提供7*24专业Sybase数据库远程及现场技术支持,Sybase ASE及Sybase SQL Anywhere数据库修复服务,
请联系电话: (微信),QQ: 289965371!
We supply technical support for Sybase ASE and Sybase SQL Anywhere, also have many years of experience in recovering data from damanged Sybase devices.
Please contact us:
Phone:
Wechat: 13811580958
QQ: 289965371 联系我们获取数据库技术支持!
Email: 289965371@qq.com
扫描下方微信,联系我们:
扫描雨翰数据恢复官方微信获取专业数据库恢复服务

 

随着Sybase被完全整合到SAP下,Sybase原来的支持网站被SAP Support Portal取代。
只有购买了SAP服务的用户才能使用账号登录SAP Support Portal进行介质下载、补丁升级、报Incident等。
考虑到Sybase数据库的初学者或者没有购买原厂服务的Sybase客户情况,现提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息。
在SAP Support Portal网站或者google上搜索Targeted CR List for ASE,可以看到针对不同版本的CR(CR表示Change Request)简单描述信息列表。
需要注意的是:Targeted CR List for ASE列出的CR虽然绝大多数是BUG,但有一些是更改需求。
以下提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息!

如有问题,请联系我!

QQ :289965371 联系我们获取数据库技术支持!
Email:
不仅仅包括BUG的详细描述信息,还包括首次报告BUG的平台、数据库版本以及BUG修复历史过程;有些BUG还提供了Workaround来临时解决该BUG带来问题。

 

CR:185458
CR Number:   185458
Product Name:   PB Enterprise
Product Component:   Browser
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Customer would like a progress meter displayed in the Object Browser for the Show Hierarchy command instead of the Hourglass that currently displays.



CR:185461
CR Number:   185461
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
From the Function list tab, you should be able to copy the function (name, arguments, and return value) to the clipboard on paste it into your script. When you right-click and choose Copy and copy a function, then go to your script, it doesn't allow you to paste. The Paste menu is disabled. I think it should work much like the object browser and allow you to copy and paste the function along with the arguments.



CR:185467
CR Number:   185467
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Add background color and text color properties to command buttons.

NOTE: Windows API probably does not support this, but sent in for review.



CR:185469
CR Number:   185469
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
The PictureButton Object inserts space on the top and left hand sides of button when using a BMP as enabled file name. No known workaround available. The BMP is a 16x16 Icon picture.
Customer has Enhancement Request that he have the option not to have any border showing around the picture on the button. He would like the picture to go right out to all sides of the button.



CR:185470
CR Number:   185470
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 548 16 Feb 1999 Fixed
Description
6.0 Regression: Datawindow exhausts user resources w ver & hor scroll & autosize
Workaround Description
 If possible, resize the datawindow to be wider so that the addition of a vertical scroll bar will not also cause the need of a horizontal scroll bar.



CR:185517
CR Number:   185517
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 14 Jan 1999 Fixed
Description
problem in sharing a DW which has retrieval arguments with a nested DW (a child in a nest). When a window containing a composite DW, and the nested DW's will be previewed and destroyed, the second preview of this nested DW causes a GPF.



CR:185520
CR Number:   185520
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC0 4008 18 Jan 1999 Fixed
Description
Beta 7.0: If a PB7 object function is overloaded, the global search dialog will take you to the first occurrance of that function, regardless of which occurrance of the function actual contains the matching search item.

In PB 7.0 with the new view interface, there is a view that is displayed for script/functions. When you double click on any one of the functions in the search result dialog, the function that is displayed appears to be the 'oldest' one. Meaning if you modified one of the functions, the modified function would show up last in the global search list window because it had a later date/time.



CR:185523
CR Number:   185523
Product Name:   PB Enterprise
Product Component:   TAPI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.01
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 May 2001 Presently Not Targeted For Any Future Release Of This Product
Description
Would like option to use datastores as well as datawindows with Library for Lotus Notes.



CR:185529
CR Number:   185529
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
06 Jan 1999 Not a Bug
Description
After changing the font for a datawindow from Arial 6 to Arial 8, a subesequent datawindow print inserts blank pages at the front of the output and truncates some of the data at the end.

Per Development:
Not a bug. The DW Engine has always had this internal rule that a row fits on a page unless extended by a nested report. This issue has a row with an AutoSizeHeight Text field, which is given a 32K character string, causing the text and the row to span several pages. The Engine was not written to handle these types of 'word processing' documents. The only way to correctly handle large texts, is to cut the text into single lines of text, and report these lines as individual rows within a report or nested report. This enables the Engine to do its 'row processing', as originally designed.



CR:185539
CR Number:   185539
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.3 02 Sep 2003 Fixed
Description
When open a datawindow and save it using "Save As", the comments are not saved to the new datawindow object. Notice the comment section is identical to the original datawindow's comments and has not saved the changes.
Workaround Description
 After SaveAs operation is done. In library painter, select desired datawindow, RMB click and enter comments.



CR:185580
CR Number:   185580
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 524 31 Dec 1998 Fixed
Description
Crosstabmax() expression gives incorrect results when row data is 0 or negitive.



CR:185615
CR Number:   185615
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Dec 1998 Not reproducible with latest version of the product available as of Resolution Date
Description
GPF when scrolling datawindow with no rows retrieved.
Two datawindows, one in query mode which feeds the second dw. If a query is entered which returns 0 rows, scrolling the second dw causes a gpf.
Workaround Description
 Before the retrieve statement on the master datawindow

dw_2.sharedataoff() <--- Add this line
dw_2.dataobject = dw_1.dataobject <--- Add this line

dw_1.retrieve ()



CR:185634
CR Number:   185634
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 15 Aug 2000 Fixed
Description
Resolution: This is not a bug and the documentation will be changed to correctly reflect the fact that the datawindow handles the retrieval argument as a double which can only support up to 15 digits of precision. not 18 as previously stated in the documentation.

When FormatArgsAsExp= 'No' decimal retrieval arguments of 17 or 18 digits (and 'sometimes' numbers of 16 digits) are converted to exponential notation - independent of database interface. These should not be converted according to PB Documentation. Decimal retrieval arguments over 18 digits should truncate at 18 digits and these are also converted to exponential notation.

The following is taken from PB 6.5 Online Help:
When FormatArgsAsExp= 'No'
PowerBuilder leaves the retrieval argument as a decimal and does not perform the default conversion to scientific notation if it exceeds 12 digits

If a retrieval argument of type decimal exceeds 18 digits and FormatArgsAsExp is set to No to prevent conversion to scientific notation, PowerBuilder truncates the retrieval argument value after 18 digits.



CR:185655
CR Number:   185655
Product Name:   PB Enterprise
Product Component:   DW Synchronization
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 18 Jan 1999 Fixed
Description
Temporary files ( DWExxx.tmp) generated and not removed when using GetFullState(),SetFullState()



CR:185753
CR Number:   185753
Product Name:   PB Enterprise
Product Component:   Function Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
20 Jan 1999 Fixed
Description
7.0 Beta 2: No way to back out (delete) an overridden object function.



CR:185754
CR Number:   185754
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Dec 1998 Not a Bug
7.0.00 01 Apr 1999 Fixed
Description
When trying to obtain a decimal number from the DynamicDescriptionArea using GetDynamicNumber PB 6.0/6.5 appears to be rounding numbers with 17 and 18 digits.

When this data is brought back into a datawindow and GetItemDecimal is used the rounding does not occur when the numebr has 17 or 18 digits..



CR:185770
CR Number:   185770
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Customer has a crosstab datawindow which spans multiple pages horizontally when it is printed. They would like to have the Header carry over to all pages horizontally instead of just printing on each new verticle page.



CR:185812
CR Number:   185812
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Dec 1998 Not reproducible with latest version of the product available as of Resolution Date
Description
Attempt to create a proxy for the SVUCPPBookstore component. Package is installed using an autoextractible file, containing c++ components.
When trying to generate a proxy, it failed without any error message and proxy is not created.
Workaround Description
 1. Manually recreate your component => an IDL interface is then generated
2. OR deploy component using import/export options from jaguar manager (which is the way you should deploy)



CR:185832
CR Number:   185832
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
5004 27 Jan 1999 Not reproducible with latest version of the product available as of Resolution Date
Description
7.0 Beta: Using the Library painter to set an application as current fails.
Workaround Description
 Use menu selection File -> Select Application to set a new application if the library list is not defined yet.



CR:185842
CR Number:   185842
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Jan 1999 Fixed
Description
Beta 7.0 DW painter: Edit->Select->xxx does not display multi-select properties.
Workaround Description
 Select objects on the datawindow visually.



CR:185880
CR Number:   185880
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Fixed
Description
Regression/Change in behavior when querymode is "yes" in datawindow starting in build 482. Tested through build 515 with same changed results. PB 5.0.04 and PB 6.0/6.5 through build 444 work as expected.

With PB 5.0.04 and PB 6.0/6.5 through build 444 when querymode was turned on and a Wherecriteria for a column was entered it was not necessary to use either an accepttext () or change the focus to a different column in order for the retrieve to use this criteria.

Workaround: Placing an Accepttext() right before the retrieve allows the criteria entered to be applied to the Where clause.



CR:185919
CR Number:   185919
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Previewing a DW with retrieval argument (for example datatype date). Cst like to be able to test a DW with a NULL value as retrieval argument in the DW Preview.



CR:185970
CR Number:   185970
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Setting the desktop color scheme a specific way (specified below) causes the checkmark to be invisible on a datawindow column of checkbox style. Using a plain checkbox control on a window works okay. Using Control panel, modify your desktop appearance to be Windows standard and click the Apply button. Then choose the item "Message Box" from the Item ddlb (still in the Appearance tab of the display properties dialog) and change the Font Color to brown, or purplish on NT (the second row, second column of the color chooser ddlb, directly under the black square) and click okay to save that as your desktop settings. Preview any datawindow with a checkbox column. All the checkboxes appear to be unchecked, regardless of the data, and if you run with plain Windows Standard colors without modifying the color for Message Box, they may actually be checked. Clicking on them does not change the appearance, i.e., you cannot click them "on", they remain "off". If you add a checkbox control to the window (i.e., not a datawindow column) then the problem does not occur. This problem was introduced with Powerbuilder 6.0.



CR:186026
CR Number:   186026
Product Name:   PB Enterprise
Product Component:   Generators
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 527 31 Oct 2002 Fixed
Description
Array of string passed to a COM server gpf PB



CR:186027
CR Number:   186027
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Ct wants to be able to have several series and only use some of them in different categories. Now he has to include them all in all categorys with value set to 0. This gives huge gaps between the categories.
What they want is to 'Slide left' the seriesso that they don't have a gap between them.



CR:186028
CR Number:   186028
Product Name:   PB Enterprise
Product Component:   DPB
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Distributed server application GPFs or hangs in tasklist after the clients are disconected from the erver side and closing the window.
close event of the window will be triggered but the application will not be closed.



CR:186032
CR Number:   186032
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
This problem was reported in PFC function pfc_n_cst_dwsrv_querymode.of_load(). This function uses ImportFile() to load a query saved by of_save.
In a DW in query mode , if you have saved a criteria on a numeric column for ex. 'and >= 999', you cannot load it because Importfile() produces an Itemerror 'specified criteria in invalid'.



CR:186040
CR Number:   186040
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.x Catalina 1049 29 Mar 2000 Fixed
Description
grid dw with a computed field, where the taborder is set to 0 or protect propter is set to 1 dynamically jumps 2 rows when you press
the enter key.



CR:186136
CR Number:   186136
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   Solaris 2.5.1
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 05 Mar 1999 Fixed
Description
When a date field that has a edit mask of mm/dd/yyyy or dd/mmm/yyyy on a column and you
save the dw to a psr report that is than ported to wintel and viewed either in the report painter or a browser, the year
in the date field is garbage.

If you save the data to the dw and than port the dw object to wintel and than save the psr
on wintel, than it works ok.



CR:186174
CR Number:   186174
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC 4008 04 Jan 1999 Fixed
Description
Beta 7.0: Library painter does not refresh to show a project that was created with the application wizard. You need to do a View-->Refresh to get it to show. When you create a project not using the wizard and save it the library list does refresh automatically



CR:186179
CR Number:   186179
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Dec 1998 Presently Not Targeted For Any Future Release Of This Product
Description
User can check-out an object if an object that it depends on does not exist using the PB SCC version control interface.



CR:186237
CR Number:   186237
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Dec 1998 Fixed
Description
Beta 7.0: Creating and adding a new application object to an existing pbl causes an error: "Could not open application <app obj name> in <pbl name>"



CR:186240
CR Number:   186240
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   5.0.04
Fixed Version Build Resolution Date Closure Code (If Appropriate)
5.0.04 28 Jan 1999 Fixed
Description
In 5.0.04 a Richtext style datawindow does not print when using a Windows print job with PrintDataWindow().
The print job just sits in the queue and is never printed. Print() works fine and 5.0.03 worked OK
Workaround Description
 Use dw_1.Print () instead.



CR:186312
CR Number:   186312
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
8.0 Beta 1 11 May 2000 Fixed
Description
Scrolltorow or using arrow keys in a dw with a return 1 in rowfocuschanging still scrolls to the target row, even though the
current row does not change.



CR:186416
CR Number:   186416
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Dec 1998 Fixed
Description
Beta 7.0: When defining an editmask mask for a datawindow character column, changes are not saved when using File-->Save or the Save button on the toolbar. Changes ARE saved when you close the object without saving and then click "yes" when prompted to save.



CR:186441
CR Number:   186441
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Dec 1998 Fixed
Description
GPF (divide by zero) if dw radio button edit style columns across set to 0



CR:186443
CR Number:   186443
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Dec 1998 Fixed
Description
Beta 7.0: Character column on datawindow, has an edit style of type EditMask and mask with 12 x's. Save the datawindow by closing it and clicking yes when prompted. Re-open the same datawindow, add another x to the edit mask for the column. When you try to close and save the datawindow a page fault will occur:

Build 2227: pbvm70.dll@0137:11ce9ad6
Build 3259: pbvm70.dll@0137:11529e46



CR:186464
CR Number:   186464
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Dec 1998 Fixed
Description
7.0 Beta: Change columns across in a radio button edit style column, save the dw. Reopen the same dw, the columns across reverts back to 1.



CR:186514
CR Number:   186514
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 04 Jan 1999 Fixed
Description
When using getfullstate() and setfullstate() with the a crosstab aand then crosstabdialogue() the application immediately gets Out of Memory error.



CR:186592
CR Number:   186592
Product Name:   PB Enterprise
Product Component:   DB Sybase System
Status:   Closed
OS:   Solaris 2.5.1
Original Version:   5.0.04
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Connecting to Open Client 10.0.04 thru Powerbuilder doesn't work. Can't locate ebf7042. Applied ebf8050 and same problem.
EBF8050 is the y2k compliant version.

Workaround is to use OpenClient 11.1. This version is threadsafe.



CR:186627
CR Number:   186627
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
When printing > 1 copies of a datawindow with DUPLEX printing set on AND with COLLATE COPIES set on, if there are an uneven number of pages (ie side 2 of last page of each batch should be blank) then the first page of the second batch will print on the back of the last page of the previous batch when it should take a new page.



CR:186669
CR Number:   186669
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC 4010 28 Dec 1998 Fixed
Description
PB 7.0 Beta 2 through build 3259. When in the libarary painter list view the size of the object is left aligned not right aligned as a number usually is.



CR:186678
CR Number:   186678
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC0 4025 29 Jan 1999 Fixed
Description
Parentwindow.GetActiveSheet() returns a valid handle to an MDI frame when used in a sheet menu in 6.x, but does not in 7.0



CR:186729
CR Number:   186729
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 533 29 Jan 1999 Fixed
Description
Enhancement Request: Add OptSelectBlob DBParm for MS SQL Server



CR:186732
CR Number:   186732
Product Name:   PB Enterprise
Product Component:   DW Graph
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
06 Jan 1999 Duplicate
Description
when you set autoscale off. maximumvalue = 1000 and scaletype = 10 the axis run into a rounding issue. It becomes float values but it should be integer values



CR:186829
CR Number:   186829
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   AIX 4.1.5
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
When an external function has more than 8 arguments, the 9th passed is wrong. It doesn't depend on argument type.
for ex : FUNCTION long my_func9 (long il_1, long il_2, long il_3, long il_4, long il_5, long il_6, long il_7, long il_8, long l9) LIBRARY "libfunc9.a"

my_func9 just prints the datas received. Il_1 .... Il_9 are good but il_9 contains garbage.
There is no problem when the function is called by a C program.



CR:186846
CR Number:   186846
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   Solaris 2.5.1
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
19 Jan 1999 Third Party Problem
Description
After a connection to a DB Oracle 7.3.x and Sqlnet 2.3.x, PB crashes at the exit and produces a segmentation fault.
Workaround Description
 Install the Sqlnet in a different directory:
/work/app/oracle/product/2.3.4 for the sqlnet and tcpip modules and /work/app/oracle/product/7.3.4 for the server.
For the PB environment set the $ORACLE_HOME=/work/app/oracle/product/2.3.4



CR:186866
CR Number:   186866
Product Name:   PB Enterprise
Product Component:   DB ODBC
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 447 29 Dec 1998 Fixed
Description
Getting error "SQLSTATE = S1003 [Microsoft][ODBC Driver Manager] Program Type out of Range" in the database painter.

Microsoft has changed the types and lengths returned for some of their data types in their Microsoft SQL Server 7.0 version of their ODBC driver (3.70.x) and also in Microsoft Access drivers for version 4.0. As a result, PowerBuilder sometimes cannot find an internal mapping from PB data types to the ODBC data types of SQL Server.

If we don't have a valid data type before we are ready to do SQLBindCol, we now default to binding as type SQL_C_CHAR.

This should work fine in 6.5.1 build 620. It is broken in 6.5 build 444.



CR:186876
CR Number:   186876
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Customer trying to use Halt from SQLPreview event to prevent update from occurring. The correct way to handle this is to
return 1 from the SQLPrview event and then the update does not occur. Halt is documented to stop all processing, though, so
this is submitted as a bug. Either the update should not occur, or the documentation for Halt should be reviewed.



CR:186887
CR Number:   186887
Product Name:   PB Enterprise
Product Component:   Generators
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
wants to be able place the necessarry powerbuilder dlls in pblibrary directory setting in registry where the com generator points to. See below for more details.

ct. had multiple copies of pbvm60.dll one in sybase/shared and another in windows. After deleting one of thses files he was able to bring up the com generator
properly. He also uses web server which requires pbvm60.dll.
Enhancement request

place the necessarry powebuilder dlls in pblibrary directory setting in registry where the com generator points to. He thinks this will keep the development and
deployment environments from stepping on to each other. He also thinks this would be a little more intuthan the entry in the online help
help library search path

(If you choose to use the registry, the location of the PB COM server is written to a subkey called PBLibraryDirectory in the server's AppID key when the user
registers the server. The PB COM server uses this path to locate dependent libraries. The user can edit the PBLibraryDirectory subkey to deploy libraries in another
location on the deployment machine.



CR:186919
CR Number:   186919
Product Name:   PB Enterprise
Product Component:   Report Painter
Status:   Closed
OS:   Solaris 2.5.1
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 23 Apr 1999 Fixed
Description
When creating a psr report on wintel that has a where clause and than it's ported to unix, viewing the psr report in the report painter will cause Powerbuilder to crash with a bus error. Works ok in Powerbuilder 5.0.04 on Sun Solaris. Problem happens in PB 6.5 on Sun Solaris and HP-UX.



CR:186947
CR Number:   186947
Product Name:   PB Enterprise
Product Component:   DB Sybase System
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jan 1999 Not a Bug
Description
Powerbuilder produces random ODBC and System 11 (SYC) errors when doing several DataWindow retrieves and
if there is code in RetrieveRow event - errors:
Error 999 : Only cancel command is allowed when the rows are pending.
SYC also shows ct_close, ct_send and ct_connect errors



CR:186948
CR Number:   186948
Product Name:   PB Enterprise
Product Component:   Printing
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 Aug 1999 Third Party Problem
7.0.00 30 Mar 1999 Fixed
Description
PrintSend( job, "~027&l11H" ) works on Win NT 4.0, but not on win95.

RESOLUTION:
The PrintSend powerscript function is based on the Escape(...PASSTHRU...) Windows API function. The PASSTHRU escape is indicated as being obsolete and for Windows 16-bit only. It should not be used in Windows 32 bit. It is also an option for a printer driver to support this functionality. It is most likely that the printer driver simply does not support this functionality and it is reasonable that it does not. It is very much a hack to be sending codes directly to the printer, bypassing the print driver, in the middle of a print out.



CR:186950
CR Number:   186950
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
In a datawindow <LeftCTL + LeftSHIFT>can be used to switch to English and <RightCTL + RightShift> to swith betwen English and Arabic/hebrew. This switches the language and the cursor orientation.
It works fine when you are inside the column but the string is reversed when you leave it and the orientation in not kept when you come back to the column.
The same actions are handled differently in a single line edit.



CR:186977
CR Number:   186977
Product Name:   PB Enterprise
Product Component:   DB Informix
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 540 14 Jan 1999 Fixed
Description
PB6.5 Informix 7: UpdateBlob succeeds but SQLnRows returns 0
Workaround Description
 DisableBind=1



CR:187002
CR Number:   187002
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Dec 1998 Not a Bug
Description
Beta 7.0; File ->New -> xxx does not always enable Save



CR:187008
CR Number:   187008
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
19 Feb 1999 Fixed
Description
PB 6.5 and 7.0 Documentation and Help on AcceptText incorrect.



CR:187011
CR Number:   187011
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Jan 1999 Fixed
Description
PB 7.0 build 3259 DDDW's dddw.displaycolumn and dddw.datacolumn seemed to be stored internally reversed. This results in the data value displaying rather than the display value.



CR:187013
CR Number:   187013
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11 Jan 1999 Presently Not Targeted For Any Future Release Of This Product
Description
Beta 7.0; Library Painter, can't right mouse and Select All either in the treeview or listview.



CR:187039
CR Number:   187039
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   5.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Activate offsite a word ole application and clicked outside Powerbuilder and word applications. Powerbuilder doesn't get focus when closing word application.



CR:187048
CR Number:   187048
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC 4013 30 Dec 1998 Fixed
Description
Beta 7.0.00: Created a PFC-based application. ToDo list contains info about scripts to be pasted into objects. The script files (in the ToDo-list) have an extension of *.sru. But the files in the ...\pfc\wizsrce directory have an extension of *.scr



CR:187125
CR Number:   187125
Product Name:   PB Enterprise
Product Component:   DW DDDW
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 04 Mar 1999 Fixed
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
6.0 Regression: DW in querymode with dddw filtered to 0, causes an infinite retrieve of the dddw.
Workaround Description
 After filtering the dddw, check the dddw rowcount. If the rowcount is zero, then insert a blank row:
dwc.filter()
if dwc.rowcount() = 0 then
dwc.insertrow(0)
end if



CR:187129
CR Number:   187129
Product Name:   PB Enterprise
Product Component:   DB Sybase System
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
DECLARE of stored procedure with output parameter causes compile error "Can't use the OUTPUT option when passing a constant to a stored procedure"

It turns out the problem occurs when the stored procedure does not exist on the database. It is most frequently encountered when you have used the wrong database profile by mistake, or when you accidentally spell the stored procedure or argument name incorrectly in your script.

If possible, it would be nice to have an error message that is easier to interpret.



CR:187161
CR Number:   187161
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Closed
OS:   MS Windows 3.1
Original Version:   5.0.04
Fixed Version Build Resolution Date Closure Code (If Appropriate)
5.0.04 25 May 1999 Fixed
Description
Backspace does not behave consistently in an EDIT MASK
In certain configuration the cursor is stuck in the edit mask when using Backspace when it initially is in the decimal area.
Fixed in Powerbuilder 7.01



CR:187174
CR Number:   187174
Product Name:   PB Enterprise
Product Component:   DB DB2
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 ??? 30 Dec 1998 Fixed
Description
PBDIR60 native driver: A subsequent connection (following the disconnect from the first successful connection) made by the application then fails providing the error that MainframeConnect version must be greater than 11.06.00.0061. Their version is 11.06.00.0063 and it was obviously ok for the first connection.



CR:187178
CR Number:   187178
Product Name:   PB Enterprise
Product Component:   DW Synchronization
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Sep 1999 Fixed
Description
After sychronising a datastore using GetChanges() + SetChanges() a call to Update will not clear out the datastore delete buffer. Neither does ResetUpdate().

If Update() FAILS or if we do not call Update() after calling SetChanges and before ResetUpdate() the delete buffer is cleaned out by ResetUpdate().

A workaround exists and that is to use RowsDiscard() on the delete buffer if Update succeeds.
Workaround Description
 If Update() succeeds (returns 1) call RowsDiscard to clean out the delete buffer



CR:187181
CR Number:   187181
Product Name:   PB Enterprise
Product Component:   Windu/U
Status:   Closed
OS:   Solaris 2.5.1
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Multiple runs produce defuncted processes on UNIX



CR:187257
CR Number:   187257
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
12 Mar 1999 Not reproducible with latest version of the product available as of Resolution Date
Description
Selecting a printer via PrintSetup() does not reset default printer on app exit



CR:187273
CR Number:   187273
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
05 Jan 1999 Not a Bug
Description
PB 7.0 still using Win.ini to find Pb.ini



CR:187282
CR Number:   187282
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Open
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB 7.0 Enhancement Request: On Open wants object type view, not dropdownlistbox



CR:187286
CR Number:   187286
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 Oct 2007 Fixed
Description
PB 7.0 Enhancement Request: Object Wizards should open object as last step.



CR:187302
CR Number:   187302
Product Name:   PB Enterprise
Product Component:   Windu/U
Status:   Closed
OS:   Solaris 2.5.1
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
In a distributed application if an asynchrone call is made to a function which contains multiple calls to the PB Now() function, it hangs both the server and the clients.
Workaround Description
 Use Cpu() function instaed of Now()



CR:187313
CR Number:   187313
Product Name:   PB Enterprise
Product Component:   Library Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC0 4017 20 Jan 1999 Not reproducible with latest version of the product available as of Resolution Date
Description
EAStudio 3.0 Beta 4 build 4007
Attempt to edit an overloaded userobject function from the search results dialog of the library painter causes a gpf.



CR:187323
CR Number:   187323
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11 Jan 1999 Not reproducible with latest version of the product available as of Resolution Date
Description
Beta 3 PB 7.0: Changes to x position in window painter are not saved.



CR:187324
CR Number:   187324
Product Name:   PB Enterprise
Product Component:   DB Sybase System
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
In PBSYC, Stored procedures invoked through RPCs (sp update feature in 7.0 or local external function in transaction UO) cannot contain arguments defined as money or smallmoney.
Workaround Description
 The arguments have to be defined as decimal(20,4) or decimal(10,4) in the stored procedure.



CR:187331
CR Number:   187331
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Jul 1999 Not a Bug
Description
Enhancement. Datawindow should interpret tab characters correctly. They should not paint as boxes.

Development: We do not expand tabs because we do not support the setting of tab-widths in the DW (an enhancement is required to handle tabs fully).



CR:187336
CR Number:   187336
Product Name:   PB Enterprise
Product Component:   Installation
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Mar 1999 Presently Not Targeted For Any Future Release Of This Product
Description
EAStudio 3.0 Beta 3
install screen word wrap problem for screen on ODBC 3.5 - cosmetic



CR:187342
CR Number:   187342
Product Name:   PB Enterprise
Product Component:   DB Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
08 Jan 1999 Fixed
Description
EA Studio Beta 3: Enhancement Request:
In the database painter, when a SQL statement is
executed, it would be nice if the results tab was automatically selected
when the statement was complete. Currently, you hear the 'beep' and then
have to click on the tab.



CR:187362
CR Number:   187362
Product Name:   PB Enterprise
Product Component:   Script Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Jan 1999 Duplicate
Description
EA Studio Beta 3:

In script, use the Find menu. It only reports matches the first time through. Even if you scroll back up to the top of the script, click in the upper left corner to position the cursor at the beginning of the script. Then use the Edit...Find function again on the exact same string you already searched for and found several times, the microhelp reports the string not found, and the string is not highlighted, although it was the first time for using the Find option.



CR:187367
CR Number:   187367
Product Name:   PB Enterprise
Product Component:   Windu/U
Status:   Closed
OS:   Solaris 2.5
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
RUN fails when executable name contains a dot in its name



CR:187396
CR Number:   187396
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.0.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 549 27 Jan 1999 Fixed
Description
6.0.0 Regression: dw.create fails when syntax includes Icelandic extended ascii



CR:187449
CR Number:   187449
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Open
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
7.0 beta enhancement request: Better, more robust error messages from Jaguar



CR:187452
CR Number:   187452
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
6.5.00 08 Jan 1999 Fixed
Description
A DDDW defaults to a '0' value when a new row is inserted starting in build 502 and still occuring through build 530. Same problem occurs in PB 7.0 build 4015.
In the sample provided '0' is a legitamate value and when a new row is inserted which is blank at this point the empty field is being interpreted as a '0' and the display value for the '0' is displaying. Prior to build 502 the field would be left blank.



CR:187468
CR Number:   187468
Product Name:   PB Enterprise
Product Component:   DPB
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Feb 2004 EOL'd version. Not to be Fixed.
Description
EA Studio 3.0 BETA:
Problems with Distributed PB in a mixed NT/Novell environment. SetLibraryList does not work for client application.



CR:187485
CR Number:   187485
Product Name:   PB Enterprise
Product Component:   Window Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 5004 25 Jan 1999 Not reproducible with latest version of the product available as of Resolution Date
Description
PB 7.0 Beta 3 tested with build 4015.

Changing menu assignment causes invalid page fault in PBVM70.dll and occasionally in PBDEV70.dll. Sample exhibits behavior when used with Tutorial but can also be demonstrated when simply trying to change assigned menus in PB examples.



CR:187562
CR Number:   187562
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   5.0.04
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 Sep 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Cannot create a dw sp if sp contains convert function on datetime datatypes
Workaround Description
 1. Do conversion in pb and pass the format you want
2. Use convert function on any datatypes (char in this case) but datetime (Ms sql server online help tells in this case conversion is implicit)



CR:187570
CR Number:   187570
Product Name:   PB Enterprise
Product Component:   DB SQLAnywhere
Status:   Open
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 5007
Description
Ability to connect to sql anywhere 6 (ASA6) via TDS (open client)



CR:187587
CR Number:   187587
Product Name:   PB Enterprise
Product Component:   Machine Code Exe Creation
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
01 Feb 1999 Fixed
Description
EA Studio Beta:
Distributed Powerbuilder machine code executable causes a GPF at runtime. The same application runs okay with Pcode.



CR:187620
CR Number:   187620
Product Name:   PB Enterprise
Product Component:   Help
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
08 Jan 1999 Fixed
Description
EA Studio 3.0 Beta
The documentation (online help) for SaveAs states that the third argument is optional, but the script will not compile if it is missing. Either this is a bug or the documentation is incorrect.



CR:187646
CR Number:   187646
Product Name:   PB Enterprise
Product Component:   UO Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Jan 1999 Fixed
Description
EA Studio 3.0 BETA
GPF switching between user object functions in user object painter.



CR:187648
CR Number:   187648
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
20 Jan 1999 Not a Bug
Description
EA Studio 3.0 BETA
In the Keyboard Shortcuts you can assign the same key combination to multiple things.



CR:187649
CR Number:   187649
Product Name:   PB Enterprise
Product Component:   Help
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC1 02 Feb 1999 Fixed
Description
EA Studio 3.0 BETA:
Online Help error: System Options Dialog Box: General Tab: references "pb60.dbg" which should be "pb70.dbg".



CR:187666
CR Number:   187666
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
18 May 1999 Fixed
Description
EA Studio 3.0 BETA:
HTML Datawindow Preview does not show all options, eg. border



CR:187691
CR Number:   187691
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Aug 2000 Fixed
Description
The sample is a tabular report with a nested report in the summary band. There are also a fairly large text object in the summary band which makes the band fairly large. When the number of records in the base report, plus the text object, plus the nested report all fit on one page it prints as one would expect. If however the remaining records from the base report, plus the text object, plus the nested report do not fit on the remainder of the page, the last record of the base report is placed at the top of the following page along with the text object and the nested report. Thi shappens even though there is plenty of space on the preceeding page for this last record to fit. Regardless of space remaining it is always only one record that is printed at the top of the page with the summary band.

If you remove the nested report or the text objects it still will not print correctly unless the actual space inthe summary band is shrunk small enough to fit on the page. Expected behavior is that this last record would print in the available space and then the break would be made to the next page where the entire content of the summary band would print.



CR:187726
CR Number:   187726
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 8006 04 Jan 2000 Fixed
Description
If you are doing asynchronous datawindow retrievals with Oracle native drivers, the retrieves will not be asynchronous if the datawindow has retrieval arguments.



CR:187750
CR Number:   187750
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Oct 2002 Presently Not Targeted For Any Future Release Of This Product
Description
Wrong structure reference passsed to an external C dll
Workaround Description
 Write a dummy DLL function that just returns 0 but that takes as parameter the global variable structure.
Calling this DLL function in the script and all works fine.



CR:187751
CR Number:   187751
Product Name:   PB Enterprise
Product Component:   OLE - Active X - OCX
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 RC0 4024 13 Jan 1999 Fixed
Description
OCX (MAPINFO MapXV3 ) from MapInfo gives PB GPF at "0x03273ab2" when trying to insert it on a window.



CR:187779
CR Number:   187779
Product Name:   PB Enterprise
Product Component:   PB GUI
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   7.0.00 Beta 3
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Jan 1999 Not reproducible with latest version of the product available as of Resolution Date
Description
EA Studio 3.0 beta:
Frequent GPFs closing painters. No code lost, but OS must be restarted.



CR:187818
CR Number:   187818
Product Name:   PB Enterprise
Product Component:   DW Expression
Status:   Closed
OS:   MS Windows NT 4.0
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
7.0.00 Beta 2 2226 18 Jan 1999 Fixed
Description
Set a Filter on a datawindow with the expression :'column LIKE '%test%%'
Powerbuilder crashes with Dr Watson error.
A datawindow filter ending IN '%%' will CAUSE an access violation.

Occurred in PB 6.5 (non-pfc and pfc applications both get system crashes).
PB software has a gpf because %% is not understood.
Workaround Description
 Create a function that replaces all %% by % in filter.



CR:187833
CR Number:   187833
Product Name:   PB Enterprise
Product Component:   Generators
Status:   Closed
OS:   Microsoft Windows 95
Original Version:   6.5.00
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11 Feb 1999 Fixed
Description
Passing arguments by reference from ASP calling a PB generated COM object fails





--------------------------------------华丽的分割线-------------------------------------------------------------------------

Sybase SQL Anywhere数据库恢复工具ReadASADB:

之前就已经研发成功了能够从Sybase SQL Anywhere的DB文件中恢复数据的工具: ReadASADB。
此工具支持ASA v5.0, v6.0, v7.0, v8.0, v9.0, v10.0, v11.0, v12.0, v16.0, v17.0等版本。
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具。
恢复Sybase SQL Anywhere的工具在国内处于领先水平。

Sybase SQL Anywhere数据库恢复工具ReadASADB功能
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具
  1. 适用于所有的SQL Anywhere版本    包括:5.x,6.x,7.x,8.x,9.x,10.x,11.x,12.x,16.x,17.x
  2. 适用于所有的UltraLite版本
  3. 能够恢复出来表结构和数据
  4. 能够恢复自定义数据类型
  5. 能够恢复存储过程等对象的语法
  6. 能够导出到目标数据库
  7. 能够导出到SQL文件并生成导入脚本
  8. 支持多种字符集,包括:cp850、cp936、gb18030、utf8等
  9. 能够恢复未加密或者简单加密类型的数据
  10. 简单易用
  11. 限制:不支持AES加密的数据文件
请参考:研发成功了从Sybase SQL Anywhere的DB文件上恢复数据的工具
            SQL Anywhere数据库非常规恢复工具ReadASADB使用介绍

Sybase SQL Anywhere数据库恢复工具ReadASADB适用场景

各种误操作:

  1. 误截断表(truncate table)
  2. 误删除表(drop table)
  3. 错误的where条件误删数据
  4. 误删除db或log文件
  5. 误删除表中的字段

Sybase SQL Anywhere数据库恢复工具ReadASADB的应用场景:

1.因为物理磁盘故障、操作系统、系统软件方面或者掉电等等原因导致的Sybase SQL Anywhere数据库无法打开的情况;
2.误操作,包括truncate table,drop table,不正确的where条件导致的误删除等;
Sybase SQL Anywhere无法打开时,比较常见的错误是:Assertion failed。
如:
1、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Checkpoint log: invalid bitmap page -- transaction rolled back
2、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Page number on page does not match page requested -- transaction rolled back
3、Internal database error *** ERROR *** Assertion failed:200502 (9.0.2.2451) Checksum failure on page 23 -- transaction rolled back
4、File is shorter than expected
5、Internal database error *** ERROR *** Assertion failed: 201116 Invalid free list index page found while processing checkpoint log -- transaction rolled back
6、*** ERROR *** Assertion failed: 51901 Page for requested record not a table page or record not present on page
7、*** ERROR *** Assertion failed: 201417 (7.0.4.3541) Invalid count or free space offset detected on a table page
8、Internal database error *** ERROR *** Assertion failed: 201425 (8.0.3.5594) Invalid count or free space offset detected on a free list page -- transaction rolled back.
9、Internal database error *** ERROR *** Assertion failed: 100702 (8.0.1.2600) Unable to modify indexes for a row referenced in rollback log -- transaction rolled back


-------------------------------------------------------------------------------------------

Sybase ASE数据库恢复工具READSYBDEVICE:

一个不依赖数据库管理系统、直接从Sybase数据库设备文件上提取数据的业内领先的恢复工具!
能够从损坏的Sybase ASE设备文件(.dat)上提取数据的非常规恢复工具。

Sybase ASE数据库恢复工具READSYBDEVICE的主要功能:

  1. 被勒索病毒加密数据文件及备份文件情况下的恢复;
  2. 系统崩溃只剩下数据文件的情况下的恢复,甚至数据库文件不存在而只有损坏的备份文件情况下的恢复;
  3. 因断电、硬盘坏道等造成数据库文件损坏情况下的恢复;
  4. delete数据恢复、误update数据恢复、误删除表(drop)恢复、误truncate表恢复 等;
  5. 各种Sybase内部系统表损坏、索引错误的修复;
  6. master数据库损坏而无法正常运行情况下的恢复;
  7. Sybase数据库被标记为可疑,不可用等情况的恢复;
  8. Sybase数据库中数据文件内部出现坏块情况下的恢复;
  9. Sybase数据库无数据文件但有日志文件的情况下的恢复;
  10. Sybase数据库只有数据文件无任何日志文件的情况下的恢复;
  11. Sybase数据文件被误删除情况下的碎片提取恢复;
  12. 磁盘阵列上的Sybase数据库被误格式化情况下的数据库恢复;
  13. 数据库sysobjects等系统表损坏无法正常应用情况下的恢复;
  14. Sybase数据库还原数据库出现失败情况下的恢复;
  15. Sybase数据库只剩下损坏的备份文件情况下的恢复。

Sybase ASE数据库恢复工具READSYBDEVICE支持的版本:

Sybase ASE 11.0.x,11.5.x,11.9.x,12.0.x,12.5.x,15.0.x,15.5.x,15.7.x,16.0.x


-------------------------------------------------------------------------------------------

SQL Server数据库恢复工具SQLRescue:

一个不依赖数据库管理系统、直接从SQL Server数据库文件上提取数据的业内领先的恢复工具!
能够从损坏的SQL Server数据库文件(.mdf)上提取数据的非常规恢复工具。

SQL Server数据库恢复工具SQLRescue的主要功能:

  1. 系统崩溃只剩下数据文件的情况下的恢复,即无日志文件或者日志文件损坏情况下的恢复;
  2. 断电导致数据库文件损坏情况下的恢复;
  3. 硬盘坏道造成数据库损坏情况下的恢复;
  4. 数据文件内部存在坏页情况下的恢复;
  5. 企业管理器误删除数据表记录,管理软件误删除数据表记录的恢复;
  6. 并闩锁错误、格式化、误删除后导致软件不能使用的情况;
  7. 无法读取并闩锁页sysindexes失败情况下的修复;
  8. 数据文件被误删除情况下的碎片提取恢复;
  9. 系统表损坏、索引错误、误删除数据库表、删除记录的数据找回;
  10. master数据库损坏而无法正常运行情况下的恢复;
  11. 数据文件无法附加情况下的数据恢复;
  12. 数据库被标记为可疑,质疑,不可用等情况的恢复;
  13. 数据库sysobjects等系统表损坏情况下的恢复;
  14. 数据被误(drop、delete、truncate)删除表数据的恢复,误update后的数据恢复等;
  15. 还原时报一致性错误,错误823等情况下的数据恢复,各种错误提示的数据库文件修复;
  16. 数据库被误格式化等情况下的数据库恢复;
  17. 日志收缩造成数据库损坏情况下的恢复;
  18. 仅剩损坏的备份文件情况下的恢复。

SQL Server数据库恢复工具SQLRescue技术特点:

只要SQL Server数据库的数据文件存在,我们就有办法帮您从数据文件中找回重要数据。
  1. 从数据文件中直接恢复数据
  2. 不能附加时直接恢复数据并生成新的数据库
  3. 系统表损坏的数据库修复
  4. 快速修复SQL 823错误、连接中断错误

SQL Server数据库恢复工具SQLRescue支持的版本:

Microsoft SQL Server 7.0, 2000, 2005, 2008, 2008R2, 2012, 2014, 2016, 2017,2019。
+-------------------------------------华丽的分割线-------------------------------------------------------------------------