提供7*24专业Sybase数据库远程及现场技术支持,Sybase ASE及Sybase SQL Anywhere数据库修复服务,
请联系电话: (微信),QQ: 289965371!
We supply technical support for Sybase ASE and Sybase SQL Anywhere, also have many years of experience in recovering data from damanged Sybase devices.
Please contact us:
Phone:
Wechat: 13811580958
QQ: 289965371 联系我们获取数据库技术支持!
Email: 289965371@qq.com
扫描下方微信,联系我们:
扫描雨翰数据恢复官方微信获取专业数据库恢复服务

 

随着Sybase被完全整合到SAP下,Sybase原来的支持网站被SAP Support Portal取代。
只有购买了SAP服务的用户才能使用账号登录SAP Support Portal进行介质下载、补丁升级、报Incident等。
考虑到Sybase数据库的初学者或者没有购买原厂服务的Sybase客户情况,现提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息。
在SAP Support Portal网站或者google上搜索Targeted CR List for ASE,可以看到针对不同版本的CR(CR表示Change Request)简单描述信息列表。
需要注意的是:Targeted CR List for ASE列出的CR虽然绝大多数是BUG,但有一些是更改需求。
以下提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息!

如有问题,请联系我!

QQ :289965371 联系我们获取数据库技术支持!
Email:
不仅仅包括BUG的详细描述信息,还包括首次报告BUG的平台、数据库版本以及BUG修复历史过程;有些BUG还提供了Workaround来临时解决该BUG带来问题。

 

CR:191701
CR Number:   191701
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 Mar 1999 Third Party Problem
Description
Printing a dw with different print drivers changes position of magnetic coding
Workaround Description
 I suggested they include an "adjustment utility" with the app. Allow the user to adjust the datawindow so that it prints correctly. Save the adjustments of x, or y, or height, whatever in an ini file or the registry. Apply the local adjustment before pr



CR:191723
CR Number:   191723
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 578 08 Apr 1999 Fixed
Description
Graph is trailing values when autoscale = off and the minimum and maximum values are decimal values like "90.4" and "100.6". Worked fine in PB 5



CR:191724
CR Number:   191724
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 2 14 Aug 2000 Fixed
Description
Cust would like to see <Profile> instead of <userId> for the prototype of MailLogon() in our online help and in our paper documentation.



CR:191732
CR Number:   191732
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
1017 08 Apr 1999 Fixed
Description
Queries that have retrieval arguments cannot be used for the source of datawindows



CR:191734
CR Number:   191734
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
1012 09 Mar 1999 Fixed
Description
When an internal error is recieved in a PB Wizard, a window appears to show the error. This window is non-modal.



CR:191739
CR Number:   191739
Product Name:   PB Enterprise
Product Component:   Structure - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Machine code only - reference embedded structure returned from a function directly (by dot notating from function call) causes a GPF in PB 6.5
Excample:
outer is a structur wich include the a other structure (here called type inner)

function getstruct()
outer temp
// set integer fields of structure to 1
temp.field1 = 1
temp.embedded.field1 = 1
// return structure
return temp

Calling the function which cause the gpf.
integer embed_field
embed_field = getstruct().embedded.field1

Workaround:
outer embed_struct
integer embed_field
embed_struct = getstruct()
embed_field = embed_struct.embedded.field1



CR:191740
CR Number:   191740
Product Name:   PB Enterprise
Product Component:   Help
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11 Aug 2000 Presently Not Targeted For Any Future Release Of This Product
Description
Edit Data Source for external datawindows changed dramatically in 7.0. In 5.0 and 6.0, you would access the columns though the Design/Data Source menu/Modify Result Set Description.

In 7.0, you modify the External Source datawindow through the Column Specifications view.
If the View is active, you will see Design/Data Source disabled in the menus. If the View is hidden, Design/Data Source will be active and clicking on it will bring up the Column Specifications view.

This is mentioned in the on-line books too.



CR:191744
CR Number:   191744
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Sep 2000 Presently Not Targeted For Any Future Release Of This Product
Description
Beta 7.0: Autoscript does not work for new controls inserted on a window or user object until the object is saved and either you exit out of the painter and come back in or bring focus to another control then back to the original control (see below).

In commandbutton_1 (cb_1):
I can type: this. and the list will display
I can type: parent. and the list will display
I can type: cb_2. but the list does not display
If I save the window, bring focus to cb_2 and then back to cb_1 and then type: cb_2. the list will display.



CR:191747
CR Number:   191747
Product Name:   PB Enterprise
Product Component:   DPB
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 31 Oct 2002 Fixed
Description
When more than 50 connections are made to a distributed PB application, the creation of an oleobject fails with code R0021.



CR:191748
CR Number:   191748
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB 7.0 Enhancement Request

Add to the prompt-for-criteria dw functionality, so the developer can "pre-select" a value. This value would appear in the prompt-for dialog to the user. User could change this value or not depending on his permissions.



CR:191751
CR Number:   191751
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 May 1999 Presently Not Targeted For Any Future Release Of This Product
Description
Specifically, page 2 has 5 basic steps that describe what the synchronizer does. Step 4 says it "copies changed source files". Since at least one customer was confused by that, perhaps it could say, "copies newer and/or larger source files".



CR:191754
CR Number:   191754
Product Name:   PB Enterprise
Product Component:   DW Graph
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Allow dw_control.Object.graphname.axis.MaximumValue and
dw_control.Object.graphname.axis.MinimumValue to accept quoted datawindow painter expressions.



CR:191773
CR Number:   191773
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 Fixed
Description
Doc update: When sharing dws, that any secondary dddws are not retrieved



CR:191782
CR Number:   191782
Product Name:   PB Enterprise
Product Component:   Table Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 595 31 Mar 1999 Fixed
Description
6.5 builds > 530 Regression: (PBIN760.DLL) Informix db.
Extended Attributes are not displayed in the Table Painter. They all display the defaults. If you modify any of them, say the Header, save it, exit out and come back it the change is no longer there.



CR:191816
CR Number:   191816
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.0 25 Feb 2004 Fixed
Description
Would like the ability to put a horizontal line <HL> in the data for HTML output (either SaveAs(HTMLTable!) or HTML datawindow output. This is a regression from 6.5.

In 6.5, you could use '<HL>' in a computed field anywhere and get a horizontal line in SaveAs..(HTMLTable!) output but in 7.0 it escapes the greater than and less than signs with an ampersand. It has the same behavior for the HTML Datawindow output. This is a more generalized need to allow things like links or SRC tags in computed fields to be output "as is" as was the case in PB 6.5.

A new attribute for computed fields "ValueIsHTML" has been added to 8.0 to allow full support of this functionality. This is/will be available in 7.0.2 ebf too but only through Modify() of the attribute. This is so you won't require a migration.

Customers using 6.5 computed fields needing this functionality (with Web.PB or SaveAs(HTMLTable!) to move to 7.0 can make a few changes to their code and get this functionality back..



CR:191823
CR Number:   191823
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Intensive assign value to array items is 4 slower in V6.5 than V5.04



CR:191825
CR Number:   191825
Product Name:   PB Enterprise
Product Component:   SQL Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   5.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1048 27 Apr 1999 Fixed
Description
Get union not compatible message in graphic mode even if union has a valid syntax.

Steps to reproduce :
1. Connect to our sql anywhere psdemodb database
2. Create a new grid datawindow
3. Select employee table
4. Select emp_id, emp_fname columns
5. Go in design/unions menu to create a new union in graphics mode
6. Select employee table
7. Select emp_id, street columns
8. Click on return painter to validate the union => Get error message 'This union is not union compatible', but this union is compatible!!!

NB: If you go in syntax mode and you manually set the same query then it works



CR:191841
CR Number:   191841
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
09 Apr 1999 Fixed
Description
Specify an edit mask with more than 108 characters leads to a GPF



CR:191863
CR Number:   191863
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
PB 7.0.00 ENHANCEMENT REQUEST--Autoscript feature

A nice enhancement to the autoscript feature would be to enable to programmer to choose how the selection list pops up. That is, should it execute via a pause... if so, after how long of a pause. May we always want it to show up immediately after we append the dot to a class name. Maybe we could use the new keyboard shortcut customization feature to invoke the popup list with a keyboard shortcut. I would prefer to press CTRL+DownArrow to invoke it myself.



CR:191882
CR Number:   191882
Product Name:   PB Enterprise
Product Component:   MAPI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request: Running MAPI application in batch mode



CR:191945
CR Number:   191945
Product Name:   PB Enterprise
Product Component:   Help
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
12 Apr 1999 Fixed
Description
SETFULLSTATE

RETURN CODE CHANGE actually returns a NULL not a 3 when the following conditions are present: No DataWindow object associated with DataWindow control or DataStore; new one assigned from DataWindow blob

USAGE SECTION CHANGE If the target of SetFullState does not have a DataWindow object associated with it, the blob will assign one. In this case, SetFullState has the effect of setting the DataObject property for the target.

Response from Development on this is as follows: We do not populate the dataobject property hence it returns a null, then the above mentioned script from help is incorrect that it gets assigned.



CR:191977
CR Number:   191977
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Mar 1999 Not a Bug
Description
Datawindow with a checkbox style column. Insert a new row. Enter other information, but do not tab to or click on the checkbox. Instead of being assigned the value for "Off" specified in the properties for that column, the data value is left as NULL, which causes a database error when the column does not allow NULLs.

Solution: Checkbox columns are implicitly required so the FindRequired function is one way to handle this problem. You could also set
the initial value of the column.



CR:191989
CR Number:   191989
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Feb 2001 Fixed
Description
Component deactivation fails with the following error:
AFLIB Messages: 18241/11/0: Transaction::Rollback(): Failed to
deactivate an instance of math/addcomponent.

Problem occurs when the component has the following properties:
1. Participating in a transaction
2. Times out (demarcation/deactivation is not checked)
3. There's code in the deactivate event that disconnects from a
connection cache.



CR:192063
CR Number:   192063
Product Name:   PB Enterprise
Product Component:   DW DDDW
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Aug 1999 Not reproducible with latest version of the product available as of Resolution Date
Description
Choose 10,001 in Dropdown, press tab key, then item indicates 10,000



CR:192065
CR Number:   192065
Product Name:   PB Enterprise
Product Component:   Generators
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB should be able to generate JAVA Byte code and should be better integrated with PowerSide and PowerJ and Jaguar
- Add a JAVA generator to PB. So that PowerBuilder is able to generate PCode or Machine Code or Java Byte code for a whole PowerBuilder Application.
- Integrate PowerSide into PowerBuilder so that a developer is able to generate HTML inside the PB development enviroment (Example.: Should be able to edit and design the HTML Part of the datawindow)
- Integrate PowerBuilder and PowerJ so that both tools can be used for Java development
- Better integration between PB and Jaguar. (Automatic generation of Jaguar components for a Datawindow see 192165.
Better error handling: see CR 187449, Better Database connection handling see 184098)



CR:192072
CR Number:   192072
Product Name:   PB Enterprise
Product Component:   DW Synchronization
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 18 May 1999 Fixed
Description
6.5 EBF build 545 regression: SetFullState does not display a v scroll bar.



CR:192073
CR Number:   192073
Product Name:   PB Enterprise
Product Component:   DW Synchronization
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 18 Jun 1999 Fixed
Description
6.5 EBF build 545 regression: SetFullState memory leak.



CR:192076
CR Number:   192076
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1013 06 Apr 1999 Fixed
Description
PB7.0 Beta: Line controls on a window do not display proper thickness



CR:192082
CR Number:   192082
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Open
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Beta 7.0: When in a painter, when you single click on a control, the property view reflects the properties for that control, but the script painter reflects the script for the previously selected control. You must DOUBLE-CLICK on the control to see its script.

Developers comments: This is not a bug, works as designed.

Product Support Engineering comments: Submit as a New Feature Request



CR:192087
CR Number:   192087
Product Name:   PB Enterprise
Product Component:   DB Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC0 29 Mar 1999 Not a Bug
Description
Beta 7.0: When in the database painter, you must double click on a column in order to view the attributes (or properties ) of that column, In other painters, you need only single click on the object to change the property sheet.

PER DEVELOPMENT:
This was a conscious design decision because so much of the information displayed in the db painter is db driven. Instead of always retreiving data/information when an item is selected, users must explicitly choose to look at the properties by either double clicking or RMB and selecting properties. This would be painful against some remote servers such as DB2 that have thousands of objects. This will not be changed.



CR:192096
CR Number:   192096
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 594 05 Apr 1999 Fixed
Description
Connecting to MS SQL Server 7.0 and creating a DataWindow from stored procedure that has datetime datatype as input argument, the following error occurs:
"Cannot create datawindow: Error converting datatype varchar to datetime."



CR:192099
CR Number:   192099
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Aug 1999 Not a Bug
Description
When using the libraryexport and than creating a dw
using dw_1.create, shows incorrect or no value in the computed field.
Problem happens in development and runtime.

The expression for the computed field is 1.5*1.6.

Using
ls_syntax = LibraryExport("decimalpoint2.pbl", "d_test2",ExportDatawindow!)
dw_1.create(ls_syntax)

shows the dw in the dw control but the computed field is not evaluated or evaluated
incorrectly.



CR:192103
CR Number:   192103
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
03 Apr 2000 Fixed
Description
PB 7.0 Beta: Nested reports with retrival arguments, painter problem.
Fixed in 7.0 build 7021



CR:192134
CR Number:   192134
Product Name:   PB Enterprise
Product Component:   MAPI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 576 05 Apr 1999 Fixed
Description
Simple email application worked fine using 6.5 GA. Worked okay through build 510. Starting with the next weekly build, build 515, you get a Smartheap Library error: MEM_BAD_POINTER. Also broken using beta 7.0 build 5024.



CR:192137
CR Number:   192137
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1012 22 Apr 1999 Fixed
Description
Global search in library painter has a long pause
before search begins and there is no indicator of action.

Problem is noticeable when the code examples is the selected/current
application.



CR:192164
CR Number:   192164
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Use Painters (for example.: Window Painter and UO Painter) for a WYSIWYG HTML generation. It's known that not all controls can be used but a lot of things can be used.



CR:192165
CR Number:   192165
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Today it's only possible to use SPUD. If you look forward, it should be possible to use the Datawindow as a Codegenerator for Jaguar Components
(use the SELECT statemente insert, update and delete functions) It should be possible to generte this components as Java or C++
!!!WITHOUT blob (getfulstate) we had a non Sybase proprietary solution!!! This sould include as well transactions over several datawindows!!!



CR:192166
CR Number:   192166
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
a transfer PowerScript to JavaScript/DynaScript could be used for example
a) in the validation of a Datawindow
b) it could be used for a code generation for Dynamo -> HTML as Outcome.



CR:192167
CR Number:   192167
Product Name:   PB Enterprise
Product Component:   DB Informix
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 589 06 Apr 1999 Fixed
Description
Informix empty strings of type varchar are sometimes incorrectly retrieved into the DataWindow as NULL values

Developer: There are two problems this causes:
To fix data retrieval problem, you must install SqliNet 9.20 or higher
To fix update problem, PBINxxx.DLL must be 6.5.1 (build 620)



CR:192184
CR Number:   192184
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB already has an expression for format of a column on a dw which is how a field gets displayed but
what I need before is to conditionally change the format in what they are keying in
e.g.:

We have a system that copes with mutli companies and each company has a
different way of keying in a certain code e.g.:

company 1 = ### ### ###
company 2 = #### ######
company 3 = ## ########

so if you had a expresion for the edit mask it would a whole lot easier to, at the moment its done with
allot of code in the rowfocuschanged event which is messy !



CR:192189
CR Number:   192189
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
When you add a button on a datawindow. it would be good to have a text expression dialog box available for the button to allow you to change the text conditionally in the datawindow painter.



CR:192193
CR Number:   192193
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.01
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Cust would like an enhancement to get number of lines of code in PBL's (from his library painter) or in a compiled PBD or in a dll (using a specific function in this case)



CR:192195
CR Number:   192195
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement request: Add required property to the expressions of a column in a dw.
Steps to reproduce:
1. Open an existing dw. Select a column and choose Properties.
2. Click on the Edit tab, there is a property on the edit tab of fields called "Required".
If this is checked you need to enter a value before coming off a column.
The problem with this is that it makes all the columns for all of the rows required.

Customer has a lot of datawindows where a field is required dependent on another field value.
His workaround is he has to do a for loop before update to check for these. (time consuming
and annoying)

Customer quite often need to make a field required conditionally on whether they
have entered a certain value in a field on that row



CR:192199
CR Number:   192199
Product Name:   PB Enterprise
Product Component:   DW DDDW
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Apr 2000 Fixed
Description
This looks similar to CR 160765, with the difference being that in that case the 'data column' was numeric and in this case it is a string.

DDDW with a string Null 'data column' with a corresponding display value, in this case the word "none". Problem is that the display value does not remain after tabbing off row. The user is allowed to select it but it does not remain in column. In PB 5.0 - 5.3 the corresponding display value of 'none' could be selected and would remain in place when user tabbed off column.

This worked in PB 5.0 - 5.0.3 but does not work in PB 5.0.4, PB 6.0,6.5 through build 575 or PB 7.0 build 5025.

Workaround: Put a blank space in rather than null and you can select and retain the value.



CR:192201
CR Number:   192201
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Oct 2007 Presently Not Targeted For Any Future Release Of This Product
Description
Build up a new PFC and templates for distributed application which can be used with Jaguar and PowerDynamo



CR:192208
CR Number:   192208
Product Name:   PB Enterprise
Product Component:   Application Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Application painter crashes on open (and sometimes close) after a new object (such as a window) has been added.



CR:192210
CR Number:   192210
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   5.0.04
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
In Grid style datawindow preview, current column resizing (small to large) causes data overlap with left-side column(s). This is in spite of the fact that that the current column is resized to large (thus adequate for data display )- e.g. data in the 3rd column will be displayed in the 2nd column and when exit from dw preview -2nd and 3rd columns are overlapping each other in the dw painter.

This seems to be a dw display problem because when the dw is saved to psr format, the columns are displayed correctly with no overlap.



CR:192228
CR Number:   192228
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Mar 1999 Not a Bug
Description
PB 7.0 Beta: Script Painter no longer provides Import/Export capabilities



CR:192237
CR Number:   192237
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1014 09 Apr 1999 Fixed
Description
GPF on dw stored proc update with disablebind=1.
Reproduced for ODBC to ASA EA studio demo db V3, ODBC to SQL Anywhere PB demo db V6.

WORKAROUND: Use disablebind=0 ( or do not explicitly set the dbparm. Disablebind is off by default.)



CR:192241
CR Number:   192241
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC2 08 Mar 1999 Fixed
Description
When a pb nvo is deployed to jaguar and that nvo has
instance variables declaring objects (such as TransactionServer, ErrorLogging,
ContextKeyword or structures). running a pb client app thru the debugger that calls
the deployed nvo will crash pb when you try to expand (by clicking the + sign) it.

The following error message appears:
pb70.exe application error
The instruction at "0x112acf9d" referenced memory at "0x00000004". The
memory could not be "read". Click ok to terminate the application.



CR:192294
CR Number:   192294
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:
Under the menu item of Window, customer believes there should not be "..."
after the "Browser" and "To Do List" menu items in Powerbuilder 7.

Customer feels they should be placed under a separate menu item such as Tools,
since looking under Window for them is not intuitive.



CR:192296
CR Number:   192296
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:
When the property name is changed for a column in the dw painter, the column specification panel
does not reflect the change. You need to close the panel and reopen it for the change to show.

Have the ability to refresh the column specification panel when a change is made in the dw painter, without
closing it.



CR:192301
CR Number:   192301
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   5.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 585 01 Apr 1999 Fixed
Description
Unable to use functions in Formula One OCX (v5, v6)



CR:192304
CR Number:   192304
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 09 Apr 1999 Fixed
Description
Rows To Disk setting on a DW, fails when importing or retrieving over 220,000 rows



CR:192314
CR Number:   192314
Product Name:   PB Enterprise
Product Component:   Project Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
24 Mar 1999 Not reproducible with latest version of the product available as of Resolution Date
Description
When attempting to create a second com/mts project
within the same PB session, pb crashes with the following error:

On nt:
PB70.exe Application Error
The instruction at "0x112bcdcb" referenced memory at "0x066c0f8e". The memory
could not be "read". Click ok to terminate the application.

On win95:
PB70 caused an invalid page fault in module pbvm70.dll at 0157:112bcd9b



CR:192321
CR Number:   192321
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 577 27 Apr 1999 Fixed
Description
You cannot reference public synonyms in the datawndow painter or the database painter if Delimitidentifier is set to "No". You get error Ora 00903 - Invalid table name.



CR:192407
CR Number:   192407
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
09 Mar 1999 Fixed
Description
PB crashes in the dw painter when selecting a column
that has a edit style of dddw. Once a dw is associated as the dddw in the edit style tab,
and you go back and click on that column in the dw painter, pb crashes.

pb70.exe Application Error
The instruction at "0x113b99e0" referenced at "0x00000065". The memory
could not be "read".
Click on OK to terminate the application.

Using ASE 6.0x and the EAS Demo DB.



CR:192452
CR Number:   192452
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
5028 18 Mar 1999 Fixed
Description
PB crashes in dw painter when selecting multiple
computed fields.

The following error occurs:
pb70.exe - Application Error
The instruction at "0x1083ffd4d" referenced memory at "0x00000008". The
memory could not be "read". Click ok to terminate the application.



CR:192482
CR Number:   192482
Product Name:   PB Enterprise
Product Component:   DB Sybase System
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1060 07 Mar 2000 Fixed
Description
The customer wants to save a single space in a column in his database. By default Sybase System 10, 11.5 and ASE 11.92 right trims any spaces in a varchar column. E.G. if "a " was saved into the database "a" would be retrieved into the datawindow. If a single space is stored in the column, it is ignored when it is retrieved back into the datawindow. This works as intended if you connect to the Sybase database (10, 11.5 or ASE 11.92) with the Intersolve ODBC driver version 2.10.0.1
Workaround Description
 Temporary workaround to use the Intersolve ODBC driver version 2.10.0.1



CR:192492
CR Number:   192492
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.2 8023 20 Dec 2000 Fixed
Description
PB 7.0: Performance Problems with libraries on the Network

At design time opening a window is much slower in PB7 than in PB6.
Opening the window in runtime takes about as long in PB7 as in PB6

Much more information is required to be read in for the new window layout in the painter.



CR:192515
CR Number:   192515
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0.0 20 Apr 2000 Fixed
Description
Beta 7.0 Regression: Changing the Application font properties for Text, Column, Header, and Label are not applied when building a new datawindow. They are however, applied for the static text if you create a new window or user object, but not a datawindow.



CR:192517
CR Number:   192517
Product Name:   PB Enterprise
Product Component:   DB Other
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 581 07 Apr 1999 Fixed
Description
Tablecriteria with pbdir against TRS is not working.



CR:192530
CR Number:   192530
Product Name:   PB Enterprise
Product Component:   DB Informix
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 580 17 Mar 1999 Fixed
Description
Dynamic SQL using an integer column in where clause is being described as a float in the informix native driver.



CR:192570
CR Number:   192570
Product Name:   PB Enterprise
Product Component:   Debugger
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Request that list of object was organized by object class within library, or even if it was alphabetical within library.



CR:192571
CR Number:   192571
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Jun 1999 Not a Bug
Description
PB 7.0 beta: Problems with the oneclickactivate & twoclickactivate on listviews.



CR:192572
CR Number:   192572
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Jun 1999 Fixed
Description
When a pbl is deleted and than recreated with the same name,
the items from the "to do list" do not get removed. It appends items to the list.

It seems that if the pbl is deleted, the items from the "to do list" should be removed/wiped out
too.



CR:192592
CR Number:   192592
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:
Have the "To Do List" refresh automatically without having to close and reopen the "To Do List".

For example, if you click on a task that opens to a wizard to generate another object. New "To Do List" entries
are created. But you have to close the "To Do List" and reopen it to see the new task.



CR:192638
CR Number:   192638
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 EBF1 6005 15 Apr 1999 Fixed
Description
When scrolling down a Grid Datawindow with the thumb in the verical srollbar and scrolling back, vertical lines are displayed.



CR:192660
CR Number:   192660
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Apr 1999 Not a Bug
Description
When Windows regional settings are set to US English (also happens with Trinidad, Jamaica and Caribbean English flavours) DW Edit styles or Edit masks or Formats of #,##0.00 cause the displayed data in these columns to be divided by a factor of 100 (eg 50.00 -> 0,000.50).

This works OK with all other English regional settings (Canada, Australia, South Africa etc)
The same problem exists with DM, FF, Pts (German Marks, French Francs, Spanish pesetas etc) using US English settings but not with the other English settings (except the above 3 Caribbean ones)

Simple Workaround: Prefix a '\' before the sign - works with all regional settings.
Workaround Description
 Prefix a '\' before the sign - works with all regional settings
eg '#,##0.00' -> '\#,##0.00'



CR:192676
CR Number:   192676
Product Name:   PB Enterprise
Product Component:   Printing
Status:   Closed
OS:   HP-UX 10.20
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
PB hangs when the print to file checkbox is checked on
the print dialog box.

The following error occurs before pb hangs:
Can't access this folder
Path is too long



CR:192698
CR Number:   192698
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
A crash can occur calling the function LinkTo of an OLE control when the OLE Server is busy or not started.
Work-around is to set redraw off for the control before the LinkTo call.



CR:192750
CR Number:   192750
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
9008 07 Aug 2000 Fixed
Description
Netscape 4.x using a dddw with the property "Required" set causes an endless validation messagebox to come up (from the Javascript). 'Item <picked_item> does not pass validation test'

When selecting an item from the dropdowndatawindow that has "Required" and "Empty String is Null" set, you will get a messagebox "Item 'null' does not pass validation test" regardless of which value is selected from the drop down list. With a dddw, there should be data in the buffer after the user has selected an item and you should never get this error.



CR:192758
CR Number:   192758
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Dec 2007 Fixed
Description
Blob columns in label datawindows do not populate correctly. Second and subseqeuent pages repeat the blob data from the first page.



CR:192773
CR Number:   192773
Product Name:   PB Enterprise
Product Component:   Project Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 603 31 Oct 2002 Fixed
Description
Compilation of a COM object fails with a BAD_MEM_POINTER error when there are more than 14 arguments.



CR:192780
CR Number:   192780
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Apr 1999 Fixed
Description
Use Original check box in DW Stored Procedure Update gets reset after saving.

The new 7.0 feature, DataWindow Stored Procedure Update, has a check box called "Use Original". When you setup the SPs for the Update, Insert and Delete tabs and check off the Use Original box for some of the arguments, you will notice that the check box changes are saved to different tabs when you view the DW SP update window again after saving it. This behavior differs based on the order in which you create the SPs. For example:

1) Going Left to Right (Update, Insert, Delete tab)

If you select a procedure for the Update tab and then check off the Use Original box for one of the arguments, then do the same for the Insert and Delete tab but check off the Use Original box for different arguments, you will notice that all the Use Original check boxes are set to whatever order was set in the LAST tab, in this case the Delete tab.

2) Going Right to Left (Delete, Insert, Update tab)

If you select a procedure for the Delete tab and then check off the Use Original box for one of the arguments, then do the same for the Insert and Update tab but check off the Use Original box for different arguments, you will notice that all the Use Original check boxes are set to whatever order was set in the MIDDLE tab, in this case the Insert tab.

3) Mixing up the orders (Insert, Delete, Update tab)

There is no consistent pattern as to what the check boxes are set to when you mix up the order of entering the procedures for each of the tabs. In any case, they are not set
correctly.

I have also noticed the Use Original check box disappearing and also unicode or garbage characters showing up in the Argument names for all the tabs but I have not been able to reproduce these behaviors.



CR:192831
CR Number:   192831
Product Name:   PB Enterprise
Product Component:   DW Expression
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1017 15 Apr 1999 Fixed
Description
A computed field in a datawindow in the header or footer band no longer paints when the datawindow displays (before there was a retrieval). It really doesn't matter what the expression is - Now(), etc. This worked fine in pb 6.x.

In order for the computed expression to show, you must code in setredraw(true).
In pb 6.x, you didn't have to do this.



CR:192874
CR Number:   192874
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Open
OS:   Microsoft Windows 95
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Not a Bug
Description
Enhancment Request: In PB 5 and PB 6, you could go into the window properties, go to the position tab and move the 'window' around to the position you wanted to have it at. You could also right mouse click on the lower window. A popup menu came up with "Center Horizontally" and "Center Vertically." These options are no longer available in PB 7.0



CR:192895
CR Number:   192895
Product Name:   PB Enterprise
Product Component:   DB Sybase System
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 584 07 Apr 1999 Fixed
Description
Datawindow retrieves under SYC native driver take a long time when the source is a stored procedure and the retrieval is done asynchronously.



CR:192908
CR Number:   192908
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Request for SetLibraryList to work dynamically at any time in the application when they want to call it, not just at the open of the application as is recommended. Furthermore, they want the current (prior) cache to be blown away at the time that the function is called so that old information from the previous path is not maintained in cache.



CR:192909
CR Number:   192909
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10165 30 Apr 2002 Fixed
Description
A datastore is shared with two child datawindows. A filter on the datastore causes a gpf.



CR:192914
CR Number:   192914
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
PBMSS70.dll - enhance for the new features of SQL Server 7.0 for PB7.0 GA,



CR:192917
CR Number:   192917
Product Name:   PB Enterprise
Product Component:   DB Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2004 EOL'd version. Not to be Fixed.
Description
When in the database painter, make a change to the display width extended attribute in the column view
Then go to the tree view of the same table and change the focus to another column. PB7 asks you to save changes before allowing the focus to another column in the same table.
This is most annoying. Changes to columns in a single table should be done as a unit of work, as in the prior release, and should only prompt for changes when exiting the table and not saving.

Enhancement - Changes to columns in a single table should be done as a UOW



CR:192919
CR Number:   192919
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11 Mar 1999 Duplicate
Description
Enhancement Request:
Customer would like to have powertips on treeviews and command buttons. Powertips are only available for
toolbars. Tags are only used on mdi frames.



CR:192938
CR Number:   192938
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 EBF1 06 Jul 1999 Fixed
Description
When a "normal" user tries to choose SCC API from the Library painter, source control vendor drop down, the following error message is displayed:

"Unable to Read Registry Value: SOFTWARE\Powersoft\ObjectCycle\2.0.00\MSIDE\SCCServerName"

NOTE: The above error message is specific to ObjectCycle, but you can reproduce this against other 3rd party vendors.

If the user has administrative rights then this error message is not displayed. Also if you give "Full Control" to this registry key via REGEDT32, you will have no problems.
Workaround Description
 If the user has administrative rights then this error message is not displayed. Also if you give "Full Control" to this registry key via REGEDT32, you will have no problems, there is also an official workaround in faxline document 44425.



CR:192982
CR Number:   192982
Product Name:   PB Enterprise
Product Component:   DB OLE DB
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 2 2051 16 Mar 2004 EOL'd version. Not to be Fixed.
Description
OLEDB. If you try to build a dw based on a stored procedure data source, you get an error message when you click OK in the window "Ready to Create Tabular DataWindow". This problems occurs with the following providers only:

MSDAORA connect to Oracle 8.0 using the Net8.05 client:
Error: "Cannot create datawindow Microsoft OLE DB Provider for Oracle ORA-00900 invalid SQL statement" 1 execute system.CR169371_pss;0 RC1 = 0"
Note, when you select the sp, you will see a message stating "The database does not currently support retrieval of procedure text."
Also, this problems does not happen with the native O84 driver.

Intersolv Oracle 7 and Oracle 8 OLEDB connected to Oracle 7.x via SQLNet 2.3.x and Oracle 8.05 via Net8.05:
Because of CR192975, you cannot see the sps list when you are connected with the Oracle 7 provider.
Error: "Cannot create datawindow. SQLSTATE=37000 Intersolv Oracle8 OLEDB Provider [Intersolv][OLEDB Oracle8 Provider][Oracle8] ORA-00900:
Invalid SQL Statement"
Note, when you select the sp, you will see a message stating "The database does not currently support retrieval of procedure text."
Also, this problems does not happen with the native O84 driver.


Intersolv Informix 7 and Infomrix 9 OLEDB connected to Informix 7.x server via I-Connect 7.x and Informix 9.x servcer via I-Connect 9.16:
Error: "Cannot create datawindow. SQLSTATE=37000 Intersolv Informix7 OLEDB Provider [Intersolv][OLEDB Informix Provider][Informix] A syntax error has occurred.
Note this problem does not occur with the native IN7 and IN9 drivers.



CR:192988
CR Number:   192988
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Mar 1999 Duplicate
Description
On some versions of Windows 95, printing an object from the library painter only produces one blank page.



CR:193071
CR Number:   193071
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Apr 1999 Fixed
Description
Beta 7.0: External DataWindow: Column Specifications allows you to INSERT ROW and DELETE ROW by rmb clicking in the Column Specifications view, but there is no ADD ROW option as in previous versions. Using the ADD option would put the new item at the bottom. Right now the only way you an add a new row is to TAB. Inserting a row inserts one above the row where the cursor is currently at.



CR:193074
CR Number:   193074
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:
Remove or change the warning message when retrieval arguments are created but
not used when creating the dw.

If a retrieval argument is not used in a Select statement than a message pops up
saying:
"The (...) argument for the Select statement was not referenced. Do you wish to continue anyway?

The customer feels that this a popular way of passing data to a datawindow for sections not used
by the dw select.

The customer proposes the following message instead:
"The arguments were not referenced in the Select and are assumed to be datawindow arguments?

And in the datawindow, why not just call these "arguments" and not "retrieval arguments".



CR:193102
CR Number:   193102
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 EBF1 6005 08 Apr 1999 Fixed
Description
When previewing a datawindow with print preview + print preview zoom (30%) if you scroll right down to the bottom then scroll back up using the slide control on the scrollbar (not arrow keys/buttons) PB freezes up. Need to kill it using task manager.



CR:193114
CR Number:   193114
Product Name:   PB Enterprise
Product Component:   Machine Code Deployment
Status:   Closed
OS:   MS Windows 3.1
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Jun 1999 Presently Not Targeted For Any Future Release Of This Product
Description
6.5 Regression: 16 bit machine code exe fails in Windows 3.1 (works in 5.0.02)



CR:193128
CR Number:   193128
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1021 19 Apr 1999 Fixed
Description
Beta 7.0: Changes made to one view (ie like the script view) under Design -> Options are not reflected in other script views lready opened. Change Design Options such as font type while script view '1' has focus. Script view '2' will not take on the font change but if you look in the Design Options dialog it will show the changes made. If you click OK, then the changes are reflected in the second view.



CR:193129
CR Number:   193129
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Fixed
Description
In the online help under transport objects, the list of options
does not include threadpooling.

Threadpooling is a new option for the transport object for pb 6.5 and 7.0.

ThreadPooling: (valid values: 1 = on, 0 = off, default = 0 in pb6.5 and pb7.0)
Feature that was added to 6.5 to increase scalability. The basic
concept of this feature is that as a connection is completed, instead of destroying
OS process threads, they get pooled. It is faster to pull a thread out of a pool than
to destroy and recreate one via the OS. When a client is not processing anything,
the thread is available for other active users.



CR:193138
CR Number:   193138
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Datawindow update results in a SQLSTATE = 07006 (Sybase)[ODBC Driver]: invalid host variable. No changes made to database
or SQLSTATE=07006 [Sybase}{ODBC Driver}: cannot convert date/time to a decimal. No changes made to database when attempting to update database when two column values have been deleted and there is a scripted change to a DateTime field. If only one of the columns is nulled out or if the script to update the datetime field is removed the update processes without the above errors.

WORKAROUND: DisableBind =1



CR:193144
CR Number:   193144
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 585 02 Apr 1999 Fixed
Description
When pb calls a ole method that takes two arguments
(Variant) the method returns incorrect results.

The method takes two arguments of:
ole_1.object.meth1("This is string1", "This is string2")

Pb will return the following:
This is string2
This is string2

Pb should be returning:
This is string1
This is string2



CR:193166
CR Number:   193166
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
19 Dec 2000 Fixed
Description
New entry in a DropDownListBox does not get accepted when the drop down list is displayed and you tab to a other control in a window. Instead of that after leaving an existing entry of the DDLB is getting displayed.



CR:193169
CR Number:   193169
Product Name:   PB Enterprise
Product Component:   DW DDDW
Status:   Closed
OS:   Microsoft Windows 98
Original Version:   5.0.04
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
The problem appears when the datawindow has column with a dddw edit style.
PowerBuilder retrieves ENDLESSLY when focus is on the column with dddw edit style AND dddw is empty(no data) AND QueryMode=Yes.
Workaround Description
 1) dw_1.GetChild("emp_id", idwc_temp) //dddw edit style ;... if idwc_temp.rowcount() = 0 then // If rowcount=0, insert a blank row ; idwc_temp.insertrow(0) 2)Or Set tab order property of column to read only if querymode=yes dw_1.SetTabOrder(1, 0)



CR:193170
CR Number:   193170
Product Name:   PB Enterprise
Product Component:   DB Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Mar 2004 EOL'd version. Not to be Fixed.
Description
Database Painter. If you retrieve from a large table and then try to retrieve from a different table while PB is still retrieving from the first table, you get a message stating "Only cancel command is allowed when the rows are pending".

However, once you get this error message, you cannot get rid of it. If you try to retrieve from another table, you still get the same message. The only way to get rid of it is to disconnect and reconnect to the database



CR:193187
CR Number:   193187
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
This may be a duplicate of an old bug CR152406. Reported by customer again as part of PB 7.0 Beta.

When previewing or running a crosstab datawindow and the user uses the mouse to drag the right side of a column to the left so that nothing in the column is visible and then drags the right side back out again the data will be visible, but the column header is missing.



CR:193192
CR Number:   193192
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
When using the dtawindow Find() function, if the expression contains two consecutive '%', you will get a GPF in PB 6.5. You will get 0 (nothing found) in PB 7.



CR:193203
CR Number:   193203
Product Name:   PB Enterprise
Product Component:   Help
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC1 30 Mar 1999 Fixed
Description
Some of the new window controls don't have links to their
properties/functions and events the way some of the other controls do.
(For example, listview and treeview).

The new controls are:
Progressbar
- HProgressBar
- VProgressBar
Static Hyperlink control
Picture Hyperlink control

For consistency and clarity, these new controls should have links to show a description
of properties/events/function the way treeview, listviews controls do.

The format is inconsistant to other controls.





--------------------------------------华丽的分割线-------------------------------------------------------------------------

Sybase SQL Anywhere数据库恢复工具ReadASADB:

之前就已经研发成功了能够从Sybase SQL Anywhere的DB文件中恢复数据的工具: ReadASADB。
此工具支持ASA v5.0, v6.0, v7.0, v8.0, v9.0, v10.0, v11.0, v12.0, v16.0, v17.0等版本。
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具。
恢复Sybase SQL Anywhere的工具在国内处于领先水平。

Sybase SQL Anywhere数据库恢复工具ReadASADB功能
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具
  1. 适用于所有的SQL Anywhere版本    包括:5.x,6.x,7.x,8.x,9.x,10.x,11.x,12.x,16.x,17.x
  2. 适用于所有的UltraLite版本
  3. 能够恢复出来表结构和数据
  4. 能够恢复自定义数据类型
  5. 能够恢复存储过程等对象的语法
  6. 能够导出到目标数据库
  7. 能够导出到SQL文件并生成导入脚本
  8. 支持多种字符集,包括:cp850、cp936、gb18030、utf8等
  9. 能够恢复未加密或者简单加密类型的数据
  10. 简单易用
  11. 限制:不支持AES加密的数据文件
请参考:研发成功了从Sybase SQL Anywhere的DB文件上恢复数据的工具
            SQL Anywhere数据库非常规恢复工具ReadASADB使用介绍

Sybase SQL Anywhere数据库恢复工具ReadASADB适用场景

各种误操作:

  1. 误截断表(truncate table)
  2. 误删除表(drop table)
  3. 错误的where条件误删数据
  4. 误删除db或log文件
  5. 误删除表中的字段

Sybase SQL Anywhere数据库恢复工具ReadASADB的应用场景:

1.因为物理磁盘故障、操作系统、系统软件方面或者掉电等等原因导致的Sybase SQL Anywhere数据库无法打开的情况;
2.误操作,包括truncate table,drop table,不正确的where条件导致的误删除等;
Sybase SQL Anywhere无法打开时,比较常见的错误是:Assertion failed。
如:
1、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Checkpoint log: invalid bitmap page -- transaction rolled back
2、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Page number on page does not match page requested -- transaction rolled back
3、Internal database error *** ERROR *** Assertion failed:200502 (9.0.2.2451) Checksum failure on page 23 -- transaction rolled back
4、File is shorter than expected
5、Internal database error *** ERROR *** Assertion failed: 201116 Invalid free list index page found while processing checkpoint log -- transaction rolled back
6、*** ERROR *** Assertion failed: 51901 Page for requested record not a table page or record not present on page
7、*** ERROR *** Assertion failed: 201417 (7.0.4.3541) Invalid count or free space offset detected on a table page
8、Internal database error *** ERROR *** Assertion failed: 201425 (8.0.3.5594) Invalid count or free space offset detected on a free list page -- transaction rolled back.
9、Internal database error *** ERROR *** Assertion failed: 100702 (8.0.1.2600) Unable to modify indexes for a row referenced in rollback log -- transaction rolled back


-------------------------------------------------------------------------------------------

Sybase ASE数据库恢复工具READSYBDEVICE:

一个不依赖数据库管理系统、直接从Sybase数据库设备文件上提取数据的业内领先的恢复工具!
能够从损坏的Sybase ASE设备文件(.dat)上提取数据的非常规恢复工具。

Sybase ASE数据库恢复工具READSYBDEVICE的主要功能:

  1. 被勒索病毒加密数据文件及备份文件情况下的恢复;
  2. 系统崩溃只剩下数据文件的情况下的恢复,甚至数据库文件不存在而只有损坏的备份文件情况下的恢复;
  3. 因断电、硬盘坏道等造成数据库文件损坏情况下的恢复;
  4. delete数据恢复、误update数据恢复、误删除表(drop)恢复、误truncate表恢复 等;
  5. 各种Sybase内部系统表损坏、索引错误的修复;
  6. master数据库损坏而无法正常运行情况下的恢复;
  7. Sybase数据库被标记为可疑,不可用等情况的恢复;
  8. Sybase数据库中数据文件内部出现坏块情况下的恢复;
  9. Sybase数据库无数据文件但有日志文件的情况下的恢复;
  10. Sybase数据库只有数据文件无任何日志文件的情况下的恢复;
  11. Sybase数据文件被误删除情况下的碎片提取恢复;
  12. 磁盘阵列上的Sybase数据库被误格式化情况下的数据库恢复;
  13. 数据库sysobjects等系统表损坏无法正常应用情况下的恢复;
  14. Sybase数据库还原数据库出现失败情况下的恢复;
  15. Sybase数据库只剩下损坏的备份文件情况下的恢复。

Sybase ASE数据库恢复工具READSYBDEVICE支持的版本:

Sybase ASE 11.0.x,11.5.x,11.9.x,12.0.x,12.5.x,15.0.x,15.5.x,15.7.x,16.0.x


-------------------------------------------------------------------------------------------

SQL Server数据库恢复工具SQLRescue:

一个不依赖数据库管理系统、直接从SQL Server数据库文件上提取数据的业内领先的恢复工具!
能够从损坏的SQL Server数据库文件(.mdf)上提取数据的非常规恢复工具。

SQL Server数据库恢复工具SQLRescue的主要功能:

  1. 系统崩溃只剩下数据文件的情况下的恢复,即无日志文件或者日志文件损坏情况下的恢复;
  2. 断电导致数据库文件损坏情况下的恢复;
  3. 硬盘坏道造成数据库损坏情况下的恢复;
  4. 数据文件内部存在坏页情况下的恢复;
  5. 企业管理器误删除数据表记录,管理软件误删除数据表记录的恢复;
  6. 并闩锁错误、格式化、误删除后导致软件不能使用的情况;
  7. 无法读取并闩锁页sysindexes失败情况下的修复;
  8. 数据文件被误删除情况下的碎片提取恢复;
  9. 系统表损坏、索引错误、误删除数据库表、删除记录的数据找回;
  10. master数据库损坏而无法正常运行情况下的恢复;
  11. 数据文件无法附加情况下的数据恢复;
  12. 数据库被标记为可疑,质疑,不可用等情况的恢复;
  13. 数据库sysobjects等系统表损坏情况下的恢复;
  14. 数据被误(drop、delete、truncate)删除表数据的恢复,误update后的数据恢复等;
  15. 还原时报一致性错误,错误823等情况下的数据恢复,各种错误提示的数据库文件修复;
  16. 数据库被误格式化等情况下的数据库恢复;
  17. 日志收缩造成数据库损坏情况下的恢复;
  18. 仅剩损坏的备份文件情况下的恢复。

SQL Server数据库恢复工具SQLRescue技术特点:

只要SQL Server数据库的数据文件存在,我们就有办法帮您从数据文件中找回重要数据。
  1. 从数据文件中直接恢复数据
  2. 不能附加时直接恢复数据并生成新的数据库
  3. 系统表损坏的数据库修复
  4. 快速修复SQL 823错误、连接中断错误

SQL Server数据库恢复工具SQLRescue支持的版本:

Microsoft SQL Server 7.0, 2000, 2005, 2008, 2008R2, 2012, 2014, 2016, 2017,2019。
+-------------------------------------华丽的分割线-------------------------------------------------------------------------