提供7*24专业Sybase数据库远程及现场技术支持,Sybase ASE及Sybase SQL Anywhere数据库修复服务,
请联系电话: (微信),QQ: 289965371!
We supply technical support for Sybase ASE and Sybase SQL Anywhere, also have many years of experience in recovering data from damanged Sybase devices.
Please contact us:
Phone:
Wechat: 13811580958
QQ: 289965371 联系我们获取数据库技术支持!
Email: 289965371@qq.com
扫描下方微信,联系我们:
扫描雨翰数据恢复官方微信获取专业数据库恢复服务

 

随着Sybase被完全整合到SAP下,Sybase原来的支持网站被SAP Support Portal取代。
只有购买了SAP服务的用户才能使用账号登录SAP Support Portal进行介质下载、补丁升级、报Incident等。
考虑到Sybase数据库的初学者或者没有购买原厂服务的Sybase客户情况,现提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息。
在SAP Support Portal网站或者google上搜索Targeted CR List for ASE,可以看到针对不同版本的CR(CR表示Change Request)简单描述信息列表。
需要注意的是:Targeted CR List for ASE列出的CR虽然绝大多数是BUG,但有一些是更改需求。
以下提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息!

如有问题,请联系我!

QQ :289965371 联系我们获取数据库技术支持!
Email:
不仅仅包括BUG的详细描述信息,还包括首次报告BUG的平台、数据库版本以及BUG修复历史过程;有些BUG还提供了Workaround来临时解决该BUG带来问题。

 

CR:189833
CR Number:   189833
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Jun 1999 Not a Bug
Description
Regression from PB 5.0.03. Does not exhibit problem when running with PB 5.0.03.

Starting with PB 5.0.04, including all version of PB 6.X and 7.0 the application results in a Powerbuilder Application Execution Error (R0035) Error: Error calling external object function coomandbars at line ....... OLE Automation connecting to Word 8 using (word.application.8) in all versions of PB. Application is failing in a customer developed Macro that is trying to change the CommandBars.



CR:189854
CR Number:   189854
Product Name:   PB Enterprise
Product Component:   Menu Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Feb 1999 Duplicate
Description
EAS3.0 beta - PB7 build 5011. New created user event from a menu is missing after being saved correctly when you exit and then reopen the menu.



CR:189888
CR Number:   189888
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 EBF1 14 Apr 2000 Fixed
Description
Need to be able to modify the column names of columns that are added to an external datawindow via the column specification view.



CR:189934
CR Number:   189934
Product Name:   PB Enterprise
Product Component:   Business Graphics
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 559 16 Feb 1999 Fixed
Description
Builds of PB 6.0/6.5 GA through build 540 are setting the colors of a pie graph using the SetDataStyle() function. The same syntax that was used in pb 6.0 GA through pb 6.5 build 540 does not change the color in either build 545 (current build) or Pb 7.0 build 5011.



CR:189963
CR Number:   189963
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 98
Original Version:   5.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
In datawindow querymode, criteria is supplied at runtime.
If querying for column = y, n, or null.
Criteria is entered in the appropriate column (when the dw is in querymode).
After data is retrieved and querymode turned off, there is no simple way to select a column on an "is null" criteria.
Workaround Description
 Hardcoded workaround: original_select = dw_1.Describe("DataWindow.Table.Select") ; where_clause = 'WHERE ( ~~~"product~~~".~~~"jif~~~" is null ) ' ; mod_string = "DataWindow.Table.Select=' " + original_select + where_clause + " ' " ;



CR:189973
CR Number:   189973
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
01 Mar 2002 Workaround
Description
A GIF with its transparent value set to a color on its image pallette does not display the color as transparent.

Applies to PictureButton, PictureHyperlink, and Picture controls on a Window.


A Picture Button is based on the Button control and cannot assume a different background color.

For Picture Hyperlink and Picture Controls there is an Architectural limitation on PowerBuilders internal control structure.CR 273347 (enhancement request) has been created for resolving the architectural limitation.

For a workaround datawindow userobjects can be used to achieve a similar result. A short technical document is available on http://my.sybase.com/detail?id=1018236.
Workaround Description
 See http://my.sybase.com/detail?id=1018236.



CR:189975
CR Number:   189975
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC2 5018 16 Feb 1999 Fixed
Description
7.0 Beta: Global functions invoked from datawindow expressions don't work.



CR:190025
CR Number:   190025
Product Name:   PB Enterprise
Product Component:   Machine Code Exe Creation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
When building a machine code exe and the
ascii symbol of alt + 159 is used in the pb script, pb will crash with a reference
memory exception error. (Open event of app painter for symbol.)

Works ok in pb 5.0.04 and win95.



CR:190065
CR Number:   190065
Product Name:   PB Enterprise
Product Component:   DB Informix
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 562 13 Feb 1999 Fixed
Description
When using the UpdateBlob() function with the Informix IN7 driver, the update fails on build after PowerBuilder 6.5 build 444 when the table to be updated is a temporary table.



CR:190070
CR Number:   190070
Product Name:   PB Enterprise
Product Component:   GenApp
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
5017 11 Feb 1999 Fixed
Description
When using the application template wizard and on the
"Name Individual Sheets" window you delete the names for sheets 2 and 3,
once you hit the finish button, the following error will show up:
Wizard Error:
Error generating d:\genapp.pbl, Reason is : Compiler Error.

If you click ok, pb creates a corrupted pbl.



CR:190079
CR Number:   190079
Product Name:   PB Enterprise
Product Component:   DW HTML
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
HTML DataWindow / Web DW does not display column pointers:
ASP/IIS: Setting the pointer to a non-default type is not displaying in the HTML DW.



CR:190081
CR Number:   190081
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC1 5021 17 Feb 1999 Fixed
Description
A change in 7.0 to include export headers ($PBExportHeader$..... & $PBExportComments$...) when an object is checked into a source managment system is causing an error when using ORC API import; ORCA functions PBORCA_CompileEntryImport() & PBORCA_CompileEntryImportList()



CR:190131
CR Number:   190131
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Need a SetProfileString function that control when the data are really written on disk



CR:190133
CR Number:   190133
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1020 22 Apr 1999 Fixed
Description
GPF during migration in a window which has a shared variable declared



CR:190143
CR Number:   190143
Product Name:   PB Enterprise
Product Component:   Automation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Call to PB Automation Server function with Argument type ANY by REFERENCE fails



CR:190145
CR Number:   190145
Product Name:   PB Enterprise
Product Component:   UO Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
10 Feb 1999 Fixed
Description
If you create a new user object of type datastore and create a function on the object with an argument. Saving the object may cause the argument name to change.



CR:190161
CR Number:   190161
Product Name:   PB Enterprise
Product Component:   Help
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Apr 1999 Fixed
Description
The help text and Datawindow reference should be updated to specify the data type for VerticalScrollMaximum and VerticalScrollPosition as longs, not integers.



CR:190286
CR Number:   190286
Product Name:   PB Enterprise
Product Component:   DB Sybase System
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.01
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Feb 1999 Third Party Problem
Description
Regression PB 6.5 ASE 11.5:
With European regional settings (decimal separator = comma)
Selecting into a double value with Embedded SQL numeric and decimal types truncates the decimal part.
Selecting into a decimal variable works fine.
This happens using the SYC interface but not with O73 or SQLAnywhere.



CR:190349
CR Number:   190349
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.0.01
Fixed Version Build Resolution Date Closure Code (If Appropriate)
08 Mar 2001 Not a Bug
Description
PB Library for Lotus Notes. Customers forms database has random failures when trying to retrieve form based on clicking in a row in the database. It is failing in the of_retrieve() of n_cst_notes_service on the call to the Lotus Notes HiTest C API external function PBhtgetform() . When it fails it returns a '0' rather than a value for iul_dochandle. All other arguments to the function appear to be the same whether it works or fails. Additionally running the application a different time that form is found and the iul_dochandle is returned correctly.

PBhtgetform() is in PBnote60.dll. This is a protected and private function.

Lotus Notes DB does not appears to be corrupt as it works fine in Lotus Notes and only fails randomly from within PB.



CR:190383
CR Number:   190383
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
20 Jul 2001 Fixed
Description
7.0 Regression. Press TAB key to tab off any treeview item in development or runtime and the system beeps.
A sound beep is triggered when TAB out of the treeview control.
The behaviour is annoying for data-entry end-users because a sound beep is an audible signal to signify possible 'error' made and should not be signalling that the user has lost focus of the treeview and is now onto the next control on the window object.
Workaround Description
 None. There is no powerscript or property which can disable the sound emitted.



CR:190437
CR Number:   190437
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
When a window has 1 control with a tab order, you cannot
capture the tab key. The other event fires sporadic. PB will capture other keys
but not the keytab!.



CR:190448
CR Number:   190448
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
09 Mar 1999 Third Party Problem
Description
Problem with the Common Dialog OCX from Microsoft. With 7.0 I get this error during migration, and with any attempt to regenerate:
Object: w_main
ole_1 Class Declaration
(0016): Warning C0088: Duplicate property name: binarykey

When I attempt to run the app, I get: PB70 caused an invalid page fault in module PBVM70.DLL at 0137:1138c618.

PER DEVELOPMENT:
This seems to be Microsoft support DLL version specific:
COMCTL32.DLL - 4.72.3609.2000 - everything works fine
but
COMCTL32.DLL - 4.72.3611.1900 - we get "invalid property" on the control's property page but NO GPF.
My test case: PB7 bld 5019, NT4.0 SP4

My current theory is that the binary stream (the IPersistStorage) from the OLD version
of the control is incompatible with the NEW version of the control (which breaks the rules).
Everything works fine if the OLD control is deleted from the window and a NEW control is added.
Doesn't look like there's anything I can do when the control changes its binary data stream format.
WORKAROUND:
Delete the OLD control and add the new one.



CR:190514
CR Number:   190514
Product Name:   PB Enterprise
Product Component:   Menus - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
06 Apr 2001 Not reproducible with latest version of the product available as of Resolution Date
Description
Simple genapp application that was created in build 444 through 555 and simply trying to do File=> Close on the already open sheet results in an illegal page fault in pbvm60.dll in all builds tested through 555. This does not appear to be a problem in either PB 5.0 or PB 7.0. Furthermore when I create, or do a full rebuild of the genapp in PB 6.0 GA, it does not fail when run in any build, until I do a full rebuild in build 444 or above.



CR:190533
CR Number:   190533
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Feb 1999 Not a Bug
Description
PB7.0 Beta: Right clicking off container object no longer selects container obj.



CR:190545
CR Number:   190545
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
1032 19 Apr 1999 Fixed
Description
PB 7.0 Beta: Can't print out just the script for an event or function.



CR:190591
CR Number:   190591
Product Name:   PB Enterprise
Product Component:   DW SaveAs
Status:   Closed
OS:   Microsoft Windows 98
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Powerbuilder SaveAs "Excel5" format is broken for Croatian fonts. The error is reproduceable when the "saved-to-format-file" is opened in MS EXCEL, then font change to Croatian, then copy and paste operation.
Workaround Description
 Possible Workaround: Do the font conversion after the user has pasted the default(e.g.Arial) or other "English standard" font into the new worksheet. Do not convert current text/ worksheet to cp1250 before copy and
paste.



CR:190592
CR Number:   190592
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 15 Mar 1999 Fixed
Description
This is now fixed in 6.5 Build 580 and PB 7.0 Build 5027

CrossTabDialog() - Changing the order of the columns in the Values expression list will cause an Access Violation when you hit OK. Also happens in DW painter when previewing a crosstab dw and you click on the Design menu and click Crosstab... to get the same dialog window

PB 5.0.04 -> OK
PB 6.0.251 -> OK
PB 6.5.444 -> - (0xc0000005) 0x10b96cca
PB 6.5.555 -> - (0xc0000005) 0x1055f177

No workaround, fails from the dw painter in preview mode, using CrossTabDialog and also if using Modify()



CR:190593
CR Number:   190593
Product Name:   PB Enterprise
Product Component:   Migration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Customer would like to have a migration Information/Warning message when the handle function is called with parameter such as Datastore.



CR:190607
CR Number:   190607
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
When row > 1 , computed column not evaluated when the dw is a nested datawindow



CR:190614
CR Number:   190614
Product Name:   PB Enterprise
Product Component:   Machine Code Exe Creation
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Customer has an application which at times passes null values read from a table to a user object function that parses the string catatonating a name into first name, middle initial, last name and name suffix. Starting in PB 6.5 build 444 the machine code exe fails if any of the columns contain a null. The p-code exe still works fine and if the strings, including the nulls, are read into temp variables and then passed to the function for parsing the machine code exe also works fine.

Workaround: Use p-code or read into temp string variables prior to passing into function.



CR:190616
CR Number:   190616
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 EBF1 7003 29 Jul 1999 Fixed
Description
PB 7.0 Beta: Find expression using numeric columns leaks memory in a datawindow



CR:190639
CR Number:   190639
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:
Ability to open an object in the library painter without it being in your current library path.

In pb 7.0, you need to click on the application object and than click on the object you want to open.
Its a two step process. In pb 6.0/6.5, it was a one step process.



CR:190671
CR Number:   190671
Product Name:   PB Enterprise
Product Component:   GenApp
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Mar 2001 Fixed
Description
I should be able to explicitly place the registry key wherever I want not just under "HKEY_CURRENT_USER/Software/<Your Company Name>/appname.

Workaround:
You can do this after using the wizard by opening n_genapp_connectservice and modifying the function of_getconnectioninfo to have it point to wherever you want. The Wizard at this point is just meant to generate a typical situation.



CR:190675
CR Number:   190675
Product Name:   PB Enterprise
Product Component:   Language - Compiler
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 Jul 2000 Fixed
Description
Embedded SQL can cause Internal Script Overflow errors depending on the amount of errors there are in the SQL statements and the total length of all the statements.



CR:190748
CR Number:   190748
Product Name:   PB Enterprise
Product Component:   Menus - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
10 Feb 1999 Duplicate
Description
Regression: Menu are not redrawn correctly when menu attributes are changed



CR:190760
CR Number:   190760
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
RTL- In Script editor, cannot enter special characters at the left of RTL word



CR:190780
CR Number:   190780
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Mar 1999 Duplicate
Description
7.0 Beta: Application object test, data, and header properties do not show in dw



CR:190807
CR Number:   190807
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Feb 1999 Not a Bug
Description
If any rows are selected when a datawindow sort is done, after the sort, the rows selected befire the sort are still selected in addition to the first row.



CR:190911
CR Number:   190911
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 09 Apr 1999 Fixed
Description
Datawindow Rows To Disk option does not work



CR:190940
CR Number:   190940
Product Name:   PB Enterprise
Product Component:   DB ODBC
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC0 17 Mar 1999 Not a Bug
Description
Getting error when trying to pass an output parameter
back to pb using a stored procedure and the declare/fetch/execute.

Using odbc to connect to ms sql server. Using disablebind=1. Using
sqlsrv32.dll (version 3.60.0319). Works ok using ms native driver (though
using slightly different syntax.)

Getting error of:
Cursor is not open.

Used the following syntax:
DECLARE SP_DURATION PROCEDURE FOR dbo.pr_date_diff_prd
@var_date_1 = :ad_start,
@var_date_2 = :ad_end,
@rtn_diff_prd = :ls_duration
USING SQLCA;
Execute sp_duration;
FETCH SP_DURATION INTO :ad_start, :ad_end, :ls_duration;



CR:190992
CR Number:   190992
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   5.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 07 Jul 1999 Fixed
Description
Unable to call DefinedName() function on Formula One control version 5 and above.



CR:191002
CR Number:   191002
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1011 23 Sep 1999 Fixed
Description
The window icon no longer defaults to icon assigned to application in PowerBuilder 7.0. Prior versions of Powerbuilder always defaulted to the same icon as the application. This meant that in Win9x and NT platforms, the icon in the upper left of the title bar was the same as the application Icon and when minimized, the taskbar icon would also be the same as the application icon. In 7.0, this defaults to the windows default icon.

Problems may arise with MIGRATED applications. You have to explicitly set the window icon on the frame window in MDI or on every sheet in an SDI application to "AppIcon!".

There were several performance problems related to this change (window open performance) as well. Migrated applications would have a blank window icon as "" and PowerBuilder would search down the PBD path for the "" icon (which it would never find). The performance bug associated with this change in behavior is CR204779 fixed in 7.01ebf build 7014.



CR:191046
CR Number:   191046
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Dec 1999 Fixed
Description
When an nvo is deployed in jaguar as a service and
you're editing the nvo in pb when live editing is enabled, saving the object
will result in the following error message:
"save of object failed"



CR:191057
CR Number:   191057
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC2 5025 09 Mar 1999 Fixed
Description
When an nvo is deployed in jaguar and you're in pb editing
the nvo that has live editing enabled, saving the nvo several times,
will cause pb script to disappear in the nvo.



CR:191058
CR Number:   191058
Product Name:   PB Enterprise
Product Component:   Web.PB
Status:   Closed
OS:   Solaris 2.5.1
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 29 Mar 1999 Fixed
Description
When running the windu deamon of windu_registryd4x, the -d
parameter should allow redirection of output.

windu_registryd4x -vers2 -prog xxxxxxxxx -d /tmp -k



CR:191109
CR Number:   191109
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
The problem appears when the scenario is tab control, dropdownlistbox with Sorted property OFF, Border type-StyleShadowBox ;
The ddlb border type style -"StyleShadowBox" does not toggle off when the setting is changed.
The problem manifests only when ddlb is on tab control.
Workaround Description
 Change property settings for other attributes of the ddlb e.g. Visible, Width, x, y etc. and then change the borderstyle setting e.g. tab.tabpage.ddlb.y=..y + 0 ; However some properties are exempt from triggering this change for borderstyle e.g. Limit



CR:191135
CR Number:   191135
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
1011 18 Mar 1999 Not reproducible with latest version of the product available as of Resolution Date
Description
Beta 7.0(RC0): In the window painter, insert a control of type datawindow or uo of type datawindow. Change the properties of the datawindow control to have a vscrollbar and hscrollbar. The changes are not seen until you save the window, close it and reopen the window in the painter.



CR:191136
CR Number:   191136
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
If you move column(s) to different orders, and try to reset them to the original order, it does not work.

In a grid datawindow the original column order is 1,2,3,4, if you move the columns by clicking and dragging to the following order 4,1,2,3. If you try and reset the column order to 1,2,3,4, with the following powerscript:

dw_20145523.Object.col1.X=is_col1
dw_20145523.Object.col2.X=is_col2
dw_20145523.Object.col3.X=is_col3
dw_20145523.Object.col4.X=is_col4

It does not work, the columns get ordered 2,3,4,1. If you run the same code again the column order gets set back to the original 1,2,3,4



CR:191141
CR Number:   191141
Product Name:   PB Enterprise
Product Component:   Menu Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
5020 22 Feb 1999 Fixed
Description
In the menu Painter and you modify toolbar properties,
wysiwyg menu shows different results.

1. Can't close out of dropdown menu items.



CR:191142
CR Number:   191142
Product Name:   PB Enterprise
Product Component:   Menu Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
1240 16 Mar 2004 EOL'd version. Not to be Fixed.
Description
If you open more than 1 wysiwyg menu, the other wysiwyg menus don't
show the toolbar items.



CR:191143
CR Number:   191143
Product Name:   PB Enterprise
Product Component:   Menu Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
5020 22 Feb 1999 Fixed
Description
Selecting a dd menu item and scrolling thru the values
of toolbaritemindex and toolbaritemorder and then return to its original value
will change/rearrange the order of the toolbar icons.



CR:191144
CR Number:   191144
Product Name:   PB Enterprise
Product Component:   Menu Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
5020 22 Feb 1999 Fixed
Description
The toolbar icons that show up in the wysiwyg menu and when you run the
app show different icons. If the toolbar icon shows a toolbarorder of zero, the icon
appears on the wysiwyg menu, but does not show up when running app.



CR:191146
CR Number:   191146
Product Name:   PB Enterprise
Product Component:   Menu Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
5020 22 Feb 1999 Fixed
Description
Attaching a menu to a mdi window and than viewing the
menu thru the wysiwyg menu, changes the appearance.



CR:191151
CR Number:   191151
Product Name:   PB Enterprise
Product Component:   Generators
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
PB 7.0 Beta: COM/MTS generator does not put helpstring in IDL file.



CR:191176
CR Number:   191176
Product Name:   PB Enterprise
Product Component:   UO - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 25 Jun 1999 Fixed
Description
Regression/ Change of Behavior in PB 6.0 GA through PB 6.5 build 560 on an IsValid() that is resulting in an illegal page fault in PBVM60.dll after the close of window with Dynamic Objects. The sample application is parsing syntax from a text file to create all dw's and all object on the window are user objects and/or created dynamically. Could not reproduce illegal page fault in simple sample using standard PB objects.



CR:191198
CR Number:   191198
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 569 10 Mar 1999 Fixed
Description
Printing a datawindow in 6.5 sends 50 times as much data to printer as 5.0.04.



CR:191231
CR Number:   191231
Product Name:   PB Enterprise
Product Component:   Menu Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Provide the stock picture icons that are special enumerated images in the menu painter as bmps so that they can be used on a window picture button.



CR:191232
CR Number:   191232
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1004 04 Mar 1999 Fixed
Description
This is a regression bug (worked in PB5, broken in PB6 and 7).
The expression ((333 -30 -61.5) /840)* 100 in a computed field produces an incorrect result of 27.7 when format is 0.0 instead of the expected result of 27.8
Other expressions tested with produce the desired results with format 0.0 : E.g. 2/3 expression calculates result as 0.7 ;
Workaround Description
 Workaround is using the Round function and specify number of decimal places:
Computed Field:
Round(((333-30-61.5)/840)*100 , 1) will give expected result 28.8 instead of 27.7 with format 0.0



CR:191247
CR Number:   191247
Product Name:   PB Enterprise
Product Component:   Language - Compiler
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   5.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
PB5.x and 6.x (all OS): regression from PB4.x: Cannot map a sle user event to pbm_settext without getting compilation errors at regeneration of window or exe creation.

steps to reproduce:
on a window, add a sle.
With sle selected, go to Declare> User events, and add a new user event mapped to: pbm_settext
exit and save window.
From the library painter, right click on the window, Regenerate
=> get following compilation warning:
Library: d:\mypbl5\mywindow.pbl
Object: w_mywindow
sle_1 Class Declaration
(0002): Information C0148: The identifier 'text' conflicts with an existing property with this name. The new definition of 'text' will take precedence and the prior value will be ignored until this version of 'text' goes out of scope



CR:191283
CR Number:   191283
Product Name:   PB Enterprise
Product Component:   ORCA
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 607 31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
ORCA regeneration produces an object that gpfs under some conditions when that object contains embedded SQL. Same object regenerated through the library painter works fine. Size of regenerated object is also smaller when regenerated with ORCA than through the library painter. A general CR (173731) for this problem was submitted previously and the resolution was that the size of resulting object was not an issue.



CR:191287
CR Number:   191287
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
Beta 7.0: When running application, a page fault will occur in PBVM70.DLL@0137:1152dcd4 if assigning a .jpg file that has been renamed from a .gif file.



CR:191303
CR Number:   191303
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 1999 Duplicate
Description
This may be a duplicate of CR 166871 which has been determined to not be a bug.

Composite report with two reports where the second report has 'New Page on Group Break" checked. Neither report in the composite has 'Start on New Page' checked.

In PB 5.0.02 and 5.0.03 the first report in the composite displays then the first group from the second report is directly under the first report. The second group then starts on the next page.

In PB 5.0.04, 6.0, 6.5 through build 560 andPB 7.0 through build 5020 the first report in the composite displays and then the second report immediately breaks to the next page.

Workaround: Place composite report into another composite report and the report appears the same as in PB 5.0.02 and PB 5.0.03.



CR:191314
CR Number:   191314
Product Name:   PB Enterprise
Product Component:   Application Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1002 06 Apr 1999 Fixed
Description
Typo in main menu of Application Painter.
Under the "View" menu in PowerBuilder, there is a typo. It should say "Non-Visual Object List" rather than "Non-Viusal Object List".


Fixed in 8.0 only.



CR:191335
CR Number:   191335
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
The font color of a drop down list box column in a datawindow does change even user specify a font color in the property -> Font window. The font color would always be widnow's default color.



CR:191349
CR Number:   191349
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 EBF1 7003 29 Jul 1999 Fixed
Description
Datawindow limit on the number of nested reports in a dw with two groupings.



CR:191351
CR Number:   191351
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 6000 31 Oct 2002 Fixed
Description
When connected to Oracle8, if the Oracle server is brought down, a subsequent attempt to call a stored procedure causes a GPF.



CR:191357
CR Number:   191357
Product Name:   PB Enterprise
Product Component:   Help
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   5.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Mar 1999 Fixed
Description
Help on WindowType attribute isn't correct (can't dynamicly modify it as written).
In WindowType topic from online help we can read :
The following line sets the type of a window.
w_2.WindowType = Response!

- In reallity this can't work and compilator raises error "(0001): Error C0143: A readonly property may only be modified in an event or function in its parent class" when trying to compile such a line from a button put on the window.
- compilator raises error "(0001): Error C0143: A systemwrite property may only be modified in an event or function in its parent class" when trying to compile such a line from the window itself.
- Help should specify that it's a read-only attribute



CR:191359
CR Number:   191359
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Mar 1999 Duplicate
Description
Creating a com pb object and than importing the object
as an activex/tlb in jaguar fails for the first method. If the pb object has more
than 1 method, the import fails on only the first method. The following error
appears in Jaguar when importing the com object:

"The import completed but not all methods could be imported.
See Jaguar Manager console for details."

The jagman.log file has the following entry:
AX Importer Warning: f_a was not imported.
com.sybase.jaguar.util.JException: Lookup failed for list of operations:
Component testing/PB70_uo_tjaguar_1 does not exist

The methods that do get imported into jaguar work ok when called from PB 7.0.



CR:191372
CR Number:   191372
Product Name:   PB Enterprise
Product Component:   Application Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Add a browse button/feature to the additional properties/variable types section for the application object to select objects for the "SQLCA", "SQLDA", "SQLSA", "Error" and "Message" objects.



CR:191382
CR Number:   191382
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Apr 1999 Fixed
Description
dwo_empsalary = dw_1.Object.emp_salary
FOR li_cnt = 1 to 100
!!!!!!!!!!!!! li_data = dwo_empsalary[li_cnt]
.. // Code to process data value
NEXT
Must be changed into
li_data = dwo_empsalary.Primary[li_cnt]



CR:191388
CR Number:   191388
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Feb 1999 Duplicate
Description
PB 7.0 Beta: Autoscript dropdown goes below bottom of window and out of range



CR:191408
CR Number:   191408
Product Name:   PB Enterprise
Product Component:   DB ODBC
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Mar 1999 Presently Not Targeted For Any Future Release Of This Product
Description
The client needs to deploy 16 bit PowerBuilder 6.5 executables onto WIN 95 or NT 4. He uses these in conjunction with some other 16 bit apps on the 32 bit platforms.

Application 1:

This application connects and disconnects from a 16 bit SQLAnywhere 5.5.x database.

Application 2:

This application just opens and closes a main window.

If app 1 is run on its own, the user can connect and disconnect as many times as he/she wants.
If app 2 is run alongside with app 1, the user can still connect and disconnect as many times as he/she wants.
If app 2 is stopped, if the user tries to connect with app 1, he will get the following GPF:

Application Error
PBSTB60 caused a General Protection Fault in Module PBODB60W.DLL at 000A : 09D5

Choose close. PBSTB60 will close.

I have reproduced the problem with build 560 of PowerBuilder 6.5, it also fails with all previous builds.

NOTE: The above scenario works on WIN 3.x and also with 32 bit deployed executables.

Per Development:
Not to be fixed.
There are no plans for Development to address 16-bit issues on 32-bit platforms. These types of issues, as stated in the Product Management Tech Doc below:

47860 PowerBuilder 6.5: 16-Bit Applications on 32-bit Platform
http://techinfo.sybase.com/css/techinfo.nsf/DocID/ID=47860

"Since the PowerBuilder development environment can produce applications for 16 or 32-bit native deployment on Microsoft Windows, the applications must be deployed to the corresponding Windows platform. 16-bit applications are only supported on Microsoft Windows 3.x."



CR:191432
CR Number:   191432
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
SetSort() returning returns 1 if a wrong column name is specified in the format (sortlist)
Only the column in front of the wrong column name are set to sort.
Workaround: use describe function to check if a column name is valid or invalid



CR:191433
CR Number:   191433
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   5.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
PICTURE LIST BOX : Bad display of strings containing tabs
Tab stops do not work in picturelistbox. Tabs are shown as un-printable chars.



CR:191442
CR Number:   191442
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 596 23 Jul 1999 Fixed
Description
A composite datawindow report may print an extart blank page at the end of the report.

Workaround Per Development:
The bug was a formula that was doubling of the space to the left of the nested report, during printing calculations, making the DW Engine think there were 2 horizontal pages.

So, a workaround in 6.5 would be to keep the nests against the left side of the primary report -- if information has to be indented, indent it within the nest.

I also noticed that the bug was exaggerated when the nested DWs had smaller units of measure than the primary DW. I had as many as 10 empty horizontal pages coming out. Therefore, a side-bar for 6.5 would be to make sure the nested DWs have the same units-of-measure as the primary DW.



CR:191443
CR Number:   191443
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Mar 1999 Fixed
Description
The Online Help file does not indicate how one can dynamically assign tabpage properties in script. Since the tabpage is inherited from userobject, properties such as 'picturename' are available during runtime, but you wouldn't know if from the docs.



CR:191444
CR Number:   191444
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Customer would like the edit style for radiobutton and checkbox to have the Required checkbox property.



CR:191453
CR Number:   191453
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1009 13 Apr 1999 Fixed
Description
PowerBuilder GPFs if you insert one or more rows in print preview mode (into an empty dw) and then scroll to the previous page

Workaround: don't insert new rows in previewmode. You can switch between preview and non preview mode when you have to insert rows into a new dw without data like
dw_1.object.datawindow.print.preview = "no"
dw_1.insertrow()
dw_1.object.datawindow.print.preview = "yes"



CR:191458
CR Number:   191458
Product Name:   PB Enterprise
Product Component:   DW Graph
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1007 13 Apr 1999 Fixed
Description
The value axis may be incorrect when value is a time. The groups are being calculated (in four hour increments) incorrectly because the maximum value for the axis is based on rounding the maximum value down to the next group increment instead of up as it should be. For example if your maximum data value was 22:23:11, the maximum axis value would be 20:00:00 instead of 24:00:00 as it should be.,



CR:191469
CR Number:   191469
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Open
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request: Implement the property SizeMode for the DataWindow Object. This new property was implemented in 7.0 for an OLE control on a Window. This would be a nice to have in the DataWindow Painter for OLE DB columns. Currently all OLE DB columns have a default of Stretch! (and there is no way to change this).



CR:191482
CR Number:   191482
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 EBF1 6004 15 Apr 1999 Fixed
Description
Datawindow control size to be the same height of the detail band - using RowsDiscard() function will cause the control be blank out.



CR:191483
CR Number:   191483
Product Name:   PB Enterprise
Product Component:   DW Graph
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
09 Apr 1999 Duplicate
Description
A bar graph coneverted from PB 6.5 to PB 7 no longer shows the bars.



CR:191552
CR Number:   191552
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
24 Sep 1999 Fixed
Description
When creating a Jaguar Service component from PowerBuilder, the component attributes may not default correctly. The component attributes should be:

Concurrency -> checked
Bind Thread -> unchecked
Pooling -> unchecked
Sharing -> checked
Workaround Description
 After creating a Jaguar service component in PowerBuilder, set the component properties in the Jaguar manager as follows:

Concurrency -> checked
Bind Thread -> unchecked
Pooling -> unchecked
Sharing -> checked



CR:191555
CR Number:   191555
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 RC0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Apr 2001 Not a Bug
Description
Once you call a com object from pb, and then go back and try to
re-execute the (com) project, the following message appears in pb:

Linking object files for server failed! Error linking d:\xxxxxx See log file
d:\xxxxx\xxxx.log

If you close out pb, and recycle the jaguar server than go back into pb,
no problems. The execution of the project is ok.



CR:191566
CR Number:   191566
Product Name:   PB Enterprise
Product Component:   Windu/U
Status:   Closed
OS:   Solaris 2.5.1
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
The icons in the floating toolbar are not visible on Unix



CR:191571
CR Number:   191571
Product Name:   PB Enterprise
Product Component:   Inheritance
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 1 1275 11 Dec 2000 Fixed
Description
Beta 7.0: When you declare a CONSTANT instance variable on an object (window or uo), then inherit from that object, PowerBuilder allows you to change the value of that instance variable (even though it was declared as a constant in the ancestor) but that new value is not saved when you save the object.. When the instance variable is not declared as a constant, there is no problem.



CR:191572
CR Number:   191572
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
resizing detail band height to -2 or lower value causes GPF

W/A is to check the value and set to 0 if negative.



CR:191574
CR Number:   191574
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Aug 1999 Not a Bug
Description
Freeform : Clicked event from datawindow is fired when you click on the window

RESOLUTION:
Although the behavior changed between 5.04 and 6.0, this is not a bug. You should not issue a message box from a clicked event. The DW clicked event is issued from the buttondown part of the click, when the messagebox comes up, being modal it causes the edit control to have captured the mouse. Therefore, any subsequent click is routed to the edit control, no matter where the mouse pointer is.
The actual behavior change was in the runtime engine (PBVM) between 5.04 and 6.0. Dan further suggested that DWE ought to process the clicked event from the button up and this might prevent this condition. We may consider this in a future release but it would itself be a huge behavior change for DWE



CR:191577
CR Number:   191577
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 10165 26 Mar 2002 Fixed
Description
Filtering on Shared Datawindows may cause application to crash/GPF



CR:191579
CR Number:   191579
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
should be possible to get FirstRowOnPage before the page actually starts to print.
should be possible to set a range (say page 3 and 4) and then find the firstRowOnPage (FROP) before he prints so he can change things, then change page 4 based on FROP.

Fax Document 42041 ="Determining the Row Number of the Row at the Top of the Page about to Print (PB 4.0, 5.0)". It does seem to imply that one can obtain the row number of the first row before the page is actively in memory, BUT this is not possible.
string lsFirstRowOnPage
lsFirstRowOnPage = this.Describe("DataWindow.FirstRowOnPage")
Using the above code does not find the First Row On the Page about to print but instead, it finds the First Row on the Page that is currently in memory.



CR:191588
CR Number:   191588
Product Name:   PB Enterprise
Product Component:   Menus - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
reference the a mdi menu with dot notation is not possible, because shared frame menu reference is deleted by closing a sheet window.

Workaround: use parent instead of mdi frame name or better use the menuid to refer to menu.



CR:191594
CR Number:   191594
Product Name:   PB Enterprise
Product Component:   Structure Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
In the structure painter the column headers are not layered properly, e.g the VarableName Text in the column headers should be brought front as the Type Text.
bring the variable name to the front and the datatpe after the var name like in PB4, 5 and 6



CR:191639
CR Number:   191639
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
RTL - Need a right to left attribute for a computed field in a datawindow



CR:191641
CR Number:   191641
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1040 30 Mar 2000 Fixed
Description
GPF in PBDWE60.dll if sharedata is done between a DS and a DW and no rows are in the primary dataobject and the secondary is a Rich Text datawindow.

Workaround:
Insert a dummy row into the datastore before you share the data. See Script

lds = CREATE datastore
lds.dataobject = dw_richtext.dataobject
lds.setTransObject(SQLCA)

//Workaround start
ll_rows = lds.Retrieve(1)
IF ll_rows = 0 Then lds.InsertRow(0)
// workaround end

lds.shareData(dw_richtext)



CR:191656
CR Number:   191656
Product Name:   PB Enterprise
Product Component:   MAPI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 576 05 Apr 1999 Fixed
Description
SmartHeap Library : MEM_BAD_POINTER After calling MailLogon function



CR:191666
CR Number:   191666
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 May 2003 Not a Bug
Description
Setsort sometimes on columnname synax with joined table and works when using column id syntax.

Workaround: Use column id syntax instead of the columnname syntax



CR:191674
CR Number:   191674
Product Name:   PB Enterprise
Product Component:   File Editor
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 RC1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1006 06 Apr 1999 Fixed
Description
The file editor in PB6 shows the line and column that you are on. This is missing in the PB7 editor. It's a very useful feature, please don't remove it.



CR:191677
CR Number:   191677
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 EBF1 6004 30 Jun 1999 Fixed
Description
Expression in Y property of a computed field is using a wrong unit

WORKAROUND:
Create a global function (f_utp) that returns an integer and that has a integer parameter. The script for this function is :
return UnitsToPixels(ai_yParam, YUnitsToPixels!)

Then use your global function in your expression to return the y coordinates :
if( len(string(cf_1))>4,f_utp(10), if( len(string(cf_2))>4,f_utp(10), if( len(string(cf_3))>4,f_utp(10), if( len(string(cf_4))>4,f_utp(10), if( len(string(cf_5))>4,f_utp(10),f_utp(84))))))

The problem of this workarouond is that there's a problem when you print your datawindow...



CR:191690
CR Number:   191690
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   5.0.04
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 Jul 2000 Not a Bug
Description
Changing a DW Column object's password property to 'yes' at runtime allows the pasword to be seen when focus is removed from the object.



CR:191696
CR Number:   191696
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Mar 2000 Fixed
Description
In pb design mode, dw painter, for a rich text dw, there is only a default choice for paper size and source on the dw properties sheet, print specification tab. In pb 5.0, could you see wide number of sizes and sources.





--------------------------------------华丽的分割线-------------------------------------------------------------------------

Sybase SQL Anywhere数据库恢复工具ReadASADB:

之前就已经研发成功了能够从Sybase SQL Anywhere的DB文件中恢复数据的工具: ReadASADB。
此工具支持ASA v5.0, v6.0, v7.0, v8.0, v9.0, v10.0, v11.0, v12.0, v16.0, v17.0等版本。
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具。
恢复Sybase SQL Anywhere的工具在国内处于领先水平。

Sybase SQL Anywhere数据库恢复工具ReadASADB功能
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具
  1. 适用于所有的SQL Anywhere版本    包括:5.x,6.x,7.x,8.x,9.x,10.x,11.x,12.x,16.x,17.x
  2. 适用于所有的UltraLite版本
  3. 能够恢复出来表结构和数据
  4. 能够恢复自定义数据类型
  5. 能够恢复存储过程等对象的语法
  6. 能够导出到目标数据库
  7. 能够导出到SQL文件并生成导入脚本
  8. 支持多种字符集,包括:cp850、cp936、gb18030、utf8等
  9. 能够恢复未加密或者简单加密类型的数据
  10. 简单易用
  11. 限制:不支持AES加密的数据文件
请参考:研发成功了从Sybase SQL Anywhere的DB文件上恢复数据的工具
            SQL Anywhere数据库非常规恢复工具ReadASADB使用介绍

Sybase SQL Anywhere数据库恢复工具ReadASADB适用场景

各种误操作:

  1. 误截断表(truncate table)
  2. 误删除表(drop table)
  3. 错误的where条件误删数据
  4. 误删除db或log文件
  5. 误删除表中的字段

Sybase SQL Anywhere数据库恢复工具ReadASADB的应用场景:

1.因为物理磁盘故障、操作系统、系统软件方面或者掉电等等原因导致的Sybase SQL Anywhere数据库无法打开的情况;
2.误操作,包括truncate table,drop table,不正确的where条件导致的误删除等;
Sybase SQL Anywhere无法打开时,比较常见的错误是:Assertion failed。
如:
1、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Checkpoint log: invalid bitmap page -- transaction rolled back
2、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Page number on page does not match page requested -- transaction rolled back
3、Internal database error *** ERROR *** Assertion failed:200502 (9.0.2.2451) Checksum failure on page 23 -- transaction rolled back
4、File is shorter than expected
5、Internal database error *** ERROR *** Assertion failed: 201116 Invalid free list index page found while processing checkpoint log -- transaction rolled back
6、*** ERROR *** Assertion failed: 51901 Page for requested record not a table page or record not present on page
7、*** ERROR *** Assertion failed: 201417 (7.0.4.3541) Invalid count or free space offset detected on a table page
8、Internal database error *** ERROR *** Assertion failed: 201425 (8.0.3.5594) Invalid count or free space offset detected on a free list page -- transaction rolled back.
9、Internal database error *** ERROR *** Assertion failed: 100702 (8.0.1.2600) Unable to modify indexes for a row referenced in rollback log -- transaction rolled back


-------------------------------------------------------------------------------------------

Sybase ASE数据库恢复工具READSYBDEVICE:

一个不依赖数据库管理系统、直接从Sybase数据库设备文件上提取数据的业内领先的恢复工具!
能够从损坏的Sybase ASE设备文件(.dat)上提取数据的非常规恢复工具。

Sybase ASE数据库恢复工具READSYBDEVICE的主要功能:

  1. 被勒索病毒加密数据文件及备份文件情况下的恢复;
  2. 系统崩溃只剩下数据文件的情况下的恢复,甚至数据库文件不存在而只有损坏的备份文件情况下的恢复;
  3. 因断电、硬盘坏道等造成数据库文件损坏情况下的恢复;
  4. delete数据恢复、误update数据恢复、误删除表(drop)恢复、误truncate表恢复 等;
  5. 各种Sybase内部系统表损坏、索引错误的修复;
  6. master数据库损坏而无法正常运行情况下的恢复;
  7. Sybase数据库被标记为可疑,不可用等情况的恢复;
  8. Sybase数据库中数据文件内部出现坏块情况下的恢复;
  9. Sybase数据库无数据文件但有日志文件的情况下的恢复;
  10. Sybase数据库只有数据文件无任何日志文件的情况下的恢复;
  11. Sybase数据文件被误删除情况下的碎片提取恢复;
  12. 磁盘阵列上的Sybase数据库被误格式化情况下的数据库恢复;
  13. 数据库sysobjects等系统表损坏无法正常应用情况下的恢复;
  14. Sybase数据库还原数据库出现失败情况下的恢复;
  15. Sybase数据库只剩下损坏的备份文件情况下的恢复。

Sybase ASE数据库恢复工具READSYBDEVICE支持的版本:

Sybase ASE 11.0.x,11.5.x,11.9.x,12.0.x,12.5.x,15.0.x,15.5.x,15.7.x,16.0.x


-------------------------------------------------------------------------------------------

SQL Server数据库恢复工具SQLRescue:

一个不依赖数据库管理系统、直接从SQL Server数据库文件上提取数据的业内领先的恢复工具!
能够从损坏的SQL Server数据库文件(.mdf)上提取数据的非常规恢复工具。

SQL Server数据库恢复工具SQLRescue的主要功能:

  1. 系统崩溃只剩下数据文件的情况下的恢复,即无日志文件或者日志文件损坏情况下的恢复;
  2. 断电导致数据库文件损坏情况下的恢复;
  3. 硬盘坏道造成数据库损坏情况下的恢复;
  4. 数据文件内部存在坏页情况下的恢复;
  5. 企业管理器误删除数据表记录,管理软件误删除数据表记录的恢复;
  6. 并闩锁错误、格式化、误删除后导致软件不能使用的情况;
  7. 无法读取并闩锁页sysindexes失败情况下的修复;
  8. 数据文件被误删除情况下的碎片提取恢复;
  9. 系统表损坏、索引错误、误删除数据库表、删除记录的数据找回;
  10. master数据库损坏而无法正常运行情况下的恢复;
  11. 数据文件无法附加情况下的数据恢复;
  12. 数据库被标记为可疑,质疑,不可用等情况的恢复;
  13. 数据库sysobjects等系统表损坏情况下的恢复;
  14. 数据被误(drop、delete、truncate)删除表数据的恢复,误update后的数据恢复等;
  15. 还原时报一致性错误,错误823等情况下的数据恢复,各种错误提示的数据库文件修复;
  16. 数据库被误格式化等情况下的数据库恢复;
  17. 日志收缩造成数据库损坏情况下的恢复;
  18. 仅剩损坏的备份文件情况下的恢复。

SQL Server数据库恢复工具SQLRescue技术特点:

只要SQL Server数据库的数据文件存在,我们就有办法帮您从数据文件中找回重要数据。
  1. 从数据文件中直接恢复数据
  2. 不能附加时直接恢复数据并生成新的数据库
  3. 系统表损坏的数据库修复
  4. 快速修复SQL 823错误、连接中断错误

SQL Server数据库恢复工具SQLRescue支持的版本:

Microsoft SQL Server 7.0, 2000, 2005, 2008, 2008R2, 2012, 2014, 2016, 2017,2019。
+-------------------------------------华丽的分割线-------------------------------------------------------------------------