提供7*24专业Sybase数据库远程及现场技术支持,Sybase ASE及Sybase SQL Anywhere数据库修复服务,
请联系电话: (微信),QQ: 289965371!
We supply technical support for Sybase ASE and Sybase SQL Anywhere, also have many years of experience in recovering data from damanged Sybase devices.
Please contact us:
Phone:
Wechat: 13811580958
QQ: 289965371 联系我们获取数据库技术支持!
Email: 289965371@qq.com
扫描下方微信,联系我们:
扫描雨翰数据恢复官方微信获取专业数据库恢复服务

 

随着Sybase被完全整合到SAP下,Sybase原来的支持网站被SAP Support Portal取代。
只有购买了SAP服务的用户才能使用账号登录SAP Support Portal进行介质下载、补丁升级、报Incident等。
考虑到Sybase数据库的初学者或者没有购买原厂服务的Sybase客户情况,现提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息。
在SAP Support Portal网站或者google上搜索Targeted CR List for ASE,可以看到针对不同版本的CR(CR表示Change Request)简单描述信息列表。
需要注意的是:Targeted CR List for ASE列出的CR虽然绝大多数是BUG,但有一些是更改需求。
以下提供SAP ASE/IQ/RS/SDK/SQL Anywhere/PB等产品的BUG信息!

如有问题,请联系我!

QQ :289965371 联系我们获取数据库技术支持!
Email:
不仅仅包括BUG的详细描述信息,还包括首次报告BUG的平台、数据库版本以及BUG修复历史过程;有些BUG还提供了Workaround来临时解决该BUG带来问题。

 

CR:570340
CR Number:   570340
Product Name:   PB Enterprise
Product Component:   Menus - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Jul 2009 Workaround
Description
Toolbar images for a contemporary menu have a gray background when images are in the same directory as application.



When the images (first.bmp,next.bmp,prior.bmp and last.bmp) are moved to another

directory that is in the system path, then the gray background is not there.



Resolution: Not to be fixed. Too risky and may cause a regression. Pathing issue

does not occur in pb12 (build 2063).



CR:570479
CR Number:   570479
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
text color in a DDLB column not rendered as for Windows DDLB control.



CR:570693
CR Number:   570693
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Jul 2009 Fixed
Description
PB client calling a webservice running on websphere

results in a memory leak.



The application eventually produces the following error and then crashes pb:

There is a runtime error when invoking the Web Service APPLICATION. The

definition of the method signature in the Web Service is wrong--the data doesn't

match the parameter definition.



Using websphere 6.1. The web service generates pdf documents uses up memory each successive time the web service is invoked until Powerbuilder crashes.



CR:570817
CR Number:   570817
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
12 May 2009 Fixed
05 Jun 2009 Fixed
Description
Memory leak from retrieving file from WebService



CR:571043
CR Number:   571043
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
07 May 2009 Presently Not Targeted For Any Future Release Of This Product
Description
A customer has an elaborate datawindow using nested reports built in Powerbuilder 8. Within Powerbuilder 8 he uses the getfullstate powerscript function to convert this datawindow into a blob and store it in his Oracle database.



Should he be able to use this blob created in Powerbuilder 8 and be able to do a selectblob of the powerbuilder 8 datawindow and then do a setfullstate in a Powerbuilder 11 application?



Would this be considered supported?



Parts of the report display fine but pages are missing.



CR:571162
CR Number:   571162
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Attributes in an export template are not stored in the order they were entered



CR 309840 seem to occur again.



CR:571184
CR Number:   571184
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Feb 2010 Fixed
Description
SCC source integration P4SCC 2007.3 or 2008.2



When refreshing source control status, the SccQueryInfo

call gets into an infinite loop within the Perforce dll's



CR:571249
CR Number:   571249
Product Name:   PB Enterprise
Product Component:   EJB Client
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
10 Jul 2009 Fixed
Description
EJB client to Weblogic



Some properties of type any of java classes can not be expanded within the debugger



CR:571280
CR Number:   571280
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Jun 2009 Not a Bug
Description
A Barcode font is not displaying or printing properly after upgrade from PB 11.0 to 11.5.

This does appear to be a regression. It works OK in build 7518 and earlier of PB 11.x. Later versions of 11.2 display the barcode incompletely as does the latest version of 11.5, build 3143.



CR:571286
CR Number:   571286
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
The RightToLeft Property currently applies to:



Application and Window objects, and CheckBox, DataWindow, DatePicker, DropDownListBox, DropDownPictureListBox, EditMask, GroupBox, InkEdit, ListBox, ListView, MonthCalendar, MultiLineEdit, PictureListBox, RadioButton, SingleLineEdit, StaticHyperLink, StaticText, and TreeView controls



Customer would like the RightToLeft property to apply to Computed Fields in the datawindow control



CR:571418
CR Number:   571418
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
17 May 2009 Not a Bug
Description
SAP 16 Webservices



EasySoap client gave error "Cannot parse wsdl file" when generating proxies.



CR:571626
CR Number:   571626
Product Name:   PB Enterprise
Product Component:   EJB Client
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 May 2009 Not a Bug
26 May 2009 Presently Not Targeted For Any Future Release Of This Product
Description
Getting an error calling method of a pbni object when doing a CreateJavaInstance.



CR:571814
CR Number:   571814
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Jul 2009 Fixed
Description
When connected to MSSQL using the SNC driver, pb

is crashing on rollback using <transaction>;



A crash is happening in the u_mgr_data/xfi_rollback. In the debugger, autocommit

is set to false and the transaction object is valid.





A dump file shows the app is crashing in the:

PBSNC115!PBOLEDB_COMMAND_BLK::RollBack+1

14f025a1 8b4908 mov ecx,dword ptr [ecx+8]



DEFAULT_BUCKET_ID: NULL_POINTER_READ



CR:571906
CR Number:   571906
Product Name:   PB Enterprise
Product Component:   DW Printing
Status:   Open
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Jul 2009 Fixed
Description
The customer needs to load various text files (generated by Pro*C or Oracle package on

UNIX)into a RichText DataWindow in their PowerBuilder application and then print out the

text files with Landscape Orientation (most of the time) from there. The main issue

encountered is that the Richtext DW fail to use Page Orientation specified by PrintSetup()

at runtime.
Workaround Description
 Use datawindow object property instead "DataWindow.Print.Orientation=0,1,2"

However, customer does not consider as workaround.



CR:571920
CR Number:   571920
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Open
OS:   Windows XP
Original Version:   11.0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
When opening a workspace that is under source control with P4 sometimes a crash can occur when connecting to P4 by a user having a P4 password or when the password has expired. Enabling logging in the pb.ini might prevent the crash.



CR:571930
CR Number:   571930
Product Name:   PB Enterprise
Product Component:   PB.NET WebForm
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Jul 2009 Fixed
Description
Problem with the tab order on webform when PBDataWindowEnableDDDW=true. Tab order on webform is not the same as using pb native.



After a dddw is expanded, the tab order appears to be lost.



Using IE 6 and 7 for testing.



CR:571956
CR Number:   571956
Product Name:   PB Enterprise
Product Component:   BAM Deployment
Status:   Closed
OS:   Windows XP
Original Version:   6.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Aug 2009 Fixed
22 Jul 2009 Fixed
Description
The deployment of a large PB workspace causes an java.lang.OutOfMemoryError in easerver.

When they are all deployed at once (RMB on Workspace in PB system tree -> Deploy) the server will get java.lang.OutOfMemoryError: PermGen space. After this the server has to be restarted.
Workaround Description
 Deploy each project step by step, not in one single complete action.



CR:571977
CR Number:   571977
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Feb 2010 Fixed
Description
The customer has a datawindow with a stored procedure update. There are many arguments in the stored procedure that are marked as not used in the sp update properties. Only 9 arguments are passed. The datatypes of those 9 match but the error "Implicit conversion from datatype 'INT' to 'VARCHAR' is not allowed. Use the CONVERT function to run this query." happens on an update. A database trace doesn't really show anything helpful.



CR:572081
CR Number:   572081
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Jun 2009 Fixed
05 Aug 2009 Fixed
Description
Transparent background of png pictures are drawn incorrectly

when a rectangle is put behind it or when the picture is dynamically set.



CR:572336
CR Number:   572336
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Nov 2009 Not reproducible with latest version of the product available as of Resolution Date
Description
When pb client calls the pb web service running on

IIS, windows event view may report the following error:



Event Type: Error

Event Source: ASP.NET 2.0.50727.0

Event: EventType clr20r3,P1 w3wp.exe, P2 6.0.3790.3959, P3 45d6968e, P4 sybase.powerbuilder.interop, P5 11.0.0.0, P6 471eaa9a, P7 4e9, P8 1f, P9 system.accessviolation, P10 NIL

Event ID: 1334

Description:

An unhandled exception occurred and the process was terminated.

Application ID: /LM/W3svc/1/Root/eonwebservice

Exception: System.AccessViolationException

Message: Attempted to read or write protected memory. This is often an

indication that other memory is corrupt.

Stack Trace: at b(oa*, PBTransaction, Boolean)

at c(oa*, PBTransaction)

at Sybase.PowerBuilder.DB.PBSQL.Stop(IntPtr dbthis, PBTransaction transaction)

at Sybase.PowerBuilder.PBSessionBase.Stop.Transaction(PBTransaction trans)

at Sybase.PowerBuilder.PBTransaction.Dispose(Boolean disposing)

at Sybase.PowerBuilder.PBPowerObject.Finalize()



Test shows that the exception won't affect PB Webservice in the opera application

since the iis can automatically restart the process w3wp.exe immediately after its stopped.



CR:572499
CR Number:   572499
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
The issue is, that it seems that when targetting a O9 database the string that can be passed is twice as big as the one against an o10 db server.



CR:572911
CR Number:   572911
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11 Jun 2009 Presently Not Targeted For Any Future Release Of This Product
Description
Date() function returns value from invalid date on some windows installations.



It seems that on these systems PB does not use the set regional settings (english uk), it uses some sort of US date settings instead (yy/mm/dd or yyyy/mm/dd), hence the wrong output.



CR:573079
CR Number:   573079
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
BindSPInput=1 makes db oracle to bind proc input parameters. However Oracle XML type can't be bound as either String or Clob/Nclob, and XML type in OCI is not a simple data type and can't be used directly like other data types. So Function spec of Oracle11g explicitly pointed out that xml procedure parameters type is not currently supported.



CR:573081
CR Number:   573081
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
15 Jun 2009 Fixed
Description
Memory leak from retrieving PSR file from WebService. After 7 iterations can't get the file anymore.



CR:573229
CR Number:   573229
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
21 Feb 2010 Fixed
Description
Customer has PB 6.5 psr files and has migrated to PB 11.5. When they initially set the dataobject to the psr file it seems to load and display properly. But then if they do a SaveAs PSReport! that returns success, but the resulting psr is empty - no data. If you load that new PSR, it is empty.



Using an 11.5 psr there is no problem loading it, making changes, save it again as a psr, the new psr loads and displays properly. The customer needs to be able to do the same to these older psrs.



CR:573409
CR Number:   573409
Product Name:   PB Enterprise
Product Component:   DB Painter
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11.5 09 Jun 2009 Fixed
Description
OS: Windows XP SP2

Versions and Build #s Tested: PB 11.5_2506

Database/Driver File/Version: SYC connecting to ASE 12.5.4



Comments: Customer has above 1000 stored procedures created with "sp_" prefix. But Pb, by default, considers these stored procedures as System Procedures.

As a consequence, customer needs to right-click and enable "Show System Procedures" to make them visible. This was reproduced here.



CR:573434
CR Number:   573434
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
09 Oct 2009 Fixed
Description
The customer has a large text column with autosize height in the detail band. When displaying in print preview, sometimes this column is clipped on the bottom with only the top half of the last line showing. PSE could only see the clipping with my DPI set to normal (96 DPI).



CR:573443
CR Number:   573443
Product Name:   PB Enterprise
Product Component:   Documentation
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
08 Jan 2010 Fixed
Description
Certain toolbar menu icons are not clearly recognizable

between enable and disable state.



CR463051 addressed the problem and created a new property (PBTOOLBARDISABLEMODE=1 ) to add as a system environmental variable.



Please document this property-- PBTOOLBARDISABLEMODE=1



CR:573610
CR Number:   573610
Product Name:   PB Enterprise
Product Component:   Rich Text
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
02 Sep 2009 Fixed
Description
When a rtf doc contains INCLUDEPICTURE and references

a .bmp for .gif, the picture does not show in in a rte control or richtext dw.



The rtf doc contains:

{INCLUDEPICTURE "C:/DevSample/ESSIG1.GIF" \* MERGEFORMAT \d }

{INCLUDEPICTURE "C:/DevSample/ESSIG1.BMP" \* MERGEFORMAT \d }



It works ok in PB 10.5.2



CR:573630
CR Number:   573630
Product Name:   PB Enterprise
Product Component:   PB.NET WebForm
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Jul 2009 Fixed
Description
When inserting data into a new row and tabbing to

the dddw where the 'empty string is null' is checked, causes the previous column's data to disappear.





Webform is doing a postback. Only happens when empty string is null is checked.



CR:573774
CR Number:   573774
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11.5 09 Jun 2009 Fixed
Description
When calling Functions with similar names after a certain length of the identifier in oracle packages it seems we try to call the wrong function.
Workaround Description
 name the functions different at least after the 9th character.



CR:573813
CR Number:   573813
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Microsoft Windows 2003
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
09 Jun 2009 Fixed
16 Jul 2009 Fixed
Description
A PowerBuilder EAServer application is upgraded in which some method calls are changed.



if a client application uses a bad or old proxy object then PowerBuilder

within EAServer gets a fatal error on the server side and EAServer can go down.



CR:573822
CR Number:   573822
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
20 Aug 2009 Not a Bug
Description
Opening the responds window with an RTE control on it cause a

Powerbuilder Application Execution Error
Workaround Description
 Workaround: moving statement into the open event of the w_ancastor window.



CR:573964
CR Number:   573964
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
09 Jun 2009 Fixed
16 Jul 2009 Fixed
Description
When a PowerBuilder client application is using a bad proxy object then PowerBuilder

within EAServer gets a PB INTERNAL EXCEPTION.



CR:574017
CR Number:   574017
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 Jun 2009 Fixed
16 Jul 2009 Not a Bug
Description
Using FileReadEx on some machines crashes when reading a large file (380069 KB).



1 - Tested on Vista machine, PB 11.5.1 build 4011, 4 GB memory. Ran fine, returned correct bytes in less than a minute.

2 - Tested on XP machine, PB 11.5.1 build 4011, 1 GB memory. Crashed in pbvm115.dll after running for a few minutes.



Customer has an XP machine with 3 GB memory and says he is crashing.



CR:574021
CR Number:   574021
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Oct 2009 Fixed
02 Dec 2009 Fixed
Description
The customer has several button display issues using both Window Classic, Windows Vista, and Windows XP themes. The look of the pictures inside the buttons and the size of the buttons themselves using each theme are inconsistent. The goal of this CR is to get button sizes to be consistent across all button types and graphics to look correct on all styles of buttons using all Windows themes in any Windows operating system version.



1) Datawindow buttons can be given a picture but have no originalsize property. The picture scales instead of the button resizing around the picture causing graphics to look unprofessional using modern or classic themes. The button should have an originalsize property that behaves as it does for window picture buttons.



2) In PowerBuilder the datawindow picture buttons always display using the classic style when viewed on the datawindow regardless of the display theme in use. For example, if using the standard Windows Vista or Windows XP themes the buttons appear square on the datawindows, but when window buttons are viewed on a window object the buttons appear with rounded edges. DW buttons should behave the same.



3) In modern display themes Window commandbuttons have multitone gradient backgrounds while picturebuttons do not. This gives an inconsistent look. Picturebuttons should have similar capability.



CR:574126
CR Number:   574126
Product Name:   PB Enterprise
Product Component:   Rich Text
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Jun 2009 Fixed
Description
Setting PaperOrientation property for RichTextEdit control to Landscape! is not respected during printing, unless to change the Orientation manually in the Printing Preferences.
Workaround Description
 set printer properties in printsertup dialog before printing.



CR:574186
CR Number:   574186
Product Name:   PB Enterprise
Product Component:   DW Rich Text
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Jul 2009 Fixed
Description
When having a richtext edit stlye column that covers more than a page in printpreview then there is some part of the column cut off and another empty page gets displayed.

Normal column edit style works ok.



CR:574194
CR Number:   574194
Product Name:   PB Enterprise
Product Component:   P-Code Exe Creation
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Sep 2009 Fixed
10 Oct 2009 Fixed
Description
The problem is that background pictures are not displayed at runtime when the images are placed in a PowerBuilder resource file and linked into the exe.
Workaround Description
 deploy the images directly



CR:574329
CR Number:   574329
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
24 Aug 2009 Fixed
06 Aug 2009 Failed
Description
EAServer 5.5 PowerBuilder 11.2 Build 8616



PowerBuilder Internal Exception



A crash occured in the activate event of a component



CR:574466
CR Number:   574466
Product Name:   PB Enterprise
Product Component:   Menus - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
14 Oct 2009 Fixed
Description
pbr graphics are not appearing on menu at runtime.

In pb 11.5, bmp,png and jpg are not appearing on menu.



In pb 11.2, jpg are not appearing (png is not supported until 11.5)



Problem happens for both pcode and machine code. It does not appear that

the graphics are set in the executable.



CR:574857
CR Number:   574857
Product Name:   PB Enterprise
Product Component:   Rich Text
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Jul 2009 Fixed
Description
CopyRTF function on RichTextEdit Control is not working and does not return the rte string.

Worked fine in PB 9 and 10.5.



CR:574894
CR Number:   574894
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Jul 2009 Fixed
Description
Customer has his own JSP pages with DDDWs on them and when he migrated from PB 10.5/EAS 5.1 to PB 11.2/EAS 5.5 the dropdowns are not working as expected. They seem to need to be clicked several times and still then the selected state is not selected.



CR:574909
CR Number:   574909
Product Name:   PB Enterprise
Product Component:   PB.NET WebForm
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Jun 2009 Third Party Problem
Description
Customer has used a third party command button in their win32 application and now when deploying to a webform it is not showing when run. There are unsupported features reported for one event and some properties but not sure why it is not displaying.



CR:575262
CR Number:   575262
Product Name:   PB Enterprise
Product Component:   Language - Runtime
Status:   Open
OS:   Vista
Original Version:   12.0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request:

Make it possible to create 64-bit applications to be able to use more than 2GB virtual memory.



CR:575287
CR Number:   575287
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Aug 2009 Fixed
14 Oct 2009 Fixed
Description
[Currency] display format replaces a dot with a comma

In the Regional Options, if the Currency Symbol contains a dot (for example kr.), the dot is replaced by a comma when using the [Currency] display format.



CR:575415
CR Number:   575415
Product Name:   PB Enterprise
Product Component:   PB.NET WebForm
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11.2 29 Jul 2009 Fixed
Description
The indicator of DW does not work correctly in the window opened by another instance.



CR:575536
CR Number:   575536
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Jul 2009 Fixed
Description
When usehwnd=no is set, the wrong object's events in a sharedata are getting fired.



The SQLPreview, RetrieveEnd,UpdateEnd do not have any/correct arguments.



The n_cst_global/of_test has the sharedata().

IF ids_Test.ShareData(au_DW) = 1 THEN

IF THIS.of_CreateTempTable(TRUE) = 1 THEN

ll_RowCount = ids_Test.Retrieve()



I believe where the problem is in the second retrieve:

IF li_rc = 1 THEN

ll_RowCount = au_DW.Retrieve()



CR:575545
CR Number:   575545
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 Nov 2009 Not reproducible with latest version of the product available as of Resolution Date
Description
PB is crashing when using ALT-S for a shortcut with a button.



The dump file shows the crash is happening in:

msvcr71!wcsstr+13

Default_Bucket_ID: Invalid Pointer Read

BUGCHECK_STR: APPLICATION_FAULT_INVALID_POINTER_READ_STRING_DEREFERENCE



CR:575975
CR Number:   575975
Product Name:   PB Enterprise
Product Component:   MAPI
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 Jul 2009 Not a Bug
Description
mailSaveMessage function fails.



CR:576153
CR Number:   576153
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
The Date() function should have a second parameter for format argument.



CR:576157
CR Number:   576157
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
07 Sep 2009 Fixed
Fixed
Description
Which wsdl syntax does PB adhere to and are there any recommendations that can be given to customers who have the need to access certain web services. How to find out what is supported or not.



CR:576183
CR Number:   576183
Product Name:   PB Enterprise
Product Component:   DW Painter
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
03 Sep 2009 Consult Complete
Description
After adding a column to DW select statement with view the columns get renamed, the datatypes are being changed, the update properties are lost and the sort order is lost as well.



CR:576207
CR Number:   576207
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11.5 10 Jul 2009 Fixed
Description
OS: Windows XP SP3

Versions and Build #s Tested: PB 11.5_3127

Database/Driver File/Version: SNC connecting to SQL Server 2005 database



Comments: Enable SNC to allow multiple table selection in Paste Special/SQL/Update or Delete. Currently, only one table can be selected when using SNC.



The feature already exists for ASE, SYC and ODBC/JDBC (ase/asa/ms sql server) interfaces.
Workaround Description
 Write the UPDATE/DELETE query manually instead of using Paste Special feature for SNC.



CR:576446
CR Number:   576446
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Open
OS:   Linux
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Display as Picture property not working in xHTML on Linux.



CR:576452
CR Number:   576452
Product Name:   PB Enterprise
Product Component:   DW Graph
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Jul 2009 Fixed
Description
A datawindow Bar3D graph does not display unless

the type is changed to a different type and then changed back to Bar3D.



CR:576465
CR Number:   576465
Product Name:   PB Enterprise
Product Component:   Rich Text
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
When editing in a richtextedit control typing Ctrl-z will undo the last item typed and typing Ctrl-y right after that will put back what was removed by Ctrl-z. There is an

Undo() rte function that will do the same thing as Ctrl-z. However, there isn't a corresponding Redo() function. The customer would like to see a Redo() rte function.



CR:576659
CR Number:   576659
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Open
OS:   Windows XP
Original Version:   11.1
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Consult request. The Team Sybase customer is getting the following error in the EAServer log file:



2009-06-09 10:52:42.715 WARN Thread-414 Probable cause: unexpected failure or abnormal shutdown of client application or client host.



They are looking for any ideas. What does this error mean? What could be causing it?



CR:576662
CR Number:   576662
Product Name:   PB Enterprise
Product Component:   Rich Text
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Jul 2009 Fixed
Description
The issue is if you first insertdocumentinto an rte, an rtf document that has some kind of table, and then do a selecttextall() and a clear(), the table outline is left behind. This accumulates if doing multiple inserts and clears, and on some subsequent html inserts can affect the inserted data. It tries to stuff the html columns into the existing table structure. In PB 9, everything was cleared out with nothing apparently left behind. But the table was not visible in PB 9, so maybe tables weren't supported.



What seems to be a good workaround is to have the customer use the clearflag set to true on the subsequent html insertdocument. If you do the insertdocuments with the clearflag argument set to true, then it does clear out the table stuff. But the customer is also doing some header and footer inserts, and this no longer works when the clearflag is set to true. So this is not an acceptable workaround for the customer.



The customer wants the RTE.Clear() to clear out the text and table structure and let subsequent insertdocuments and header and footer inserts work properly.



July 17, 2009: Engineering can't fix the clear() problem in an EBF, however they were able to fix the workaround. Verified the workaround using InsertDocument() with the clearflag argument set to true to true is fixed in PB 11.5.1 build 4556.



CR:576682
CR Number:   576682
Product Name:   PB Enterprise
Product Component:   PB.NET WebForm
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
The customer would like to lock down the left most columns in a grid style datawindow and to do this in Powerbuilder he would use the HorizontalScrollSplit functionality. Unfortunately this isn't supported in Powerbuilder 11.5 WebForms. Customer is requesting this functionality be incorporated into the PowerBuilder Webforms functionality.



CR:576864
CR Number:   576864
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
A right aligned italic TrueType fonts can be cut-off at the right of a DataWindow column or control.



CR:576905
CR Number:   576905
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
30 Jun 2009 Not a Bug
Description
The customer is running PB on a 64 bit Windows 2008 machine. They are setting the printer driver in a datawindow using the datawindow.printer property. They are noticing a much longer time to retrieve the datawindow when the printer they set is a networked printer driver especially the Easy Print 32 bit driver (Windows Terminal Services printer service). The issue is only with composite reports which are always displayed in Print Preview mode. When using a standard printer driver, a report print preview shows up on the screen in about 4 seconds. The same report takes about 1-2 minutes when using the Easy Print driver.



Testing here on Windows XP with a local printer vs a networked printer does consistently show that with the networked printer set in the datawindow.printer property, the retrieve takes longer in a good 9 out of 10 retrieves. This difference is magnified on the customer's environment.
Workaround Description
 Don't set anything (or set the fastest local printer) in the datawindow.printer property during retrieves. Only set a printer just before an actual print, and remove it afterward.



CR:576927
CR Number:   576927
Product Name:   PB Enterprise
Product Component:   ORCA
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
19 Jun 2009 Fixed
13 Jul 2009 Fixed
Description
Customer is claiming that



#if defined PBNATIVE then



is always evaluating as false when used with Orca.



CR:577074
CR Number:   577074
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11.5 07 Sep 2009 Fixed
Description
To solve the length limitation problem, engineering needs to research input lob locator binding, then we can sent a lob to server side(not a string or binary data mapped to oracle long or long raw, which has length limitation) . Current we only support output lob locator binding(server send a lob data to client).



CR:577088
CR Number:   577088
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Nulls are being inserted when using DisableBind = 0.

Powerbuilder 11 and Oracle database.



The customer has a very active application with an Oracle backend. For

performance reasonss he wants to use bind varibles. See http://www.orafaq.com/node/29 for an explanation of how Oracle uses bind varibles.



The customer does a powerbuilder insert with DisableBind = 0. The issue is that "Nulls" are getting inserted into the database for columns where the values in datawindow column are empty. Customer believes that the insert statements should not be inserting null for empty values in the datawindow columns.



CR:577298
CR Number:   577298
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11.2 04 Aug 2009 Fixed
Description
Modify call on Datawindow with no controls crashes in PBSHR dll, it worked fine in previous versions of PB.



CR:577299
CR Number:   577299
Product Name:   PB Enterprise
Product Component:   PB.NET WebForm
Status:   Closed
OS:   Vista
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
16 May 2011 Fixed
27 Aug 2010 Fixed
Description
Vista font (eg. cambria) in contemporary menu has display problem in webform. The menu text will display in bold and scrambled when hovering the mouse over it. Only on vista.



CR:577303
CR Number:   577303
Product Name:   PB Enterprise
Product Component:   PB.NET WebForm
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
06 Aug 2009 Fixed
03 Sep 2009 Fixed
Description
PrintManger is not showing the Document name

on a WebForm for datastore. It does not show the document name whether the

name was set in the datawindow object or dynamically using dot notation or modify.





It works ok for datawindow but not datastore. Works ok in Winform and PBNative.
Workaround Description
 Customer using a hidden datawindow instead of datastore



CR:577496
CR Number:   577496
Product Name:   PB Enterprise
Product Component:   PB.NET WebForm
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Jul 2009 Fixed
Description
In a .NET Webform application an empty(NULL)row in a DropDownDataWindow is not displayed when expanding the DDDW.



CR:577498
CR Number:   577498
Product Name:   PB Enterprise
Product Component:   PB.NET DW
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
31 Aug 2009 Fixed
31 Aug 2009 Fixed
Description
In a webform application a datawindow with a dropdowndatawindow is placed on a tabcontrol.

When the DDDW is expanded, the DW control gets moved upwards, using PBDataWindowEnableDDDW true.



CR:577527
CR Number:   577527
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Microsoft Windows 2003
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
25 Jun 2009 Fixed
16 Jul 2009 Fixed
Description
OS: Windows 2003

Versions and Build #s Tested: PB 11.5_3127, PBVM 11.5 (that comes with EAServer 6.2 installation )and also PBVM 11.5_3127 upgrade in EAServer side

Database/Driver File/Version: N/A



Comments:

When a JSP invokes a PB NVO that performs intercomponent call to second PB NVO, PBVM 11.5 throws an exception and leads EAServer to crash. The issue happens if intercomponent call invokes a method with datetime datatype in parameter.
Workaround Description
 Replace datetime datatype by string and use PB functions to toggle between datetime/string and vice-versa.



CR:577691
CR Number:   577691
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
23 Feb 2010 Third Party Problem
Description
Orcascript:



When connecting to MS Visual SourceSafe 6.0, 2005 with orcascript the

VSS Password dialog appears eventhough the password was set in the script.



scc set connect property userid "Orca"

scc set connect property password "orca"



CR:577810
CR Number:   577810
Product Name:   PB Enterprise
Product Component:   Rich Text
Status:   Closed
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Aug 2009 Added to user documentation
16 Nov 2009 Fixed
Description
The customer needs to load various text files (generated by Pro*C or Oracle package on

UNIX)into a RichText DataWindow in their PowerBuilder application and then print out the

text files with Landscape Orientation (most of the time) from there. On PB10.2, the long text will be be truncated to display. On PB11.2, the long text file will be word wrapping

to new line, even the RichText DataWindow control has turn of the word wrapping.

After the dw.InsertDocument(), there is no way to reset the word wrapping.



CR:577893
CR Number:   577893
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Aug 2009 Fixed
Description
SetText crashes when strings contains over 130 numeric characters.



CR:578096
CR Number:   578096
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB failed to create EasySoap Proxy with SAP wsdl File with

"Unknown Exception found" in Web Service Proxy Wizard.



CR:578098
CR Number:   578098
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB failed to create EasySoap Proxy with SAP wsdl File with

"Unknown Exception found" in Web Service Proxy Wizard.



CR:578100
CR Number:   578100
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
PB failed to create EasySoap Proxy with SAP wsdl File with

"Unknown Exception found" in Web Service Proxy Wizard.



CR:578102
CR Number:   578102
Product Name:   PB Enterprise
Product Component:   PB Web Services
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
13 Jul 2009 Fixed
Description
PB failed to create EasySoap Proxy with SAP wsdl File with

"Unknown Exception found" in Web Service Proxy Wizard.



CR:578158
CR Number:   578158
Product Name:   PB Enterprise
Product Component:   DB ODBC
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
19 Apr 2010 Not a Bug
Description
Customer is connecting to a SQL Server database with ODBC and when he tries to call a stored procedure and perform an update he is receiving an error,



SQLSTATE = 07006

[Microsoft][ODBC SQL Server Driver]Restricted data type attribute violation



If customer connects using ADO.NET, OLE DB or SNC there is no error. They have used ODBC in the past and say this is a migrated application that did not show the error in PB 9.0.3. The testcase however for me, does show the error in PB 9.0.3 but they insist their actual application does not.



CR:578353
CR Number:   578353
Product Name:   PB Enterprise
Product Component:   Source Control
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
07 Oct 2009 Consult Complete
Description
Opening an object under ClearCase will crash

PB in the IDE.



The crash is happening in the PBLIB115!CFP_Folder::EnumActions



FAULTING_SOURCE_CODE:

242:

243: if (bInWebTarget || bInJSPTarget)

244: {

245: // New...

> 246: hr = LP_CreateNewAction(m_pContext, m_strURL, IID_IPB_Action, (void**)&pIAction);

247: if (SUCCEEDED(hr))

248: {

249: PB_ASSERT(pIAction != NULL);

250: list.AddTail(pIAction);

251: pIAction->Release();



CR:578369
CR Number:   578369
Product Name:   PB Enterprise
Product Component:   Machine Code Exe Creation
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Customer would like a way to create a windows service from their PB exe directly from PowerBuilder.



There are several third party tools available to do this and but he would like to be able to do it without purchasing a third party tool.



http://www.topwizprogramming.com/pbniserv.html



http://www.ecrane.com/pbservice1.cfm



http://www.firedaemon.com/



CR:578566
CR Number:   578566
Product Name:   PB Enterprise
Product Component:   DW Expression
Status:   Open
OS:   Windows XP
Original Version:   12.0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request



Provide properties to specify the sorting order of DataWindow Crosstab Columns



CR:578833
CR Number:   578833
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
The customer runs 80 reports for 3000 customers. So they currently run SPs that return all the data for all customers and use filters and SaveAs on the PB client to generate reports for each customer. They use this approach because if they put the filter on the SP, they would need to run 3000 x 80 reports every evening. They run into problems when the rowcount exceeds the DW size limit. If you run the attached sample using the README instructions and review the log using the enclosed Winvi editor, you'll see blank lines for the last 500K rows.



Customer enhancement is a request for a larger DW size limit.



CR:579165
CR Number:   579165
Product Name:   PB Enterprise
Product Component:   PB.NET WebForm
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
07 Jul 2009 Fixed
06 Aug 2009 Fixed
Description
In PB11.2, the toolbar icons in dynamic menu items work fine with the IE WebControls but not with Telerik RadControls (the standard with PB IDE 11.5)
Workaround Description
 as a workaround ct moved from dynamic to static menus in toolbars.



CR:579189
CR Number:   579189
Product Name:   PB Enterprise
Product Component:   Window - Runtime
Status:   Open
OS:   Windows XP
Original Version:   12.0
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Enhancement Request for full (png picture) transparency support including z-order.



CR:579206
CR Number:   579206
Product Name:   PB Enterprise
Product Component:   System Runtime Functions
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
03 Jul 2009 Fixed
05 Aug 2009 Fixed
Description
Ct needs to import XML files in DataWindows, which have whitespaces as content. The DataWindow functions importFile() and importString() don't work with these files correctly, because they drop rows and columns.



CR:579217
CR Number:   579217
Product Name:   PB Enterprise
Product Component:   DW XML
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
03 Aug 2009 Fixed
Description
When you import a XML file into a DataWindow using an XML template, you will get incorrect results :

- Some values are not in the right column

- Some values are not imported



CR:579225
CR Number:   579225
Product Name:   PB Enterprise
Product Component:   Language - Compiler
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
10 Jul 2009 Fixed
30 Jul 2009 Fixed
Description
PB is crashing at compile time of a global function. The customer has a global function and in the function, the customer is attempting to set an initial value to the integer variable minute_pos when declaring it. But they are using an expression that can only be evaluated at runtime:



int minute_pos = pos(time_value,':')



where time_value is an argument passed into the function at runtime. Declarations happen at compile time, and time_value has no meaning or value at compile time. The expression pos(time_value,':') clearly is intended to be evaluated at runtime using the passed in time_value to the function, so it makes no sense to use the syntax to set an initial value to the variable in a declare statement. Even if it could compile this one line declare statement will never be executed at runtime. The correct syntax is the commented out 2 lines:



int minute_pos // Declare the variable at compile time

minute_pos = pos(time_value,':') // Set a value at runtime when the function is called.



This is from the Help on initial values for variables: "Although you can use global system functions or expressions to initialize variables with compile time values in a variable declaration statement, for runtime value assignments, you must declare variables and assign their values in separate statements."



So the issue here for Engineering is can we aviod the crash and get a compile time error message?



07/15/2009: Verified fixed in PB 11.5.1 EBF build 4556 and after.



CR:579399
CR Number:   579399
Product Name:   PB Enterprise
Product Component:   Rich Text
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
29 Jul 2009 Fixed
Description
A regression since 11.5 GA. The customer is doing an InsertDocument of an HTML file into an RTE control. Now there are 3 funcky characters visible in the front of the document. The file is encoded ansi and there is no BOM. These characters did not show up in PB 11.5 GA.



July 17, 2009: Verified fixed in PB 11.5.1 build 4556.



CR:579422
CR Number:   579422
Product Name:   PB Enterprise
Product Component:   DB SQLAnywhere
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
26 Jul 2009 Fixed
Description
Customer is in Infomaker 11.5. He has datawindows (reports) that now take a very long time to open the SQL Painter (Clicking DataSource). Some reports take minutes before the SQL appears. In PB 9.0.3 it displays the SQL very quickly connected to the exact same database and opening the same report. Why is this taking so long now? Can something be fixed in 11.5 to make this quicker?



The database is SQL Anywhere 11 and ODBC is used to connect.



July 17, 2009: Verified fixed in PB 11.5.1 build 4556 and after.



CR:579592
CR Number:   579592
Product Name:   PB Enterprise
Product Component:   DW Display
Status:   Open
OS:   Windows XP
Original Version:   11.2
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Description of Problem:



From the only help for 11.2 and 11.5, it states for 'Using number display formats' that

'These keywords tell PowerBuilder to determine an appropriate format based on system

settings'



[General]

[Currency]



From the online documentation for PB 11.2 and PB 11.5, Users Guide, Chapter 22: Displaying and Validating Data for

Number keywords 'You can use the following keywords as number display formats when you want PowerBuilder to determine an appropriate format to use'.



The online documentation does not reference that {General] and [Currency] are

based on system settings. The online documentation does not appear to be in sync

with the online help.



CR:579807
CR Number:   579807
Product Name:   PocketBuilder
Product Component:   DB Painter
Status:   Open
OS:   Windows XP
Original Version:   2.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Not a Bug
Description
The Ultralite UL10 DB interface shows datatypes differently than they actually are, eg. varchar(n) is displayed as char(n)and DateTime is displayed as Timestamp.



CR:579811
CR Number:   579811
Product Name:   PocketBuilder
Product Component:   DB Painter
Status:   Closed
OS:   Windows XP
Original Version:   2.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
08 Dec 2009 Fixed
Description
The Ultralite UL10 DB interface does not show a primary key created with constraint as primary key, it will show as index.



CR:580170
CR Number:   580170
Product Name:   PB Enterprise
Product Component:   PB.NET DW
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
28 Mar 2010 Fixed
Description
Webform: Entered text disappears



On a .Net Webform application when setting the DataWindow Visible property to False and

back to True again, the last entered text may have dissappeared from the dataWindow.



Note:

There are other options to hide a DataWindow like setting the x or y coordinate to a large negative value.



CR:580176
CR Number:   580176
Product Name:   PB Enterprise
Product Component:   DW - Runtime
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
04 Aug 2009 Fixed
Description
The customer has a datawindow sort criteria that used PB functions like:



"abs(col1) A,abs(col2) A"



If he takes this exact string though, and does a SetSort to the datawindow the setsort adds a space after the comma and the sort string becomes:



"abs(col1) A, abs(col2) A"



The cusotmer does a lot of iterations of this in his app. The extra spaces add up and become a problem, using memory and eventually crashing PB. Not a problem if the functions are not in the sort string.



July 17, 2009: Verified fixed in PB 11.5.1 build 4556 and after.



CR:580459
CR Number:   580459
Product Name:   PB Enterprise
Product Component:   Jaguar Integration
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
22 Jul 2009 Not a Bug
Description
Using Jaguar thread manager, can not start the thread



CR:580544
CR Number:   580544
Product Name:   PB Enterprise
Product Component:   DB Oracle
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11.2 30 Jul 2009 Fixed
Description
After calling SyntaxFromSql, the retrieve on a datastore fails but works on second call and after.



The problem occurs on some conditions : The PbCatalogOwner is set in the dbparm and the user connected is not the owner Pb catalog tables.



CR:580775
CR Number:   580775
Product Name:   PB Enterprise
Product Component:   DW XML
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
03 Aug 2009 Fixed
Description
The customer has a datawindow with an XML export template defined that has the encoding set to UTF-8. The Export Use Template is set to this UTF-8 template. Yet when they use dot notation to get the xml from the datawindow, dw.object.DataWindow.Data.XML. The XML returned has the default UTF-16LE as the encoding. If you do a SaveAs XML! then it does have the correct UTF-8 encoding in the generated XML file. Even if you set the export use template in script with:



dw_1.Object.DataWindow.Export.XML.UseTemplate='t_request_response'



Before the dw.object.DataWindow.Data.XML, you still get UTF-16LE as the encoding rather than the UTF-8 encoding specified by the template.



CR:580960
CR Number:   580960
Product Name:   PB Enterprise
Product Component:   DB MS SQLServer
Status:   Closed
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
11.5 17 Nov 2009 Fixed
24 May 2010 Fixed
Description
SqlServer Native Client (SNC)incorrect generation -exec sp_executesql- with index columns data type Varchar().

The problem involves the nvarchar and varchar types trought SNC with SQL Server 2008 and disableBind=0

With DisableBind=1 or with another mode of connection, ODBC , OLEDB, all works fine
Workaround Description
 Use DisableBind=1 or another connection like ODBC , OLEDB



CR:581034
CR Number:   581034
Product Name:   PB Enterprise
Product Component:   DW Edit Mask
Status:   Open
OS:   Windows XP
Original Version:   11.5
Fixed Version Build Resolution Date Closure Code (If Appropriate)
Description
Ability to use [currency] or [general] to set the Display Format

for Rupees.



This is a continuation of cr566072. Currently to display ruppees

in the dw, you must set the Display Format to ##,##,##,###.00. The customer

feels that it should be reading the regional settings. If so, then you

should be able to just use [currency] or [general].



Our documentation states that you can use the following keywords as number display

formats when you want PowerBuilder to determine an appropriate format to use:

[General]

[Currency]





--------------------------------------华丽的分割线-------------------------------------------------------------------------

Sybase SQL Anywhere数据库恢复工具ReadASADB:

之前就已经研发成功了能够从Sybase SQL Anywhere的DB文件中恢复数据的工具: ReadASADB。
此工具支持ASA v5.0, v6.0, v7.0, v8.0, v9.0, v10.0, v11.0, v12.0, v16.0, v17.0等版本。
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具。
恢复Sybase SQL Anywhere的工具在国内处于领先水平。

Sybase SQL Anywhere数据库恢复工具ReadASADB功能
能够从损坏的SQL Anywhere数据文件(.db)和UltraLite数据文件(.udb)上提取数据的非常规恢复工具
  1. 适用于所有的SQL Anywhere版本    包括:5.x,6.x,7.x,8.x,9.x,10.x,11.x,12.x,16.x,17.x
  2. 适用于所有的UltraLite版本
  3. 能够恢复出来表结构和数据
  4. 能够恢复自定义数据类型
  5. 能够恢复存储过程等对象的语法
  6. 能够导出到目标数据库
  7. 能够导出到SQL文件并生成导入脚本
  8. 支持多种字符集,包括:cp850、cp936、gb18030、utf8等
  9. 能够恢复未加密或者简单加密类型的数据
  10. 简单易用
  11. 限制:不支持AES加密的数据文件
请参考:研发成功了从Sybase SQL Anywhere的DB文件上恢复数据的工具
            SQL Anywhere数据库非常规恢复工具ReadASADB使用介绍

Sybase SQL Anywhere数据库恢复工具ReadASADB适用场景

各种误操作:

  1. 误截断表(truncate table)
  2. 误删除表(drop table)
  3. 错误的where条件误删数据
  4. 误删除db或log文件
  5. 误删除表中的字段

Sybase SQL Anywhere数据库恢复工具ReadASADB的应用场景:

1.因为物理磁盘故障、操作系统、系统软件方面或者掉电等等原因导致的Sybase SQL Anywhere数据库无法打开的情况;
2.误操作,包括truncate table,drop table,不正确的where条件导致的误删除等;
Sybase SQL Anywhere无法打开时,比较常见的错误是:Assertion failed。
如:
1、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Checkpoint log: invalid bitmap page -- transaction rolled back
2、Internal database error *** ERROR *** Assertion failed:201819 (8.0.1.2600) Page number on page does not match page requested -- transaction rolled back
3、Internal database error *** ERROR *** Assertion failed:200502 (9.0.2.2451) Checksum failure on page 23 -- transaction rolled back
4、File is shorter than expected
5、Internal database error *** ERROR *** Assertion failed: 201116 Invalid free list index page found while processing checkpoint log -- transaction rolled back
6、*** ERROR *** Assertion failed: 51901 Page for requested record not a table page or record not present on page
7、*** ERROR *** Assertion failed: 201417 (7.0.4.3541) Invalid count or free space offset detected on a table page
8、Internal database error *** ERROR *** Assertion failed: 201425 (8.0.3.5594) Invalid count or free space offset detected on a free list page -- transaction rolled back.
9、Internal database error *** ERROR *** Assertion failed: 100702 (8.0.1.2600) Unable to modify indexes for a row referenced in rollback log -- transaction rolled back


-------------------------------------------------------------------------------------------

Sybase ASE数据库恢复工具READSYBDEVICE:

一个不依赖数据库管理系统、直接从Sybase数据库设备文件上提取数据的业内领先的恢复工具!
能够从损坏的Sybase ASE设备文件(.dat)上提取数据的非常规恢复工具。

Sybase ASE数据库恢复工具READSYBDEVICE的主要功能:

  1. 被勒索病毒加密数据文件及备份文件情况下的恢复;
  2. 系统崩溃只剩下数据文件的情况下的恢复,甚至数据库文件不存在而只有损坏的备份文件情况下的恢复;
  3. 因断电、硬盘坏道等造成数据库文件损坏情况下的恢复;
  4. delete数据恢复、误update数据恢复、误删除表(drop)恢复、误truncate表恢复 等;
  5. 各种Sybase内部系统表损坏、索引错误的修复;
  6. master数据库损坏而无法正常运行情况下的恢复;
  7. Sybase数据库被标记为可疑,不可用等情况的恢复;
  8. Sybase数据库中数据文件内部出现坏块情况下的恢复;
  9. Sybase数据库无数据文件但有日志文件的情况下的恢复;
  10. Sybase数据库只有数据文件无任何日志文件的情况下的恢复;
  11. Sybase数据文件被误删除情况下的碎片提取恢复;
  12. 磁盘阵列上的Sybase数据库被误格式化情况下的数据库恢复;
  13. 数据库sysobjects等系统表损坏无法正常应用情况下的恢复;
  14. Sybase数据库还原数据库出现失败情况下的恢复;
  15. Sybase数据库只剩下损坏的备份文件情况下的恢复。

Sybase ASE数据库恢复工具READSYBDEVICE支持的版本:

Sybase ASE 11.0.x,11.5.x,11.9.x,12.0.x,12.5.x,15.0.x,15.5.x,15.7.x,16.0.x


-------------------------------------------------------------------------------------------

SQL Server数据库恢复工具SQLRescue:

一个不依赖数据库管理系统、直接从SQL Server数据库文件上提取数据的业内领先的恢复工具!
能够从损坏的SQL Server数据库文件(.mdf)上提取数据的非常规恢复工具。

SQL Server数据库恢复工具SQLRescue的主要功能:

  1. 系统崩溃只剩下数据文件的情况下的恢复,即无日志文件或者日志文件损坏情况下的恢复;
  2. 断电导致数据库文件损坏情况下的恢复;
  3. 硬盘坏道造成数据库损坏情况下的恢复;
  4. 数据文件内部存在坏页情况下的恢复;
  5. 企业管理器误删除数据表记录,管理软件误删除数据表记录的恢复;
  6. 并闩锁错误、格式化、误删除后导致软件不能使用的情况;
  7. 无法读取并闩锁页sysindexes失败情况下的修复;
  8. 数据文件被误删除情况下的碎片提取恢复;
  9. 系统表损坏、索引错误、误删除数据库表、删除记录的数据找回;
  10. master数据库损坏而无法正常运行情况下的恢复;
  11. 数据文件无法附加情况下的数据恢复;
  12. 数据库被标记为可疑,质疑,不可用等情况的恢复;
  13. 数据库sysobjects等系统表损坏情况下的恢复;
  14. 数据被误(drop、delete、truncate)删除表数据的恢复,误update后的数据恢复等;
  15. 还原时报一致性错误,错误823等情况下的数据恢复,各种错误提示的数据库文件修复;
  16. 数据库被误格式化等情况下的数据库恢复;
  17. 日志收缩造成数据库损坏情况下的恢复;
  18. 仅剩损坏的备份文件情况下的恢复。

SQL Server数据库恢复工具SQLRescue技术特点:

只要SQL Server数据库的数据文件存在,我们就有办法帮您从数据文件中找回重要数据。
  1. 从数据文件中直接恢复数据
  2. 不能附加时直接恢复数据并生成新的数据库
  3. 系统表损坏的数据库修复
  4. 快速修复SQL 823错误、连接中断错误

SQL Server数据库恢复工具SQLRescue支持的版本:

Microsoft SQL Server 7.0, 2000, 2005, 2008, 2008R2, 2012, 2014, 2016, 2017,2019。
+-------------------------------------华丽的分割线-------------------------------------------------------------------------