the getPin method of the SSLCallBack object (this had to be done by exporting the source of n_sslconnect).



CR:224640
CR Number:   224640
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
In PowerBuilder 7 the retrieve of a datawindow with two retrieval arguments in an UNION

can give the following error:



Select error: ORA-1790: expression must have same datatype as corresponding expression



Work-around is to enclose the retrieval arguments in an expression, e.g. to_number function.
Workaround Description
 XYIN 08-Oct-00
PB7.0.3 build 10002, Oracle 84 native driver,Ora8.
I've tried using syntax mode to create the dw, the sql is as below,
select :test1 col1 from customer union select :test2 col2 from customer;
no error occurred



CR:224649
CR Number:   224649
Product Name:   PB Enterprise
Product Component:   Menus - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
cr 146942 which is an enhancement request for only part of the problem described above



CR:224675
CR Number:   224675
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10048 25 Feb 2004 EOL'd version. Not to be Fixed.
Description
PB7.x - N-up datawindow - item focus not consistent - sometimes a different item in the same row as the item clicked on gets focus. Verified fixed in 7.0.3 build 10048.



CR:224712
CR Number:   224712
Product Name:   PB Enterprise
Product Component:   DB Sybase System
Status:   Closed
OS:   Solaris 2.6
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Apr 2002 Presently Not Targeted For Any Future Release Of This Product
Description
PB Solaris 6.5 - Disconnect from ASE crashes PB and gives fatal error when using Open Client 11.x ebf 9065- replacing libtli_r.so with older version of Open Client resolves problem.
Workaround Description
 Replace $SYBASE/lib/libtli_r.so with older version of file.



CR:224713
CR Number:   224713
Product Name:   PB Enterprise
Product Component:   DW Plugin
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Mar 2004 EOL'd version. Not to be Fixed.
Description
Sort/Filter dialog not accessable in datawindow plugin. They should be accessable from the right mouse and datawindow buttons.



CR:224714
CR Number:   224714
Product Name:   PB Enterprise
Product Component:   SQL Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10003 09 Oct 2000 Fixed
Description
7.0 Regression. GPF in PBVM70.DLL selecting/pasting multiple stored procedures as RPCs from the "Remote Stored Procedure" dialog into a user object of type transaction in the "Declare Local External Functions" section in the user object painter.

Works fine if you paste ONE at a time.



CR:224716
CR Number:   224716
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enh Req PB8: Paste Special > Object enable for all painters



CR:224731
CR Number:   224731
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows 98
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.3 09 Jul 2004 Not reproducible with latest version of the product available as of Resolution Date
Description
During a long running task in PB, such as migrating
the PB Examples, and you alt-tab to another process such as the Netscape
browser and then alt-tab back to PB, you will see the Migration Application
window, then Netscape. The PB IDE is no where to be found when
using alt-tab. It stays in the background.



CR:224743
CR Number:   224743
Product Name:   PB Enterprise
Product Component:   MTS Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6003 25 Feb 2004 Fixed
Description
Passing a resultset from a MTS component to a
ADOResultSet seems to convert the date to 10/03/1818
and they are all the same date.



CR:224745
CR Number:   224745
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
In a N-up dw if a column's (say col 1) visible property is a expression based on a second column (say col 2) then the tab order set on the col 1 does work , in some cases even if the col is invisble one can tab into it and sometimes when the col is visible you cannot tab into it.



CR:224785
CR Number:   224785
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Mar 2004 EOL'd version. Not to be Fixed.
Description
HTML DW output skewed in IE 5 when the RIGHTMOST column is RIGHT justified and CSS (Generate Cascading Style Sheets) ON. The last column, rather than being WYSIWYG, goes to the far right of the browser screen. This does not happen in Netscape 4.5.



CR:224790
CR Number:   224790
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.1 1234 18 Oct 2000 Fixed
Description
Datawindow.syntax.data does not retrieve complete data

The lenght of data being retrieved into a string in PB 5 and 6 is about 196K where as the dw
has data of about 248K+. The complete data does get retrieved into the string variable in PB 7 or later. I have tried the retrieve into a blob but it is the same thing, I think it is the retrieve itself that is not working.
Workaround Description
 Ct. can use Datawindow.Data but he does not want to because the result is formatted which he does not want.



CR:224793
CR Number:   224793
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Since the connection object will now be of use only in targeting EAServer (no longer DPB servers), a couple of suggestions:

1) make the driver property optional
2) update errcodes to be more EAServer friendly - usually all we get is a 50 or 57 which isn't too descriptive
3) let the trace property specify a file that the IIOP client trace will get written to... the existence of this property would trigger PB to automatically set ORBLogIIOP and ORBLogFile when initializing the ORB



CR:224794
CR Number:   224794
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
There are a number of settings that can be made in the options property of the connection object to initialize the client-side C++ ORB (e.g., ORBSocketReuseLimit, ORBProxyHost, ...), in this way these properties are very much like DBParms for database connections.

The EAServer connection dialog could be extended to include these ORB initialization properties so that the options string would be built automatically when picking an EAServer connection in the connection object wizard. With a Preview tab, like on the database connection, customers would also be able to paste complete EAServer connection code directly into their application.



CR:224802
CR Number:   224802
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
12 Dec 2002 Presently Not Targeted For Any Future Release Of This Product
Description
When a new user object is created, the user object cannot be saved if PFC and any SCC API provider is used.
Workaround Description
 Workaround: If you remove the following PBLs from the library list you will be able to save your User Object:

pfcapsrv.pbl;
pfcdwsrv.pbl;
pfcmain.pbl;
pfcutil.pbl;
pfcwnsrv.pbl;



CR:224808
CR Number:   224808
Product Name:   PB Enterprise
Product Component:   Edit Mask
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
10066 25 Feb 2004 Fixed
Description
PB 7.02 Regression: PB crashes when copying text into a datefield on datawindow that has a edit-mask of mm/dd/yyyy defined on it



CR:224813
CR Number:   224813
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10087 19 Jun 2001 Fixed
Description
Deploying a PB jag component with create() function, fails to create IDL for the function.

It's apparently colliding with some reserved word in PB or Jaguar, and it fails to create the correct IDL. This is a problem for the Web Datawindow component that is shipped with Jaguar, in that this PB component does have a function named create() and it does have the correct IDL. So if a developer makes any changes to the Web DW component (a likely senario) and then redeploy's it, the create() function is no longer in the IDL.
Workaround Description
 The create function really is in the PBD. So manually edit the IDL and add create, then generate proxies.
You'll need to do this everytime you deploy, but once you have a good proxy you don't have to re-create it unless the interface has changed.



CR:224850
CR Number:   224850
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.1 1244 11 Dec 2000 Fixed
Description
Regression in PB6.5 after Build 482 and PB7
Calling a MS SQLServer 6.5 or 7 Stored procedure with a large text datatype argument
in embedded sql causes a GPF.



CR:224860
CR Number:   224860
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
08 Mar 2001 Fixed
Description
Opening 6 datawindows in PB 8.0 appears to be using up all the system resources when on a Win 95 platform. In NT 4.0 I was able to open 16 dw's before I seemed to have a resource problem and PB simply closed down. At this point I had to reboot my machine as when I reopened PB the datawindows were opening and closing in the order I had opened them previously.

In my case, after successfully opening 6 dws, the following warning popped - up from the resource monitor:

"Low Resources: Ninety percent or more of your system resources are in use. To free up system resources, quit any programs that you are not using. If you do not, your computer may stop responding".

This can be confirmed after clicking "OK" to the above warning and checking the resource meter. If you now try to open yet another dw, crash handler message comes up and PB crashes.

Additional Observations
==================

Closing the datawindows doesn't seem to return all of the resources, but closing PB8 and restarting it does - I closed dws one by one and saw resources recoup ( all the three - System\User\GDI)



CR:224882
CR Number:   224882
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Feb 2001 Fixed
Description
PFC Resize doesn't work correctly on sheets opened with Layered!



CR:224906
CR Number:   224906
Product Name:   PB Enterprise
Product Component:   WT - Editor - Script
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Apr 2001 Not reproducible with latest version of the product available as of Resolution Date
Description
Copy/Paste does not work in the script editor when using Context Menu
Workaround Description
 Use CtrlC/CtrlV shorcut instead of using the Popup menu



CR:224915
CR Number:   224915
Product Name:   PB Enterprise
Product Component:   Generators
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
03 Oct 2001 Fixed
Description
Unable to compile COM object having a function with more than 31 arguments



CR:225009
CR Number:   225009
Product Name:   PB Enterprise
Product Component:   Edit Mask
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.1 1270 02 Oct 2001 Not reproducible with latest version of the product available as of Resolution Date
Description
Editmask control on a window with change to alignment property (Alignment = Left!) in the getfocus() event. Does not matter what the alignment is changed to as any change to the alignment in this event causes a gpf when on WIN 95/98 in user.exe. When the same code is place in other events the problem also does not occur.

This happens only when one clicks on editmask control, if you tabs to the control and then enter data eveything works fine.

Problem does not occur on Win NT 4.0 but only on Win95/98.



CR:225012
CR Number:   225012
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Dec 2000 Fixed
Description
Regression: Nested report does not display in n-up presentation style.
Verified fixed in 7.0.3 build 10030



CR:225056
CR Number:   225056
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Check-out does not fail when archive and object in public library are different as stated on page 141 of
PowerBuilder 7.0 User's Guide



CR:225059
CR Number:   225059
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
19 Sep 2001 Not a Bug
Description
WIndow painter perfomance problem in 7.0.2 vs. 6.5.1 when opening a window with lots of controls.
Workaround Description
 Try to reduce the number of controls by using datawindows instead.



CR:225113
CR Number:   225113
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows 2000
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Mar 2004 Not a Bug
Description
Windows 2000. The library painter (set to Default Layout) comes up slowly - hangs - (30-45 seconds) if mapped drives exist that are no longer accessable (machine turned off, network down). Windows 2000 clearly shows the mapped drives in the library painter and a red 'X' through the ones it can't reach - though again you wait 30-45 seconds. NT 4.0 does not have this performance problem. NT 4.0 also displays ALL drives (whether accessable or not) WITHOUT the red "X" through the mapped drive definition.



Using the 'File, Select Library, Browse' also has the 'hang' issue.



From PB Engineering: This is not a PB bug. If I bring up winfile and one of my drives is inaccessable, it takes a lot more time than if all the drives are accessable just as PB does. Also Win NT does not mark inaccessable drives with an X so PB is doing just what NT does.



CR:225125
CR Number:   225125
Product Name:   PB Enterprise
Product Component:   DW Graph
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Graph datawindow category text is truncated when font.escapement is changed in script to 600 (60 degrees). 900 (90 degrees) and 450 (45 degrees ) seem to work properly.



CR:225128
CR Number:   225128
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   Solaris 2.6
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
20 Feb 2001 Fixed
Description
Solaris version of libpbo8470x.so driver fails with Oracle 8.1.6 client software.
It tries to load Oracle libclntsh.1.0 dll which no longer exists in 8.1.6.
Verified fixed in build 10030 of PBVM on solaris.
Workaround Description
 Create a symbolic link called libclntsh.so.1.0 pointing to the 8.1.6 library.



CR:225189
CR Number:   225189
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   Solaris 2.6
Original Version:   6.5.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Using oracle 8.1.6 client software on solaris 2.6 and pb 6.5.1,
the following error message appears when trying to connect to a 8.1.6 server
using the o84 driver:

DBMS o84 orcle 8.0.4 is not supported in your current installation

When trying to connect to a o73 server with oracle 8.1.6 client, a message
appears that it cannot load the libpbo8460.so.

Works ok using the oracle 8.1.5 client software and the workaround listed
in tech doc 1002125. The workaround for 8.1.5 client is

ln -s libclntsh.so.8.0 libclntsh.so.1.0



CR:225252
CR Number:   225252
Product Name:   PB Enterprise
Product Component:   Target Wizards
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request Sent to Development:

"Is there anyway you can add a Java target to the PB8 environment? I'm
not talking about including PowerJ as part fo the IDE, but more like the
file painter with a compile and possibly a deploy to EAS capability."

But for the purposes of PowerBuilder and the Powersite functionality now included, it's reasonable to include a mechanism to generate and compile Java stubs from EAServer components. Currently in order to build a Dynamo page accessing EAServer, you have to access Jaguar Manager to first generate the stubs and then a separate DOS window to compile the stubs. EAServer 4.0 is supposed to have a wizard approach to doing this and at some point there will be a command line interface to EAServer to accomplish this (3.6.1 timeframe?). If at all possible this should be considered for GA .



CR:225259
CR Number:   225259
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Cannot insert a static text field in a datawindow design with certain view setup (preview and design as two overlapping views). As you type in the text to the text object, it only accepts the last character typed.



CR:225268
CR Number:   225268
Product Name:   PB Enterprise
Product Component:   MAPI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Using Microsoft Outlook Express the mailsend fails
when using mailrecipienttype = mailoriginator! Works ok when using
mailrecipienttype = mailcc!

According to microsoft knowledge base article q25317 - Getting MAPI read
receipt functionality over the Internet Mail Service, Outlook Express uses a different
mail message property for read receipts and simply ignores the property used by
Outlook MAPI client. Outlook Express uses this property for read receipt requests:
Disposition-Notification-To:

Outlook uses this property for read receipt requests:
Return-Receipt-To:

If this is the case, than Powerbuilder should accommodate Outlook Express.



CR:225279
CR Number:   225279
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Jan 2001 Fixed
Description
PB8 Beta1: Datawindow contains a computed column. The computed column is also one of the two columns in the sort criteria. When the computed column is deleted, immediately, a datawindow error "Expression is not valid" pops up. Click "OK" - another error "Sort or GroupSort is invalid. Datawindow has been saved without the sort expression." pops up. The computed column now disappears.

If you go to 'Rows - Sort' - the computed column is still there under 'columns' and remains checked for 'Ascending'. I think it shouldn't even be there. If you uncheck it - same sequence of errors.
However, if you drag the computed column into 'Source Data', it successfully disappears and you're back in business.( a workaround)



CR:225338
CR Number:   225338
Product Name:   PB Enterprise
Product Component:   DW SaveAs
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enable SaveAs( ) to .xls and .dbf to save more than 255 chars per cell
Workaround Description
 First, save the DW to HTML file (TEXT file also OK), then convert the file to
the Excel BIFF8 file using the MS Excel's automation function.



CR:225343
CR Number:   225343
Product Name:   PB Enterprise
Product Component:   DW ActiveX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Criteria specified by the user are NOT added to the SELECT statement
Workaround Description
 Use a DataWindow Transaction Object to connect the datawindow activex.



CR:225349
CR Number:   225349
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 May 2001 Fixed
04 Jan 2001 Fixed
Description
7.0 Regression. If you attempt to change group band properties such as "Group", "New Page on Group Break" or "Reset Page on Group Break", when you exit the painter, PB/IM does not prompt to save changes.



CR:225360
CR Number:   225360
Product Name:   PB Enterprise
Product Component:   Workspace and Targets
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   8.0 Beta 1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request

With everything going the way it is, (JSP's J2EE etc), would it be
possible to add a Java Class as a web target? What I found is that I can
use the PB8 file editor to edit my java classes easily enough, which
allows me to use such features as indenting, block commenting, etc. Nice
features in the PB editors. When I create a Script file in a web target,
and I import my java code, it color codes some of the java stuff for me
(recognizing enough from the javascript capabilities it has no doubt).
But this editor does not have the block indenting/commenting
capabilities of the PB script painters (not needed for javascript etc).
Also, if I save this file with a Java extension, it appears in the
treeview under my web target, which is great, but if you then
double-click on it to open it, it tries to open Wordpad, my default
.java association, instead of using the script painter inside of PB.

I know it sounds more and more like PowerJ integration, but I leave
PowerJ to do things like EJB's which it is well suited for. For simpler
stuff, I would ordinarily use Wordpad or the PB File Editor. Now that
I've seen the javascript script painter in there, it seems like it would
not be too much to allow .java files to be included in that list.
Workaround Description
 N/A - Enhancement Request



CR:225390
CR Number:   225390
Product Name:   PB Enterprise
Product Component:   DB ODBC
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10007 02 Nov 2000 Fixed
Description
PBODB70 ODBC error during connection may not be detected. Builds 10002 - 10006 only.





--------------------------------------华丽的分割线-------------------------------------------------------------------------

Sybase SQL Anywhere数据库恢复工具ReadASADB:

之前就已经研发成功了能够从Sybase SQL Anywhere的DB文件中恢复数据的工具: ReadASADB。
此工具支持ASA v5.0, v6.0, v7.0, v8.0, v9.0, v10.0, v11.0, v12.0, v16.0, v17.0等版本。
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具。
恢复Sybase SQL Anywhere的工具在国内处于领先水平。

Sybase SQL Anywhere数据库恢复工具ReadASADB功能
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具
  1. 适用于所有的SQL Anywhere版本    包括:5.x,6.x,7.x,8.x,9.x,10.x,11.x,12.x,16.x,17.x
  2. 适用于所有的UltraLite版本
  3. 能够恢复出来表结构和数据
  4. 能够恢复自定义数据类型
  5. 能够恢复存储过程等对象的语法
  6. 能够导出到目标数据库
  7. 能够导出到SQL文件并生成导入脚本
  8. 支持多种字符集,包括:cp850、cp936、gb18030、utf8等
  9. 能够恢复未加密或者简单加密类型的数据
  10. 简单易用
  11. 限制:不支持AES加密的数据文件
请参考:研发成功了从Sybase SQL Anywhere的DB文件上恢复数据的工具
            SQL Anywhere数据库非常规恢复工具ReadASADB使用介绍

Sybase SQL Anywhere数据库恢复工具ReadASADB适用场景

各种误操作:

  1. 误截断表(truncate table)
  2. 误删除表(drop table)
  3. 错误的where条件误删数据
  4. 误删除db或log文件
  5. 误删除表中的字段

Sybase SQL Anywhere数据库恢复工具ReadASADB的应用场景:

1.因为物理磁盘故障、操作系统、系统软件方面或者掉电等等原因导致的Sybase SQL Anywhere数据库无法打开的情况;
2.误操作,包括truncate table,drop table,不正确的where条件导致的误删除等;
Sybase SQL Anywhere无法打开时,比较常见的错误是:Assertion failed。
如:
1、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Checkpoint log: invalid bitmap page -- transaction rolled back
2、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Page number on page does not match page requested -- transaction rolled back
3、Internal database error *** ERROR *** Assertion failed:200502 (9.0.2.2451) Checksum failure on page 23 -- transaction rolled back
4、File is shorter than expected
5、Internal database error *** ERROR *** Assertion failed: 201116 Invalid free list index page found while processing checkpoint log -- transaction rolled back
6、*** ERROR *** Assertion failed: 51901 Page for requested record not a table page or record not present on page
7、*** ERROR *** Assertion failed: 201417 (7.0.4.3541) Invalid count or free space offset detected on a table page
8、Internal database error *** ERROR *** Assertion failed: 201425 (8.0.3.5594) Invalid count or free space offset detected on a free list page -- transaction rolled back.
9、Internal database error *** ERROR *** Assertion failed: 100702 (8.0.1.2600) Unable to modify indexes for a row referenced in rollback log -- transaction rolled back


-------------------------------------------------------------------------------------------

Sybase ASE数据库恢复工具READSYBDEVICE:

一个不依赖数据库管理系统、直接从Sybase数据库设备文件上提取数据的业内领先的恢复工具!
能够从损坏的Sybase ASE设备文件(.dat)上提取数据的非常规恢复工具。

Sybase ASE数据库恢复工具READSYBDEVICE的主要功能:

  1. 被勒索病毒加密数据文件及备份文件情况下的恢复;
  2. 系统崩溃只剩下数据文件的情况下的恢复,甚至数据库文件不存在而只有损坏的备份文件情况下的恢复;
  3. 因断电、硬盘坏道等造成数据库文件损坏情况下的恢复;
  4. delete数据恢复、误update数据恢复、误删除表(drop)恢复、误truncate表恢复 等;
  5. 各种Sybase内部系统表损坏、索引错误的修复;
  6. master数据库损坏而无法正常运行情况下的恢复;
  7. Sybase数据库被标记为可疑,不可用等情况的恢复;
  8. Sybase数据库中数据文件内部出现坏块情况下的恢复;
  9. Sybase数据库无数据文件但有日志文件的情况下的恢复;
  10. Sybase数据库只有数据文件无任何日志文件的情况下的恢复;
  11. Sybase数据文件被误删除情况下的碎片提取恢复;
  12. 磁盘阵列上的Sybase数据库被误格式化情况下的数据库恢复;
  13. 数据库sysobjects等系统表损坏无法正常应用情况下的恢复;
  14. Sybase数据库还原数据库出现失败情况下的恢复;
  15. Sybase数据库只剩下损坏的备份文件情况下的恢复。

Sybase ASE数据库恢复工具READSYBDEVICE支持的版本:

Sybase ASE 11.0.x,11.5.x,11.9.x,12.0.x,12.5.x,15.0.x,15.5.x,15.7.x,16.0.x


-------------------------------------------------------------------------------------------

SQL Server数据库恢复工具SQLRescue:

一个不依赖数据库管理系统、直接从SQL Server数据库文件上提取数据的业内领先的恢复工具!
能够从损坏的SQL Server数据库文件(.mdf)上提取数据的非常规恢复工具。

SQL Server数据库恢复工具SQLRescue的主要功能:

  1. 系统崩溃只剩下数据文件的情况下的恢复,即无日志文件或者日志文件损坏情况下的恢复;
  2. 断电导致数据库文件损坏情况下的恢复;
  3. 硬盘坏道造成数据库损坏情况下的恢复;
  4. 数据文件内部存在坏页情况下的恢复;
  5. 企业管理器误删除数据表记录,管理软件误删除数据表记录的恢复;
  6. 并闩锁错误、格式化、误删除后导致软件不能使用的情况;
  7. 无法读取并闩锁页sysindexes失败情况下的修复;
  8. 数据文件被误删除情况下的碎片提取恢复;
  9. 系统表损坏、索引错误、误删除数据库表、删除记录的数据找回;
  10. master数据库损坏而无法正常运行情况下的恢复;
  11. 数据文件无法附加情况下的数据恢复;
  12. 数据库被标记为可疑,质疑,不可用等情况的恢复;
  13. 数据库sysobjects等系统表损坏情况下的恢复;
  14. 数据被误(drop、delete、truncate)删除表数据的恢复,误update后的数据恢复等;
  15. 还原时报一致性错误,错误823等情况下的数据恢复,各种错误提示的数据库文件修复;
  16. 数据库被误格式化等情况下的数据库恢复;
  17. 日志收缩造成数据库损坏情况下的恢复;
  18. 仅剩损坏的备份文件情况下的恢复。

SQL Server数据库恢复工具SQLRescue技术特点:

只要SQL Server数据库的数据文件存在,我们就有办法帮您从数据文件中找回重要数据。
  1. 从数据文件中直接恢复数据
  2. 不能附加时直接恢复数据并生成新的数据库
  3. 系统表损坏的数据库修复
  4. 快速修复SQL 823错误、连接中断错误

SQL Server数据库恢复工具SQLRescue支持的版本:

Microsoft SQL Server 7.0, 2000, 2005, 2008, 2008R2, 2012, 2014, 2016, 2017,2019。
+-------------------------------------华丽的分割线-------------------------------------------------------------------------